Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"lap length"”
-
The effects of casting position and bar shape on the lap length of plain bars in concrete
… investigation to study the behaviour of lap spliced plain steel bars in reinforced concrete specimens. Three of the specimens were instrumented with strain gauges adhered to the reinforcement and the concrete side face. Three lap splice lengths, two bar sizes for square bars, and one bar …
-
High cycle (fatigue) resistance of reinforced concrete beams with lap splices
… for reinforced concrete beams containing lap splices has been mainly aimed at preventing failures due to static (monotonic) loading, or low cycle, high intensity (seismic) loading. However, little consideration has been given in these standards or in previous research to the performance of …
-
Structural Behaviour of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes
Lapped joints of cold-formed steel (CFS) Z-shaped purlins are extensively used in metal building roof systems. The research that has been carried out so far for these lapped connections is primarily focused on connections with round holes. However, the lapped connections with vertical slotted holes …
-
Experimental Investigation of Reinforced Concrete Beams with Lapped Reinforcement
… which was tested in various spacing and lap lengths. The second type of joint was welded wire reinforcement with varying wire spacing. In order to accelerate bridge construction, it is desirable to narrow the width of the jointed zone. However, the width has to be wide enough to …
-
Comportamento experimental e numérico de bioconcretos de madeira e de painéis sanduíches com faces em laminados reforçados por fibras longas de sisal
… laws. Because of the sisal fiber maximum length limitation when an element of length higher than 1.5 meters is projected, fibers overlapping had been studied with lap lengths of 0, 25, 50 and 75 mm. The three-point bending test results of the laminates reinforced by unidirectional sisal …
-
Non-Contact Lap-Splice Design with Ultra-High-Performance-Concrete for Seismic Buildings
… explores a controllable slippage mechanism in lap-splice configurations of monolithic ultra-high performance concrete (UHPC) members to regulate the location and capacity of plastic hinges in concrete building frames. UHPC's superior tensile, compressive, and bond strengths, compared to normal …
-
Load-settlement and stress-strain behaviour of geotextile-reinforced sandy soil
… width occupied by the reinforcement, and the lap length of the wrapped ends, based on numerical modelling, (iii) present experimental evaluations of the effectiveness of the wraparound reinforcement technique for improving the bearing capacity and load-settlement characteristics of sandy …
-
Hooked Bar Anchorages and their Use in Noncontact Lap Splices
Lap splices are used in reinforced concrete structures to transfer tension forces across discontinuous reinforcing bars to allow for continuity of load path in structural elements. Lap splices of straight reinforcing bars present a number of disadvantages when used in connections of large precast …
-
Reinforcing Bar Splice Performance in Masonry with Self-Consolidating Grout
… reinforcing bars were constructed with splice lengths as prescribed by the current design equation and splices that were slightly shorter. Test Group 1 consisted of six reinforced masonry panels with the code required lap length while Test Groups 2 and 3 had splices two and four inches shorter, …
-
Shear strengthening of reinforced concrete beams with significant corroded stirrups using high-strength strain hardening cementitious composites (HS-SHCC)
… <p>The conventional repair method is to lap additional rebar to the corroded reinforcement, which is time-consuming and uneconomical due to high labor costs. In some cases, due to limited depth of the member, there is insufficient lap length for stress transfer from corroded stirrup to …
-
Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction
… on average, the reinforcing bars in non-contact lap splices, where the lapped bars are located in adjacent cells, only develop 71% of the tensile resistance of spliced bars which are in contact. An experimental program was therefore initiated to design and evaluate remedial measures which can …
-
ANCHORAGE OF HEADED REINFORCING BARS IN CONCRETE
… reinforcement in the plane of the slab, and six lapped-slplice specimens without confining reinforcement containing No. 6 headed bars and an analysis of these tests along with test results from 23 studies by other researchers of 84 exterior, seven roof-level interior, and seven knee beam-column …
-
Endverankerung und Übergreifung textiler Bewehrungen in Betonmatrices
Die sichere Einleitung und Übertragung der wirkenden Kräfte ist Bedingung für die Funktionsfähigkeit und die vollständige Ausnutzung der Tragfähigkeit von Textilbetonbauteilen und -verstärkungsschichten. So kann es bei ungünstiger Konfiguration und Anordnung der Einzelkomponenten des …
-
Load-settlement investigation of geosynthetic-reinforced soil using experimental, analytical, and intelligent modelling techniques
… such as number of layers, reinforcement width, lap-length ratio and planar width of wraparound, were investigated, and their potential effect on the load-settlement behaviour has been studied. The wraparound reinforced model has shown about 45% lower average total settlement than the …