Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 95 for “"line scan"”.

  1. Line scan camera calibration for fabric imaging

    … for 2-D image correction, but the study for 1-D line scan camera image correction is rarely done, although line scan cameras are gaining more and wider applications due to the high resolution and efficiency on 1-D data processing. A novel line scan camera correction method is proposed in this …

    texas Repository record for Line scan camera calibration for fabric imaging (opens in a new tab)

  2. Prediction of modulation detectability thresholds for line-scan displays

    … to use of most measures of image quality for line-scan imaging systems. To develop predictive models for these thresholds, an experiment was conducted to determine the modulation detectability threshold functions for a range of system parameters typical of medium- to high-resolution …

    vt Repository record for Prediction of modulation detectability thresholds for line-scan displays (opens in a new tab)

  3. LINE SCAN FOCAL MODULATION MICROSCOPY FOR RAPID IMAGING OF THICK BIOLOGICAL SAMPLES

    LINE-SCAN FOCAL MODULATION MICROSCOPY IS A HIGH-SPEED, HIGH-RESOLUTION IMAGING TECHNIQUE CAPABLE OF DEEP IMAGING OF THICK BIOLOGICAL TISSUES. THIS THESIS DESCRIBES THREE DIFFERENT IMPLEMENTATIONS OF THE LINE-SCANNING FOCAL MODULATION MICROSCOPE. THE PERFORMANCE OF THE MICROSCOPE IS VALIDATED BY …

    nus Repository record for LINE SCAN FOCAL MODULATION MICROSCOPY FOR RAPID IMAGING OF THICK BIOLOGICAL SAMPLES (opens in a new tab) Download file for LINE SCAN FOCAL MODULATION MICROSCOPY FOR RAPID IMAGING OF THICK BIOLOGICAL SAMPLES (opens in a new tab)

  4. Implementation of a Line-Scan Camera Triangulation Sensor for a Ball Balancer

    … the position and velocity of the ball. Using two line-scan cameras, the ball is located by triangulation without direct contact.

    calpoly Repository record for Implementation of a Line-Scan Camera Triangulation Sensor for a Ball Balancer (opens in a new tab)

  5. Line scan photoluminescence and electroluminescence imaging of silicon solar cells and modules

    … source of electricity. In this thesis the use of line scan photoluminescence and electroluminescence imaging is demonstrated for this purpose. A novel laboratory line scan luminescence imaging tool was designed and built to enable the acquisition of line scan photoluminescence and …

    unsw Repository record for Line scan photoluminescence and electroluminescence imaging of silicon solar cells and modules (opens in a new tab)

  6. OPTIMIZATION OF LINE-SCAN FOCAL MODULATION MICROSCOPE FOR THICK TISSUE IN-VIVO IMAGING

    This thesis presents the optimization of the line scan focal modulation microscopy(LSFMM) system in terms of theoretical studies, system optimization, and combination with other novel imaging techniques. Firstly, an in-depth point spread function (PSF) mathematical model was built up to evaluate …

    nus Repository record for OPTIMIZATION OF LINE-SCAN FOCAL MODULATION MICROSCOPE FOR THICK TISSUE IN-VIVO IMAGING (opens in a new tab) Download file for OPTIMIZATION OF LINE-SCAN FOCAL MODULATION MICROSCOPE FOR THICK TISSUE IN-VIVO IMAGING (opens in a new tab)

  7. Line-Scan Spectral-Domain Optical Coherence Tomography for Cellular Resolution Structural and Vascular Imaging of Biological Tissues

    … these challenges by developing: (i) a broadband line-scan (LS) spectral-domain (SD) OCT system that combines micrometer-scale spatial resolution and ultrafast image acquisition rate; (ii) an image reconstruction method for restoring the diffraction-limited lateral resolution of the LS SD-OCT …

    waterloo Repository record for Line-Scan Spectral-Domain Optical Coherence Tomography for Cellular Resolution Structural and Vascular Imaging of Biological Tissues (opens in a new tab)

  8. Powell Lens-based Line-Scan Spectral Domain Optical Coherence Tomography for Cellular Resolution Imaging of Biological Tissues

    A line-scan spectral-domain optical coherence tomography system was developed for corneal imaging. It utilizes a Powell lens to achieve a better line illumination power distribution than the conventional use of cylindrical lenses. It achieves a lateral resolution of <2.1 microns and ~4.1 microns in …

    waterloo Repository record for Powell Lens-based Line-Scan Spectral Domain Optical Coherence Tomography for Cellular Resolution Imaging of Biological Tissues (opens in a new tab)

  9. Generative models for unsupervised anomaly detection in temporal data

    Line-scan imagery has become a core sensing modality in automated railway inspection, enabling high-resolution, continuous monitoring of track structures. Unlike conventional 2D images, line-scan images are constructed row-by-row as the camera moves along the track, forming temporally ordered …

    whiterose Download PDF for Generative models for unsupervised anomaly detection in temporal data (opens in a new tab)

