Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"linear imaging"”.

  1. Advances in non linear imaging microscopy for tissue and in-vivo biological samples characterization

    … field of enormous research interest. Non-linear imaging microscopy is a reliable diagnostic tool for microscopic studies, as it is a minimally invasive technique with high resolution, while also providing the ability to simultaneously capture images through different non-linear signals …

    greece Repository record for Advances in non linear imaging microscopy for tissue and in-vivo biological samples characterization (opens in a new tab)

  2. Characterization of algorithms and performance of a fine-resolution active interrogation system

    … in cargo inspection as well as in medical imaging, among other applications. In this work, a novel linear imaging array is characterized, and reconstruction algorithm developed, for active interrogation. The system consists of lutetium-yttrium oxyorthosilicate (LYSO) scintillator crystals …

    gatech Repository record for Characterization of algorithms and performance of a fine-resolution active interrogation system (opens in a new tab)

  3. Macrophage imaging in solid tumors using non-linear ultrasound

    … of immune‐cell biology. Despite advances in imaging technologies to monitor macrophages, the lack of real-time imaging methods with high sensitivity and resolution in deep tissue to characterize the motion dynamics and macrophage interaction with the TME in vivo remains a challenge. In this …

    gatech Repository record for Macrophage imaging in solid tumors using non-linear ultrasound (opens in a new tab)

  4. A characterisation of fibrolastic foci and their production of fibrillar collagens in idiopathic pulmonary fibrosis

    … biomechanical, histological, and non-linear imaging analyses. A long term model of fibrillar collagen production by fibroblastic foci was established using parenchymal lung fibroblasts explanted from IPF or non-fibrotic lung tissue.<br/><br/>This study demonstrates that the application …

    soton Download PDF for A characterisation of fibrolastic foci and their production of fibrillar collagens in idiopathic pulmonary fibrosis (opens in a new tab)

  5. Super-resolution microscopy with spatial modes of light

    <p>The resolution of imaging devices is ultimately limited by the diffraction of light. This limit can be circumvented by exploiting near-field phenomena, non-linearities of the sample or specific illumination schemes, which led to the recent explosion of optical super-resolution techniques. …

    oxford Repository record for Super-resolution microscopy with spatial modes of light (opens in a new tab)

  6. Coherent Anti-Stokes Raman Scattering Microscopy for Biomedical Applications

    … as a powerful tool for non-invasive chemical imaging of biological samples. CARS microscopy provides an endogenous contrast mechanism that it is sensitive to molecular vibrations. CARS microscopy is recognized as a great imaging system, especially in vivo experiments since it eliminates the …

    ottawa-retro Repository record for Coherent Anti-Stokes Raman Scattering Microscopy for Biomedical Applications (opens in a new tab)

  7. Non-scanning imaging spectrometry.

    The objective of imaging spectrometry is to collect three-dimensional data about object space. Two of the three dimensions are spatial. The third dimension is spectral. Current techniques rely on some form of scanning, causing instruments to include moving components and/or to be capable of imaging …

    arizona-thes Repository record for Non-scanning imaging spectrometry. (opens in a new tab)

  8. Optical and electronic properties of transition metal dichalcogenides on pre-patterned surfaces

    … with means of optical spectroscopy and non-linear imaging. The distinct PL emission stemming from the neutral exciton (X0) in suspended regions highlights the impact of substrate. Furthermore, we show that Polarization-Resolved Second Harmonic Generation (P-SHG) can be an all optical tool to …

    greece Repository record for Optical and electronic properties of transition metal dichalcogenides on pre-patterned surfaces (opens in a new tab)

  9. Development of Miniature Objectives for Clinical Applications

    … field (critical in clinical applications) while imaging at high resolution and (b) analyzing material properties that are critical in non-linear imaging and developing technologies specific to such materials. Two example system designs were developed to address these challenges. This dissertation …

    rice Repository record for Development of Miniature Objectives for Clinical Applications (opens in a new tab)

  10. Rapid separation of biologically important low molecular weight compounds by microchip electrophoresis and ultra-fast performance liquid chromatography

    … condition).The method was validated in terms of linearity, precision, and LOD. The optimized method was then transferred to a microchip electrophoresis system. Two different types of injection i.e. gated and pinched, were investigated. This microchip method represents the fastest reported chiral …

    cork Repository record for Rapid separation of biologically important low molecular weight compounds by microchip electrophoresis and ultra-fast performance liquid chromatography (opens in a new tab)

