Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 5 of 5 for “"lateral scatter"”

  1. Dosimetric Validation of an Electron Monte Carlo (eMC) Algorithm for Small Cutouts and Extended SSD’s: Assessing eMC in Small Field Dosimetry

    … dose distributions, validating challenges due to lateral scatter disequilibrium and extended air gaps. Our findings provide systematic data for eMC dose calculations and demonstrate that eMC performs within clinical tolerances, with the ultimate goal of enhancing the precision and safety of …

    vcu Repository record for Dosimetric Validation of an Electron Monte Carlo (eMC) Algorithm for Small Cutouts and Extended SSD’s: Assessing eMC in Small Field Dosimetry (opens in a new tab)

  2. Reduction of Dose Calculation Errors For Patients With Metal Implants Receiving Photon Radiation Therapy

    … as they better model photon interactions and scatter in metals than water-based kernels, while CT metal artifact reduction methods have the potential to decrease calculation errors associated with imaging artifacts. In this work, several metal-based energy deposition kernels (titanium, silver, …

    uthsc Repository record for Reduction of Dose Calculation Errors For Patients With Metal Implants Receiving Photon Radiation Therapy (opens in a new tab)

  3. Υπολογιστική δοσιμετρία σε απλές και ανθρωπόμορφες γεωμετρίες για τη μελέτη της επίδρασης ανομοιογενειών σε διαφορετικά κλινικά διαθέσιμα συστήματα MR-linacs

    … Return effect), ESE (Electron Stream Effect) και lateral scatter ERE, είναι γνωστά για τις μεταβολές που προκαλούν στις κατανομές δόσεων, και αποτελούν κομμάτι της διερεύνησης της παρούσας μελέτης. Μέθοδοι: Για τους υπολογισμούς και την εξαγωγή των κατανομών δόσεων χρησιμοποιήθηκε ο κώδικας EGSnrc …

    athens Repository record for Υπολογιστική δοσιμετρία σε απλές και ανθρωπόμορφες γεωμετρίες για τη μελέτη της επίδρασης ανομοιογενειών σε διαφορετικά κλινικά διαθέσιμα συστήματα MR-linacs (opens in a new tab)

  4. Dosimetric Effects Near Implanted Vascular Access Ports Under External Electron Beam Radiation

    … device and adjacent to the device anteriorly and laterally were taken. A clinical particle accelerator delivered typical clinical electron beams of 6, 9, 12, 16, and 20 MeV through the devices. Results showed a noticeable increase in attenuation in the presence of ports, especially for lower …

    ohiolink Repository record for Dosimetric Effects Near Implanted Vascular Access Ports Under External Electron Beam Radiation (opens in a new tab)

  5. Studium a modelování vlivu WPE (Well Proximity Effect) na integrované součástky typu MOSFET

    Hlavní náplní této práce je studium a modelování vlivu WPE (Well Proximity Effect) na integrované součástky typu MOSFET. V teoretické části jsou probrány fyzikální jevy v nanometrových technologiích, dále výrobní postupy vytváření tranzistorů typu MOSFET a možnosti modelování efektu WPE. Praktická …

    brno-tech Repository record for Studium a modelování vlivu WPE (Well Proximity Effect) na integrované součástky typu MOSFET (opens in a new tab)