Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 18 of 18 for “"lens diameter"”
-
The Central and Peripheral Physiological Response of the Cornea to Three Hydrogel Contact Lens Diameters
… response of the cornea to three hydrogel contact lens diameters.</p><p>Methods: Fifteen subjects were fitted with three diameters (13.0, 14.0, and 15.0 mm) of Alden Classic hydrogel contact lenses (38% water content, dK 9.0). Lenses had a back vertex power of -3.00 D, center thickness of 0.1 mm, …
-
Stable Isotope Analysis on Yellowfin and Blackfin Tuna Eye Lenses Reveals Life History Patterns in the Gulf of Mexico
… inert, chronologically-layered fish-eye lenses to explore lifetime movement and trophic patterns of yellowfin tuna (Thunnus albacares) and blackfin tuna (Thunnus atlanticus) in the Gulf of Mexico (GoM). In both species, the δ13C values had a weak relationship with eye-lens diameter, …
-
Variable focal length liquid crystal immersed microlenses
… research to produce variable focal length microlenses by immersing refractive photoresist microlenses in a layer of nematic liquid crystal. The nematic liquid crystal has an electrically controllable refractive index in one polarisation, and therefore, the focal length of the lensing interface …
-
Design, fabrication, and testing of a variable focusing micromirror array lens
A reflective type Fresnel lens using an array of micromirrors is designed and fabricated using the MUMPs?? surface micromachining process. The focal length of the lens can be rapidly changed by controlling both the rotation and translation of electrostatically actuated micromirrors. The suspension …
-
Refractive effects in phase objects and associated phenomena.
… investigations deal with two novel gas lenses: the Pulsed Gas Lens and the Colliding Shock Lens. A radially expanding cylinder of gas produces a suitable density structure to focus laser light. A design of a gas lens, the Pulsed Gas Lens, using this principle is proposed as a final …
-
Ocular changes and other factors relating to two forms of contact lenses:a comparative study
The work utilising a new material for contact lenses has fallen into three parts: Physioloeical considerations: Since the cornea is devoid of blood vessels, its oxygen is derived from the atmosphere. Early hydrophilic gel contact lenses interrupted the flow of oxygen and corneal insult resulted. …
-
Optomechanical design of a two-photon imaging probe
… of design parameters, namely tissue depth, lens diameter, working distance, collection fiber angles, and the number of fibers, on the total collection efficiency. Second, we simulated Lissajous and spiral scanning strategies for piezoceramic tubes to obtain the best imaging modality. We …
-
Impact of Water Level Fluctuations on Fish Populations in Eastern South Dakota Rivers
… Cycleptus elongatus through retrospective eye lens stable isotope analysis, 2) determine the effects of record flooding in the James River on complex woody habitat and Flathead Catfish Pylodictis olivaris population structure, and 3) assess the influence of river discharge and temperature on …
-
Dynamic Wavefront Manipulation using Reconfigurable Resonant Semiconductor Metasurfaces: from Design Concepts to Functional Devices
… displays, wavefront shaping elements (e.g. lenses and waveplates) that are compact and tunable have become increasingly important. Recently, optical metasurfaces composed of judiciously-engineered nanostructures have provided an ultrathin and lightweight platform for modulating …
-
Nanopantography With Removable Membrane-Based Electrostatic Lens Arrays
… towards an array of micron-scale electrostatic lenses in direct contact with a substrate. By applying an appropriate DC voltage to the lens array with respect to the substrate, the ion beamlet entering each lens converges to a fine spot that can be 100 times smaller than the diameter of each …
-
Cost Efficient Algorithms and Methods for Spectral Efficiency in Future Radio Access
… communication systems consisting of a new lens antenna subarray (LAS) based hybrid multiple-input-multiple-output (MIMO) architecture is investigated. LAS architecture simplifies hardware requirements and lowers the cost by reducing the number of phase shifters while potentially maintaining …
-
Stable isotope analysis of fish eye lenses: reconstruction of ontogenetic trends in spatial and trophic ecology of elasmobranchs and deep-water teleosts
… rare or absent in many fishes. <br/>The fish eye lens is a unique tissue, formed via the sequential deposition of protein-filled fiber cells, which undergo no subsequent remodelling once formed. Despite having great potential to record chemical variations reflecting foraging behaviour, lenses have …
-
Design and Characterization of a Transceiver Telescope for Quantum Communications with Satellites
… encoded photons. Commercial telescopes and lenses are either not designed or optimized for the specific wavelengths required for a free space quantum link, or are not available in the required size to minimize link loss for beam transmission to a satellite in Low-Earth-orbit (LEO). Thus, a …
-
Antenna Gain Enhancement and Beamshaping using a Diffractive Optical Element (DOE) Lens
Dielectric and metamaterial lenses have been designed for gain enhancement and beam shaping. The motivation for this work came from a commercially available slotted waveguide antenna with a dielectric lens that shapes the beam and enhances the gain only in the azimuth plane. When two of these …
-
Calibration and Validation of an in Vitro Ultrasound Device to Deliver Targeted Thermal Enhancement of hMSC Osteogenesis
… the wave in a shape similar to cylinder with a diameter equivalent to the lens diameter of the transducer. The resultant power load on the transducer can be increased which in turn deposits energy onto the target that is used to increase the temperature in the well by 2°C from standard culture …
-
Isotope-Based Methods for Evaluating Fish Trophic Geographies
… I used the δ13C and δ15N values in the fish eye-lenses. I used the isotopic values in the eye-lens core (inner-most lamina) to estimate geographic location and habitat use of postlarvae from four species common to the northern West Florida Shelf (WFS). I found that isotopic values differed among …
-
Application of Anterior Segment OCT in Contact Lens Fittings
Purpose:1) To illustrate soft contact lens-induced optical distortion (apparent indentation)in optical coherence tomography (OCT) imaging and compare methods of correction utilizing contact lens thickness measurements. A previously published method (subtracting the amount the contact lenses …
-
Empirical and Modeled δ13C and δ15N Isoscapes in the Gulf of Mexico and their Application to Fish Eye Lens Migration Studies
… of the isoscapes using Red Snapper eye lens stable isotopes to infer movement histories of individual fish. Care was taken that the methods and products presented here could be used in future studies, and important considerations and caveats for these methods and products are listed at …