Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 154 for “"liquid/liquid interface"”

  1. Electrokinetic Biosensing at a Liquid-Liquid Interface

    … When an electric field is applied across the interface a liquid displacement occurs across the interface. This displacement is found to be frequency dependent. At low frequency, roughly 1 MHz, the fluid with a higher conductivity displaces into that of a lower conducitivity. On the contrary, …

    jhu Repository record for Electrokinetic Biosensing at a Liquid-Liquid Interface (opens in a new tab)

  2. Chiral Interactions and Sensing at Liquid|Liquid Interface

    … to the study of chiral ion transfer at the interface between two immiscible electrolytes solutions (ITIES), as a promising method of simplifying chiral detection and separation. As a proof of concept, for the study of chiral compounds at liquid|liquid interface, three different approaches …

    durham Repository record for Chiral Interactions and Sensing at Liquid|Liquid Interface (opens in a new tab)

  3. HIGH SPEED CONTINUOUS ADDITIVE MANUFACTURING AT THE LIQUID-LIQUID INTERFACE

    This work investigates stereolithography at a liquid-liquid interface. The first working curves printed at a liquid-liquid interface are presented and closely match those printed at liquid-solid interfaces. A model describing the curing behavior at a liquid-liquid interface is derived and suggests …

    cornell Repository record for HIGH SPEED CONTINUOUS ADDITIVE MANUFACTURING AT THE LIQUID-LIQUID INTERFACE (opens in a new tab)

  4. Bimolecular charge transfer reactions at and through the liquid-liquid interface

    Interfaces are ubiquitous in Nature. Among them, soft interfaces are essential constituents of biological tissues. Indeed, many electrochemical reactions and phenomena take place at these interfaces. In this respect, ITIES are an interesting model to study such phenomena because they are notably …

    epfl Repository record for Bimolecular charge transfer reactions at and through the liquid-liquid interface (opens in a new tab)

  5. A surfactantless emulsion as a model for the liquid-liquid interface.

    An electrochemically polarised liquid-liquid interface in the form of a surfactantless oil-in-water emulsion has been developed, and its creation, stabilisation and use as a model liquid-liquid system for structural characterisation using Small Angle Neutron Scattering (SANS) are described. The …

    ucl Repository record for A surfactantless emulsion as a model for the liquid-liquid interface. (opens in a new tab)

  6. Diffusion Through the Liquid-Liquid Interface: Interfacial Resistance in Three-Component Systems

    Made available in DSpace on 2014-12-08T23:18:09Z (GMT). No. of bitstreams: 1 6507180.pdf: 2904361 bytes, checksum: 226b1be5dd8333df62b53cd7dfdec165 (MD5) Previous issue date: 1965

    uiuc Repository record for Diffusion Through the Liquid-Liquid Interface: Interfacial Resistance in Three-Component Systems (opens in a new tab)

  7. Mass Transfer Across a Liquid-Liquid Interface with and Without Chemical Reaction

    … the steady state mass transfer across a liquid-liquid interface accompanied by a very slow, second order, irreversible chemical reaction using a glass vessel. Both liquid phases were well stirred and the lower phase was allowed to flow in and out of the reactor continuously. The system …

    mcmaster Repository record for Mass Transfer Across a Liquid-Liquid Interface with and Without Chemical Reaction (opens in a new tab)

  8. ELECTROCHEMISTRY AT LIQUID/LIQUID INTERFACE TO EVALUATE SOLVENT EXTRACTION TECHNIQUE IN NUCLEAR REPROCESSING

    Hydrophobic room temperature ionic liquids (RTILs) have been demonstrated as effective alternative solvents to reprocess spent nuclear waste. Our group developed a new hydrophobic RTIL at low cost which is trihexyltetradecylphosphonium tetrakis(pentafluorophenyl)borate (P66614TB). The …

    uwo Repository record for ELECTROCHEMISTRY AT LIQUID/LIQUID INTERFACE TO EVALUATE SOLVENT EXTRACTION TECHNIQUE IN NUCLEAR REPROCESSING (opens in a new tab)

  9. ELECTROCHEMISTRY AT LIQUID/LIQUID INTERFACE TO EVALUATE SOLVENT EXTRACTION TECHNIQUE IN NUCLEAR REPROCESSING

    Hydrophobic room temperature ionic liquids (RTILs) have been demonstrated as effective alternative solvents to reprocess spent nuclear waste. Our group developed a new hydrophobic RTIL at low cost which is trihexyltetradecylphosphonium tetrakis(pentafluorophenyl)borate (P666i4TB). The …

    uwo Repository record for ELECTROCHEMISTRY AT LIQUID/LIQUID INTERFACE TO EVALUATE SOLVENT EXTRACTION TECHNIQUE IN NUCLEAR REPROCESSING (opens in a new tab)

  10. Morphology and Dynamics of Catenanes in Dilute Solutions and at Liquid/Liquid Interface

    … polymers. The behavior of diblock catenane at an interface of twoimmiscible solvents provided interesting morphological and dynamical understanding. Aninteresting dynamics of the two blocks, both translational and rotational, has been observedat the liquid/liquid interface. At the interface, the …

    ohiolink Repository record for Morphology and Dynamics of Catenanes in Dilute Solutions and at Liquid/Liquid Interface (opens in a new tab)

  11. Characterization of the liquid-liquid interface and its influence on metal extraction processes.

    … forms and its Ni complex at the hexanes-aqueous interface are very nearly the same. The Ni²⁺ is complexed by HDSO and DSO⁻ in the bulk aqueous and hexanes-aqueous interface. The interfacial rate constants for HDSO and DSO⁻ are 3-5 times smaller than the bulk aqueous values. The interfacial rate …

    arizona-thes Repository record for Characterization of the liquid-liquid interface and its influence on metal extraction processes. (opens in a new tab)

  12. Characterization of surfactant adsorption at a liquid-liquid interface by drop volume tensiometry

    … the adsorption behavior of surfactants at liquid-liquid interfaces. In this work, selected surfactants are tested at the mineral oil-water interface using a drop volume tensiometer. A model is developed to account for the neck formation in suspended drops under certain experimental …

    concordia

  13. Study on the Circular Dichroism Measurements of Molecular Aggregates at Liquid-Liquid Interface

    著者による幾つか修正のもの

    osaka

Page 1 of 8