  10. FAST RAMAN SPECTROSCOPY AND STIMULATED RAMAN SCATTERING MICROSCOPY FOR LABEL-FREE BIOMOLECULAR IMAGING

    … speed. We first report the development of a line-scan Raman technique for rapid Raman imaging, which can acquire Raman image of 200 × 200 pixels within 3.3 minutes. We also develop a line-scan stimulated Raman scattering (SRS) imaging technique for video-rate biochemical imaging with 5 times …

    nus Repository record for FAST RAMAN SPECTROSCOPY AND STIMULATED RAMAN SCATTERING MICROSCOPY FOR LABEL-FREE BIOMOLECULAR IMAGING (opens in a new tab) Download file for FAST RAMAN SPECTROSCOPY AND STIMULATED RAMAN SCATTERING MICROSCOPY FOR LABEL-FREE BIOMOLECULAR IMAGING (opens in a new tab)

  11. Complementary imaging for pavement cracking measurements

    … aimed to develop a new imaging system that can scan pavement surface at highway speed and determine the severity level of pavement cracking without using any artificial lighting. The new system consists of dual line-scan cameras that are installed side by side to scan the same pavement area as …

    texas Repository record for Complementary imaging for pavement cracking measurements (opens in a new tab)

  12. Fluorescence Microscopy with Tailored Illumination Light

    … I have designed and prototyped: 1) a highly inclined swept illumination for wide-field fluorescence microscope, which greatly improves the sectioning capability with a large field of view and ultrasensitivity; 2) dual inclined line-scan confocal microscope, which reduces photodamage while …

    ucf Repository record for Fluorescence Microscopy with Tailored Illumination Light (opens in a new tab)

  13. Advances in Raman and Surface-Enhanced Raman Spectroscopy: Instrumentation, Plasmonic Engineering and Biomolecular Sensing

    … instrumentation, we have built a high-throughput line-scan Raman microscope system and a novel parallel Raman microscope based on multiple-point active-illumination and wide-field hyperspectral data collection. Using the line-scan Raman microscope, we have performed chemical imaging of intact …

    houston Repository record for Advances in Raman and Surface-Enhanced Raman Spectroscopy: Instrumentation, Plasmonic Engineering and Biomolecular Sensing (opens in a new tab)

  14. Techniques for single-shot volumetric fluorescence imaging

    … In the first part, we describe a multiplane line-scan imaging strategy, which uses a series of axially distributed reflecting slits to probe different depths within a sample volume. Our technique, called line-scan multi-z confocal microscopy, enables the simultaneous imaging of an optically …

    bu Repository record for Techniques for single-shot volumetric fluorescence imaging (opens in a new tab)

  15. Techniques for capture and analysis of hyperspectral data

    … a novel technique which utilises a rotational line-scan rather than a linear line-scan. Furthermore, a method for automatically calibrating this system using a calibration object is described. Compared with traditional linear scanning systems, the performance is shown to be high enough that a …

    strathclyde Repository record for Techniques for capture and analysis of hyperspectral data (opens in a new tab)

  16. Evaluation of Digital Imaging Systems Used in Highway Applications

    … cameras; forward-view and side-view digital area-scan cameras for capturing images of traffic signs and right-of-way safety features, and a pavement digital line-scan or area-scan camera for capturing images of the pavement surface. In addition to the 3-laser and accelerometer-based profiling …

    usf Repository record for Evaluation of Digital Imaging Systems Used in Highway Applications (opens in a new tab)

  17. Line-Field Spectral Domain Optical Coherence Tomography: Design and Biomedical Applications

    … motion and suppress motion-induced artifacts. Line-scan OCT (LS-OCT) utilizes a 2D lens, such as a cylindrical lens, as the line generator to project a line-shaped detection beam onto the sample instead of the focused pencil beam traditionally used in OCT systems. Combined with high-speed 2D …

    waterloo Repository record for Line-Field Spectral Domain Optical Coherence Tomography: Design and Biomedical Applications (opens in a new tab)

  18. The effect of nonlinearity in robotic vision systems

    … thesis, an application of generic approach to nonlinear image processing is described which is implemented in real-life application. Consideration is given to the general geometrical resampling process in which output pixels are estimated by interpolation of input pixels. However, here the …

    ttu Repository record for The effect of nonlinearity in robotic vision systems (opens in a new tab)

  19. Modulation of spontaneous Ca2+ release from the sarcoplasmic reticulum by FKBP12.6 in rabbit ventricular cardiomyocytes

    … velocity of waves were measured using line-scan confocal imaging of beta-escin permeabilised cardiomyocytes perfused with 10muM Fluo-3 or Fluo-5F. Spontaneous Ca2+ waves were evident at cellular [Ca2+] >200nM. Peak [Ca2+] during a wave was 2-2.2)iM: minimum [Ca2+] between waves was …

    glasgow Download PDF for Modulation of spontaneous Ca2+ release from the sarcoplasmic reticulum by FKBP12.6 in rabbit ventricular cardiomyocytes (opens in a new tab)

Page 1 of 5