Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"laser safety"”.

  1. Rochester Institute of Technology's Laser Safety Manual

    Rochester Institute of Technology's Laser Safety Manual and Training Guide have been created as a recommended safety manual and training guide to help laser users work with lasers and laser systems in a safe manner. Standard operating procedures and protocols have been provided in order to assist …

    rit Repository record for Rochester Institute of Technology's Laser Safety Manual (opens in a new tab)

  2. Sum Frequency Generation in Laser Safety and Quantum Telecommunications Applications

    … implications of sum-frequency generation in both laser safety and quantum telecommunications applications. Green laser pointer technology uses frequency doubling of invisible 1064 nm infrared radiation to visible 532 nm green radiation. An inexpensive green laser pointer was found to emit infrared …

    maryland Repository record for Sum Frequency Generation in Laser Safety and Quantum Telecommunications Applications (opens in a new tab)

  3. Temperature increase measurements of multiple 10 ms pulses of 2.01 μm laser light incident on ex-vivo rabbit corneas

    Current laser safety standards for multiple-pulse lasers are based primarily on modeling and the results of single-pulse studies. Previous thermal effects studies have focused on histological and visible endpoints, with only a few studies examining the actual temperatures achieved. The goal of this …

    colostate Repository record for Temperature increase measurements of multiple 10 ms pulses of 2.01 μm laser light incident on ex-vivo rabbit corneas (opens in a new tab)

  4. Laser damage thresholds of ex-vivo pig and rabbit corneas at 2.5 and 2.7 μm with 8 nanosecond laser pulse duration

    With the rapid development of advanced laser technology, lasers have been widely applied to research, industry, medicine, military, and consumer products, particularly in the infrared (IR) spectral region. Consequently, safety has been a major concern not only for people who develop and operate …

    colostate Repository record for Laser damage thresholds of ex-vivo pig and rabbit corneas at 2.5 and 2.7 μm with 8 nanosecond laser pulse duration (opens in a new tab)

  5. Development of a LIDAR for integration with the Naval Postgraduate School Infrared Search and Target Designation (NPS-IRSTD) system

    … The lidar used a frequency-doubled Nd:YAG laser which had an energy output of 2 millijoules. The laser beam was expanded to 17.75 inches using a Dall-Kirkham telescope to operate within laser safety limitations. The theoretical analysis of the 'Klett' method for the inversion of lidar …

    nps Repository record for Development of a LIDAR for integration with the Naval Postgraduate School Infrared Search and Target Designation (NPS-IRSTD) system (opens in a new tab)

  6. Free space optics communication for mobile military platforms

    … precision, line-of-sight obstructions, and laser safety are also studied. A final section will look at the acquisition, pointing, and tracking mechanisms that are necessary for deploying FSO on mobile platforms.

    nps Repository record for Free space optics communication for mobile military platforms (opens in a new tab)

  7. The Integration and Validation of a Class 3B Laser for Stereo Particle Imaging Velocimetry

    Particle Imaging Velocimetry (PIV) is a laser flow diagnostic measurement technique used to measure spatial and temporal velocity fields. In an effort to promote experimental aerodynamic research, specifically an entry point for students to learn Particle Imaging Velocimetry, an in-house Class 3B …

    calpoly Repository record for The Integration and Validation of a Class 3B Laser for Stereo Particle Imaging Velocimetry (opens in a new tab)

  8. Using a Single Neural Network for Simultaneous Noise Reduction and Layer Segmentation in Visible Light Optical Coherence Tomography of human retina

    … However, due to the practical limitation of laser safety and comfort, the permissible illumination power is much lower than NIR OCT which can be challenging to obtain high quality VIS-OCT images and subsequent image analysis particularly in pathological eyes. Therefore, improving VIS-OCT …

    jhu Repository record for Using a Single Neural Network for Simultaneous Noise Reduction and Layer Segmentation in Visible Light Optical Coherence Tomography of human retina (opens in a new tab)

