Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"light guide"”.
-
Light-Guide Snapshot Imaging Spectrometer for Biomedical Applications
Fiber-based snapshot imaging spectrometer has found increasing potential of applications in the field of biomedical imaging these years. However, currently the technique’s spatial and spectral sampling still need improvement for most requirements in biomedical applications. In this thesis, I …
-
Light-guide snapshot imaging spectrometer for remote sensing and environmental imaging applications
… the system design, the fabrication of a compact light-guiding fiber bundle by both semi-manual assembling and fully automatic 3D printing, the development of a rapid calibration method, and the system performance assessment for environmental applications. As a result, a fiber-based snapshot …
-
Development of a reinforcing fibre light-guide for use as a damage sensor within composite structures
… by using glass reinforcing fibres to produce a light-guide, which was embedded within a composite laminate. The laminate was then subjected to impact events or bending stresses of sufficient magnitude to cause damage. The impact energies used in this study varied between 2 and 10 Joules, and the …
-
Controlled extraction from light guides by means of ELE ctrophoretic modulation of total internal reflection
A prototype of a prism light guide using a new variable extraction technique is discussed. Prism light guides are hollow structures that pipe light by means of total internal reflection (TIR). High efficiency and uniform illumination can be achieved using a uniform extraction technique along the …
-
Finite difference time domain modeling of diffraction losses in dielectric structures having translational symmetry
… thesis concerns the quantification of the prism light guide's fundamental diffraction limit, by means of numerical simulation. A new technique is developed to model the intrinsically 3D problem of an off-axis incident plane striking the prism light guide wall, in a reduced 2D treatment which …
-
Transport and distribution of light energy for illuminating engineering applications
This thesis concerns the transport of light along a class of cylindrical hollow optical structures, with an aim to develop practical light transport and distribution systems for illuminating engineering applications. Based on intuition, it is postulated that it may be possible to guide light energy …
-
Advancing the liquid-argon active veto for the LEGEND experiment
… (LAr) instrumentation, which employs optical light-guide fibers to collect LAr scintillation light and veto background events via anti-coincidence with the high-purity germanium detector signals. This dissertation presents a dedicated study on advancing the LAr active veto in LEGEND-1000 using …
-
Development of UoYTube Detector for Ionising Radiation
… and prototypes that included different types of light guides (Acrylic and 3D Printed). These prototypes were characterised in terms of the signal-to-noise ratio, the optimum bias value, the energy resolution, the Acrylic versus 3D-Printed light guides, the number of counts and the optimum …
-
Large flux light guides employing discrete annular optics
This thesis concerns the development of two new light guides, the annular lens light guide and the annular reflector light guide, into viable light distribution systems. The systems use the theory that guiding light does not require the angular distribution of light to be maintained throughout the …
-
White Light Endoscopy for Minimal Invasive Surgery
… a solid-state LED or laser pumped phosphor white light system. The overall aim was to replace current xenon lamps, which have many unwanted characteristics with lower cost, higher efficiency and more environmentally friendly solid state devices to improve the benefits of endoscopic minimal …
-
Scintillation detector development for the solenoidal tracker at RHIC (STAR) and the CEBAF large acceptance spectrometer (CLAS)
… x 20 cm x 100 cm scintillators were studied with light guides of various geometries and materials attached to one end in order to optimize the uniformity and overall gain. The best results were obtained using a 61$\sp\circ$ OP-1 light guide attached to a BC 408 scintillator. An alternate approach …
-
UCN Detector development for the TRIUMF Neutron EDM experiment
… measurements were carried out to optimize the light guide design for the new UCN detector. Acrylic and air-core light guides, the latter with two different reflecting surfaces, were considered. Three prototype light guides were constructed and tested, and results were compared with simulations. …
-
Diffusion in rare-gas liquids : an experimental study
… consisting of a cesium iodide crystal, a lucite light guide and a photomultiplier tube is used for this purpose. A temperature control method is incorporated which is capable of maintaining a set temperature to within ± 0.03 K in space and time. Modified equations for the diaphragm cell are …
-
In vivo near-infrared fluorescence imaging of skin and cutaneous melanin
… of pigmented skin abnormalities and diseases. Light coming from a 785 nm diode laser is coupled into a ring light guide to uniformly illuminate the skin surface with a field-of-view (FOV) of 25 mm diameter The diffuse reflectance and emitted fluorescence photons are collected by an …
-
DESIGN AND CONSTRUCTION OF A MODULAR GAMMA CAMERA (NUCLEAR)
… geometry includes a large scintillation crystal, light guide, photomultiplier array, and analog processing electronics. Even the most modern gamma cameras built today still use the standard Anger design. The work presented here describes an alternative to the standard gamma-camera design that is …
-
Simulations and silicon wafer compatibility of a voltage-controlled optical switch using ITO/NbOx
… and the ITO/NbOx as the other plate with the light running through ITO/NbOx plate. Each of the plates are separated from one another and surrounded by a dielectric material. Simulations show that silicon dioxide (SiO2) can be used effectively to turn the ITO/NbOx into a light guide with a …
-
Fluorophore studies & instrumentation development for tumour margin estimation
… cell lines.;Additionally, a low-cost liquid light guide-based fluorescence lifetime system incorporating a translational stage has been designed for phantom margin assessments, where the margins were created using silica sol-gels. Measurements of phantom margins with Rhodamine 6G and NADH in …
-
Design study of an organ-dedicated positron emission tomography system
… (SiPM), and the SiPM channel size is 3×3 mm2. A light guide is inserted between the LYSO and the SiPM for crystal identification, and the optimal light guide thickness is evaluated as 1.2 mm. The detector is cooled by a Peltier element, and the detector performance is characterized at 10 depths. …
-
Behavior of Light in a Photobioreactor and Design of Light Guides
… in a photobioreactor system; demonstrate the light activity in a flat-plate photobioreactor; and design the light channeling system. Generally, microalgae are cultivated in open ponds and in closed photobioreactor systems. In open ponds, the productivity of microalgal biomass is very low, due …
-
Pneumatic switching of the optical power of a Fresnel lens for control of solar illumination
… for use in conjunction with collimated daylighting collection systems that collect sunlight on the façade of a multi-storey building and distribute it throughout the core areas of the building. Daylight collection systems are currently of interest since they have the potential to …
Page 1 of 3