Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 221 for “"lateral resolution"”.
-
Null subtraction imaging technique for biomedical ultrasound imaging
In ultrasonic imaging, reduction of lateral sidelobes results in an improved image with less distortion and fewer artifacts. In general, apodization is used to lower sidelobes in exchange for increasing the width of the mainlobe and thus decreasing lateral resolution. Null subtraction imaging (NSI) …
-
Gabor Domain Optical Coherence Microscopy
… community has concentrated on improving axial resolution through the development of broadband sources and speed of image acquisition through new techniques such as Spectral domain OCT (SD-OCT). In SD-OCT, an entire depth scan is acquired at once with a low numerical aperture (NA) objective lens …
-
BIJECTIVE ILLUMINATION COLLECTION IMAGING: HIGHRE-SOLUTION TOMOGRAPHY IN THREE DIMENSIONS
High-resolution optical imaging in three imensions from sub-surface of the issues enables numerous biological studies and clinical applications. High-resolution images are conventionally achieved by tight focusing of light into one point. Dictated by diffraction, tightly focused light spreads …
-
Evaluation of null subtraction imaging and interpolation techniques for ultrasound B-mode
… many attempts have been made to improve the lateral resolution through various adaptive and non-adaptive techniques. While each technique has its advantages and disadvantages, there are some challenges common to all methods. In particular, improvements in lateral resolution are often …
-
Novel techniques of optical detection and observation of periodic crystals
… periodic crystals with truly high lateral resolution at visible frequencies using some of the contemporary techniques. The Plasmonic and Non-plasmonic Ultra-Thin optical condensers based on illumination of object using evanescent surface waves that can be resonantly coupled to …
-
Modeling and Estimation of the Volume of Interaction of an Electrostatic Force Microscope Probe with a Dielectric Sample
… to estimate the volume of interaction and the lateral resolution of this technique. The volume of interaction was estimated at 6000 μm3 and the lateral resolution was estimated at 10 μm.
-
Mueller Matrix Confocal Scanning Laser Polarimetry and Optimal Conditions for Improved Image Quality
… the aging population. Furthermore, since optical resolution due to diffraction becomes better with increasing pupil size, whereas that due to aberrations becomes worse, the optimal pupil size for best lateral resolution as a function of age had to be determined. Eye models incorporating …
-
Extreme ultraviolet time-of-flight mass spectrometry for the characterization of actinides
… are highly sensitive and have sub-micron spatial resolution. Laser ablation mass spectrometry meets both of these requirements and as such is broadly used for chemical analyses and chemical mapping of atomic and molecular species on solid samples. This thesis describes results on the …
-
Frequency Content Evaluation, Surface-wave Analysis, And Deep Learning Denoising In Low-frequency Seismic Field Data: A Study From Hussar, Alberta
… source-receiver combinations and improving lateral resolution in 2-D shear velocity (Vs) models. To enhance signal coherence in the survey data, we use deep learning techniques to attenuate repetitive coherent signals emitted by pumpjacks, which are challenging to suppress using conventional …
-
Powell Lens-based Line-Scan Spectral Domain Optical Coherence Tomography for Cellular Resolution Imaging of Biological Tissues
… use of cylindrical lenses. It achieves a lateral resolution of <2.1 microns and ~4.1 microns in the x and y directions and an axial resolution of ~1.5 microns in tissue.
-
Line-Scan Spectral-Domain Optical Coherence Tomography for Cellular Resolution Structural and Vascular Imaging of Biological Tissues
… of OCT for in-vivo volumetric cellular resolution imaging of the human anterior eye is challenging due to artifacts induced by involuntary eye motion and the contradictory requirements for high lateral resolution and extended depth of focus. This thesis addresses these challenges by …
-
Extended Focus Range High Resolution Endoscopic Optical Coherence Tomography
… over time to achieve the highest possible resolution, speed of image acquisition, sensitivity, and specificity. In the past decade, advances in optics, fiber, as well as laser technology have enabled the development of noninvasive optical biomedical imaging technology that can also be …
-
Submicron-resolution Photoacoustic Microscopy of Endogenous Light-absorbing Biomolecules
… modalities of photoacoustic imaging, optical-resolution photoacoustic microscopy (OR-PAM) can achieve high spatial resolution, on the order of optical wavelength, at <1 mm depth in biological tissue (the optical ballistic regime). OR-PAM has been applied successfully to structural and …
-
Deep structure ultrasound imaging using fundamental and third harmonic coded excitation techniques
… fundamental and third harmonic 1, 3 chirps with resolution enhancement compression (REC) and frequency compounding, increases the axial resolution, lateral resolution, penetration depth and the contrast-to-noise ratio (CNR) for an ultrasonic imaging system. The thickness mode of piezoelectric …
-
Spinning disk structured illumination microscopy
Among various super-resolution techniques, structured illumination microscopy (SIM) is the most suitable method for live-cell imaging owing to its high speed and low phototoxicity. However, the adoption of SIM faces challenges because of its technical limitations, such as reconstruction artifacts, …
-
Development of Multi-modal Optical Coherence Tomography Imaging Systems and Probes
… biological research for its non-invasive, high-resolution, and depth-resolved properties. Additionally, OCT has demonstrated remarkable versatility in various applications. In this thesis, we develop multi-modal OCT systems. We have designed and built a new class of endoscopic OCT that enables …
-
Applying secondary ion mass spectrometry to cellular and model membranes to image component distribution and quantify composition
… lipids in the cellular membrane using high-resolution SIMS performed with a NanoSIMS. Further, the spatial statistical analysis tools are outlined and applied to NanoSIMS data to test the hypothesis of colocalization of the flu virus protein hemagglutinin and sphingolipids. While the …
-
Making Integrated Terahertz Imaging a Reality
… include: high data-rate, communication, high-resolution imaging radar and spectroscopy. Among these, imaging radars are developed as a reliable and cheap measurement technique for short-range remote sensing applications. Terahertz radiation has several distinct advantages over other …
-
Time Domain Optical Coherence Tomography (OCT) for MEMS-based Endoscopic Application
… endoscope remains attractive due to its high resolution, capability of subepithelial morphology imaging, compact size and low cost of system. Recently, a MEMS-based endoscope scanner is demonstrated to have the ability of focus-tracking and 2D lateral scanning. A time-domain OCT employing …
-
Time Domain Optical Coherence Tomography (OCT) for MEMS-based Endoscopic Application
… endoscope remains attractive due to its high resolution, capability of subepithelial morphology imaging, compact size and low cost of system. Recently, a MEMS-based endoscope scanner is demonstrated to have the ability of focus-tracking and 2D lateral scanning. A time-domain OCT employing …
Page 1 of 12