  11. Instigating chiral-selective nonlinear optical phenomena in metamaterials

    … from the two incident polarizations; nonlinear and linear imaging is provided. In a later set of experiments, these chiral nanoarcs are opened up to place emitters in the most light-confining and chirally sensitive regions of the meta-structure. Tested with an ultra-fast laser, the …

    gatech Repository record for Instigating chiral-selective nonlinear optical phenomena in metamaterials (opens in a new tab)

  12. Computed-tomography imaging spectropolarimeter (CTISP)

    A complete Stokes imaging spectropolarimeter has been developed based on the principles of computed-tomography, spectrometry and polarimetry. The Computed-Tomography Imaging SpectroPolarimeter (CTISP) is a polarization extension to the Computed Tomography Imaging Spectrometer (CTIS)¹. Imaging …

    arizona-thes Repository record for Computed-tomography imaging spectropolarimeter (CTISP) (opens in a new tab)

  13. Properties of the incomplete Abel transform and some of its generalizations.

    The mathematical model of a two-dimensional linear imaging system is given in terms of an integral operator whose kernel is called the point-spread function (PSF) of the system. Through this model, the PSF completely characterizes the noise-free imaging properties of the system. Therefore, in order …

    arizona-thes Repository record for Properties of the incomplete Abel transform and some of its generalizations. (opens in a new tab)

  14. Coherent Anti-Stokes Raman Scattering Miniaturized Microscope

    … fusion of light microscopy and well-studied nonlinear processes has broken through this barrier and enabled the collection of vast amounts of additional information beyond the topographical information relayed by traditional microscopes. Through nonlinear imaging modalities, chemical information …

    ottawa-retro Repository record for Coherent Anti-Stokes Raman Scattering Miniaturized Microscope (opens in a new tab)

  15. Chondrolabral Damage in the Natural Hip Joint

    … using histological examination and novel non- linear imaging methods to analyse changes to the structure in particular with collagen fibres present in the tissue to determine the effects of damage on the structure. The simulation model was developed with the potential for assessing early …

    whiterose Download PDF for Chondrolabral Damage in the Natural Hip Joint (opens in a new tab)

  16. Nelineární zobrazení v 100 keV transmisním elektronovém mikroskopu

    Bakalářská práce se zabývá popisem zobrazení v transmisním elektronovém mikroskopu. Práce je zaměřena na odvození rovnice popisující pozorovanou intenzitu a kontrast v rovině detektoru. V práci jsou porovnány teoretické lineární a nelineární rovnice zobrazení pro výsledný kontrast s reálnými daty …

    brno-tech Repository record for Nelineární zobrazení v 100 keV transmisním elektronovém mikroskopu (opens in a new tab)

  17. A study on using linear electromagnetic imaging methods for obtaining the grain/air interface inside metallic-walled grain storage bins

    … interface is a starting point for full 3-D imaging of stored grain. The methods currently used to estimate the grain/air interface are computationally expensive, and have not been designed to image non-symmetric grain surfaces. To obtain the grain/air interface we studied and applied linear …

    manitoba Repository record for A study on using linear electromagnetic imaging methods for obtaining the grain/air interface inside metallic-walled grain storage bins (opens in a new tab)

  18. PHASE-SPACE PERSPECTIVE OF PARTIALLY COHERENT IMAGING: APPLICATIONS TO BIOLOGICAL PHASE MICROSCOPY

    … rather alter the phase of incident illumination. Imaging of phase specimens requires appropriate illumination and appropriate manipulation of scattered light to produce an image with phase contrast. The specimen may be illuminated from a single direction (e.g. using a laser, as in holography) or …

    nus Repository record for PHASE-SPACE PERSPECTIVE OF PARTIALLY COHERENT IMAGING: APPLICATIONS TO BIOLOGICAL PHASE MICROSCOPY (opens in a new tab) Download file for PHASE-SPACE PERSPECTIVE OF PARTIALLY COHERENT IMAGING: APPLICATIONS TO BIOLOGICAL PHASE MICROSCOPY (opens in a new tab)

  19. Sparse sensor arrays for active sensing - Array configurations and signal processing

    … simple array of uniformly spaced sensors with a linear or rectangular geometry. However, a uniform array spanning a large electrical aperture may become prohibitively expensive, as many sensors and costly RF-IF front ends are needed. In contrast, sparse sensor arrays require drastically fewer …

    aalto Repository record for Sparse sensor arrays for active sensing - Array configurations and signal processing (opens in a new tab)

Page 1 of 2