Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 70 for “"leak rate"”

  1. Leak rate prediction methods for hermetically sealed devices

    … devices and MEMS devices. Knowledge of the leak rate of the packaging is also required so that the service lifetime of these devices can be predicted. Determining the leak rate of a hermetically sealed device is typically performed by measuring the leak rate of a tracer gas into said device, …

    unsw Repository record for Leak rate prediction methods for hermetically sealed devices (opens in a new tab)

  2. NSAID administration post colorectal surgery increases anastomotic leak rate - systematic review/meta-analysis

    … use is associated with an increased anastomotic leak rate. Methods A systematic review was performed for studies investigating anastomotic leak rate following NSAID use versus control after colonic or rectal anastomosis. Meta-analysis was performed to assess for overall risk of anastomotic leak …

    newfoundland Repository record for NSAID administration post colorectal surgery increases anastomotic leak rate - systematic review/meta-analysis (opens in a new tab)

  3. Using above-ground downwind methane and meteorological measurements to estimate the below-ground leak rate of a natural gas pipeline

    Natural gas (NG) leaks from below-ground pipelines present a safety, economic, and environmental hazard, and triaging the severity of leaks remains a significant issue for pipeline operators. Typically, operators conduct walking surveys using hand-held methane (CH4) detectors which output CH4 …

    colostate Repository record for Using above-ground downwind methane and meteorological measurements to estimate the below-ground leak rate of a natural gas pipeline (opens in a new tab)

  4. Factors that affect respirator fit-testing programs

    … program with specific objectives to: (1) assess leak rates in full and half mask respirators; (2) assess the effectiveness of "feedback"1 on the quality of fit; (3) evaluate the effect of daily beard growth on respirator leak rates. In the first study, it was found that the half mask respirator …

    arizona-thes Repository record for Factors that affect respirator fit-testing programs (opens in a new tab)

  5. Neon Ultra-Feinlecktest zur Vorhersage der Vakuumerhaltung resonanter Mikrosensoren

    … im Bereich 10E-16 mbar l /s. The Neon Ultra-Fine Leak test is a 100 % leak rate screen on wafer level for evacuated microresonator packages with a air leak rate resolution in the range of 10E-16 mbar l/s. The test is compatible with integrated getter and nanoliter package cavity volume.

    cau-kiel Repository record for Neon Ultra-Feinlecktest zur Vorhersage der Vakuumerhaltung resonanter Mikrosensoren (opens in a new tab)

  6. A Compressible Advection Approach in Permeation of Elastomer Space Seals

    … candidate space seal established a baseline leak rate for the computational prediction at +23°C and +50°C. A detailed uncertainty analysis was performed on the leak rate methodology, resulting in uncertainties within 7.0%. A second order, computational analysis of the developed model was …

    ohiolink Repository record for A Compressible Advection Approach in Permeation of Elastomer Space Seals (opens in a new tab)

  7. Mechanical Properties and Durability of a Composite Material at Cryogenic Temperatures

    … mechanical loading, and damage state on the leak rate of hydrogen gas through IM7/977-2 laminates were evaluated using a novel test system. Finally, the mechanical properties of several commercially available polymer films, which might prove useful as leak-resistant liners for composite …

    odu Repository record for Mechanical Properties and Durability of a Composite Material at Cryogenic Temperatures (opens in a new tab)

  8. Design and Analysis of Wafer-Level Vacuum-Encapsulated Disk Resonator Gyroscope Using a Commercial MEMS Process

    … Micro Electro Mechanical Systems (MEMS) Integrated Design for Inertial Sensors (MIDIS) process offered by Teledyne DALSA Semiconductor Incorporated (TDSI). The MIDIS process offers wafer-level vacuum encapsulation at 10 mTorr and includes Through Silicon Vias(TSVs) that allows flip chip …

    ohiolink Repository record for Design and Analysis of Wafer-Level Vacuum-Encapsulated Disk Resonator Gyroscope Using a Commercial MEMS Process (opens in a new tab)

  9. Quantitative Hermeticity Assessment of Packages with Micro to Nano-liter Cavities

    Hermeticity is a measure of the "leak-proof ness" of packages with internal cavities and is critical for ensuring proper operation of the devices/circuits enclosed in them. The most widely used hermeticity detection technique in the industry is the helium fine leak test. The exiting conduction …

    maryland Repository record for Quantitative Hermeticity Assessment of Packages with Micro to Nano-liter Cavities (opens in a new tab)

  10. Using controlled subsurface releases to investigate the effect of leak variation on above-ground natural gas detection

    Leaks from underground natural gas (NG) pipelines pose safety and environmental concerns. Pipeline leak detection generally relies on measuring surface methane (CH4) enhancements during walking surveys and/or mobile surveys that attempt to identify CH4 plumes downwind of the pipeline. The …

    colostate Repository record for Using controlled subsurface releases to investigate the effect of leak variation on above-ground natural gas detection (opens in a new tab)

