Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 8 of 8 for “"lifetime detection"”

  1. Studies of measurement techniques for indirect chemical sensing based on fluorescence spectroscopy and applications for fibre-optic sensors

    … using blue LED excitation.<br/>The Rapid Lifetime Detection (RLD) scheme, a fluorescence interrogation method based on direct interrogation of the decay curve following pulsed excitation was generalised, and a novel method for optimising measurement precision derived. The effect of …

    soton Repository record for Studies of measurement techniques for indirect chemical sensing based on fluorescence spectroscopy and applications for fibre-optic sensors (opens in a new tab)

  2. CMOS Single Photon Avalanche Photodiodes and Digital Control Interface for Lab-on-Chip DNA Analysis Systems

    … Avalanche Photodiodes (SPAPDs) for optical detection of fluorescently labeled molecules, such as DNA, suitable for integration in a CMOS - BioMEMS Lab on Chip. The advantages of SPAPDs versus conventional photodiode detectors are higher speed, greater sensitivity, and direct digital output. …

    alberta Repository record for CMOS Single Photon Avalanche Photodiodes and Digital Control Interface for Lab-on-Chip DNA Analysis Systems (opens in a new tab)

  3. Multifocal Multiphoton Microscopy with Adaptive Optical Correction

    … other imaging techniques such as fluorescence lifetime<br/>imaging microscopy (FLIM), adding functional information. FLIM read-­‐out<br/>is relatively straightforward using time-­‐correlated single photon counting<br/>(TCSPC). Fluorescence lifetime detection enhances the power of …

    kings Repository record for Multifocal Multiphoton Microscopy with Adaptive Optical Correction (opens in a new tab)

  4. Application of polymeric microfluidic devices for separation of single-stranded DNA

    … – was investigated for use with our fluorescence lifetime detection instrument. The accuracy and precision of the fluorescence lifetime values of dye-labeled primers used for construction of single-stranded DNA (ssDNA) sequencing tracts was determined to discern the influence of PMMA as a …

    lsu-thes Repository record for Application of polymeric microfluidic devices for separation of single-stranded DNA (opens in a new tab)

  5. Characterization of optical fibre sensor systems for applications at high temperatures

    … the fibre thermometer based on the fluorescence lifetime detection scheme of some specific fluorescent materials and fibre optic sensors based on the wavelength interrogation scheme of some specific fibre Bragg gratings. As well known, these two types of fibre optic sensors are normally most …

    city-london Repository record for Characterization of optical fibre sensor systems for applications at high temperatures (opens in a new tab)

  6. Nondestructive Evaluation Of Thermal Barrier Coatings With Thermal Wave Imaging And Photostimulated Luminescence Spectroscopy

    … oxidation for subcritical-subsurface damage detection. Thermal cycling was carried out in air with 30-minute heat-up, 10-hour dwell at 1150°C, 30-minute air-quench and 1-hour hold at room temperature. During thermal cycling, TBC specimens were evaluated non-destructively by TWI at room …

    ucf Repository record for Nondestructive Evaluation Of Thermal Barrier Coatings With Thermal Wave Imaging And Photostimulated Luminescence Spectroscopy (opens in a new tab)

  7. Schadensanalyse von hochfesten, laufenden Faserseilen

    Stahldrahtseile haben sich aufgrund ihrer hohen Bruchkraft und Betriebssicherheit sowie langjähriger Erfahrungen als Übertragungs-, Verbindungs- und Sicherheitselemente in intermittierenden Förderern, wie Kranen und Aufzügen etabliert. Sie weisen jedoch Nachteile, wie hohe Eigenmasse, geringe …

    qucosa-diss Repository record for Schadensanalyse von hochfesten, laufenden Faserseilen (opens in a new tab)