  9. From Machine Enclosure to Pressurised Build Chamber - Enabling Additive Manufacturing of Large Components in Inert Environments

    … becomes increasingly challenging. Permanova Lasersystem AB is developing a scaled up laser directed energy deposition (L-DED) system with a larger and reversible build plate to enable larger and more efficient builds and improved residual stress control. However, the current tent-based inert …

    chalmers Repository record for From Machine Enclosure to Pressurised Build Chamber - Enabling Additive Manufacturing of Large Components in Inert Environments (opens in a new tab)

  10. Empirical Safety Assessment of 30 mJ Laser Energy at 750 nm Laser Wavelength for Photoacoustic-Guided Liver Surgeries

    … are difficult to differentiate within current safety limits, which only exist for human skin and eyes. This thesis contains a preliminary investigation of the safety of raising this limit for liver tissue with the broader benefit of enhanced image quality for photoacoustic-based surgical …

    jhu Repository record for Empirical Safety Assessment of 30 mJ Laser Energy at 750 nm Laser Wavelength for Photoacoustic-Guided Liver Surgeries (opens in a new tab)

  11. Optical-Resolution Photoacoustic Microscopy

    … system configuration, experimental procedures, laser safety, functional imaging scheme, and example biomedical applications at a variety of in vivo anatomical sites: i.e., skins, eyes and brains). The second part of my dissertation focuses on the application of OR-PAM in vascular biology, with …

    wustl Repository record for Optical-Resolution Photoacoustic Microscopy (opens in a new tab)

  12. Nanomaterial-loaded contact lenses for treating anterior segment ophthalmic diseases

    … the feasibility of utilizing GoldinLenses for laser protection (532 nm) due to the existence of gold nanoparticles. Gold nanoparticles absorb the radiation, which provide a superior laser protection efficacy, compared with the commercial laser safety glasses (around 50\%). Besides, the absorbed …

    colo-mines Repository record for Nanomaterial-loaded contact lenses for treating anterior segment ophthalmic diseases (opens in a new tab)

  13. Development of a Portable In Vivo Confocal Ophthalmoscope (PICO) for Non-Contact Corneal Imaging

    … analysis studies against the ISO and ANSI laser safety standards were conducted to ensure safe use of the device on human subjects. Collectively, these results establish the technical foundation for translating PICO into a clinically deployable diagnostic tool. Chapter 2 introduces the …

    arizona-thes Repository record for Development of a Portable In Vivo Confocal Ophthalmoscope (PICO) for Non-Contact Corneal Imaging (opens in a new tab)

  14. Applications of Light for Biomaterials and Safety

    … area of research. Recent expansion of ultrafast laser sources in the midinfrared (MIR) regime is driving research in previously unexplored areas. In particular, the applications of these systems to biological materials is significant due to biological materials response to MIR wavelengths. The …

    tamu Repository record for Applications of Light for Biomaterials and Safety (opens in a new tab)

  15. Co-registered photoacoustic and ultrasound tomographic imaging of human colorectal and ovarian cancer: light delivery, system development, and clinical study

    … exposure (MPE), while enabling higher laser energy injection to enhance the photoacoustic (PA) signal generated from the tissue. Third, we proposed an improved beamformer, named lag-based delay multiply and sum combined with coherence factor (DMAS-LAG-CF). Simulations and phantom …

    wustl Repository record for Co-registered photoacoustic and ultrasound tomographic imaging of human colorectal and ovarian cancer: light delivery, system development, and clinical study (opens in a new tab)

  16. Řízený laserový zdroj pro plašení ptactva

    … plašení ptáků a jejich humánního plašení pomocí laserů. Práce také pojednává o bezpečnosti laserů, problému řídicího obvodu laserových diod, kolimaci svazku a jeho rozšíření tak, aby výstupní výkon paprsku nepřekročil maximální hodnotu výstupního výkonu laseru třídy 2M.

    brno-tech Repository record for Řízený laserový zdroj pro plašení ptactva (opens in a new tab)