  11. A NEW SMART PROCESS FOR PIPELINE INTEGRITY MONITORING

    … information to the operator of the position and rate of crude oil theft such that the situation could be appropriately arrested, thereby creating revenue security, preventing loss of containment fires, and potential deaths that could have arisen if there is explosion due to loss of containment. …

    de-montfort

  12. Design and Preliminary Measurements Inside a Simplified High Temperature Gas-Cooled Reactor Building

    … design of the facility required computing the leak rate scaled to the amount of air leaked from the prototype facility in one day. After determining the target leak rate the facility leak paths were acclimated to allow for air to leak from the facility. This was achieved by adjusting a set of …

    tamu Repository record for Design and Preliminary Measurements Inside a Simplified High Temperature Gas-Cooled Reactor Building (opens in a new tab)

  13. Material Handling for Continuous Lyophilization Process

    … doors. The wedge door has a length normalized leak rate of [︀formula]︀, and lifetime of 41,992 cycles before service is required which is 9.2 months of operation of the lyophilization machine. In order to seal the complex geometry of the interface between the linear motion system and the …

    mit Repository record for Material Handling for Continuous Lyophilization Process (opens in a new tab)

  14. Variability in Practice and Outcomes of Laparoscopic Cholecystectomy and Bile Duct Exploration (LCBDE) for Treatment of BDS – a Survey and Multi-Centre Audits of Practice in the UK

    … was attempted in 71.5% with a 77.6% success rate. The trans-choledochal approach (TD-LBDE) was attempted in 41% of cases, with a failure rate of 6.6%. Bile leak rate was significantly higher in TD-LBDE (8.8%) versus TC-LBDE (1.4%) (OR=6.76; 95% confidence intervals:3.75- 12.19; P<0.001). The …

    plymouth Repository record for Variability in Practice and Outcomes of Laparoscopic Cholecystectomy and Bile Duct Exploration (LCBDE) for Treatment of BDS – a Survey and Multi-Centre Audits of Practice in the UK (opens in a new tab)

  15. Towards new hermeticity test methods for MEMS

    … performance, it is important to know the leak rate of the package for lifetime prediction purposes. In this field, limitations in the traditional leak detection methods and standards used originally for integrated circuits and semiconductors have been blindly and often incorrectly applied …

    heriot-watt Repository record for Towards new hermeticity test methods for MEMS (opens in a new tab)

  16. The Effect of Catalyst Layer Cracks on the Mechanical Fatigue of Membrane Electrode Assemblies

    … the membrane within these mud cracks, leading to leaking during mechanical fatigue testing and the failure of the membrane. In addition, this testing of MEAs has further established that the cyclic pressurization pattern, which affects the viscoelastic behavior of the membranes, has a significant …

    vt Repository record for The Effect of Catalyst Layer Cracks on the Mechanical Fatigue of Membrane Electrode Assemblies (opens in a new tab)

  17. Characterization of Ceramic/Glass Composite Seals for Solid Oxide Fuel Cells

    … are formed. Increased heating and cooling rates during the heat treatment resulted in more and larger voids. The first goal of the current research is to suggest an appropriate heating and cooling rate to minimize the formation of microstructural defects. After identifying an appropriate …

    ohiolink Repository record for Characterization of Ceramic/Glass Composite Seals for Solid Oxide Fuel Cells (opens in a new tab)

  18. Qualification of Metallized Optical Fiber Connections for Chip-Level MEMS Packaging

    … ion etching (DRIE) of silicon on insulator substrates (SOI). The micro-machined structures, which include environmental sensors, actuators, and optical components, are susceptible to stiction related failures. A robust package is essential to transform the fragile MEMS S&A device into a rugged …

    maryland Repository record for Qualification of Metallized Optical Fiber Connections for Chip-Level MEMS Packaging (opens in a new tab)

  19. Quantifying greenhouse gas methane emissions from simulated plumes: A hybrid computational fluid dynamics (CFD) and image-based approach

    … warming potential than carbon dioxide, its accurate quantification is critical for early detection and mitigation. This thesis presents a simulation-driven framework for quantifying greenhouse gas methane leak rates using image-based projections derived from computational fluid dynamics (CFD). …

    uvic Repository record for Quantifying greenhouse gas methane emissions from simulated plumes: A hybrid computational fluid dynamics (CFD) and image-based approach (opens in a new tab)

  20. Investigation of Low-Stress Silicon Nitride as a Replacement Material for Beryllium X-Ray Windows

    … structure are burst tested, cycling tested and leak rate tested. The average burst pressure for the 100 and 200 nm films on a silicon support structure are 1.4 atm and 2.2 atm respectively. Both 100 nm and 200 nm windows are able to withstand a difference in pressure of 1 atm for over 100 cycles …

    byu Repository record for Investigation of Low-Stress Silicon Nitride as a Replacement Material for Beryllium X-Ray Windows (opens in a new tab)

Page 1 of 4