Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 160 for “"liquid cooling"”.

  1. Development of Liquid Cooling for PCs

    In recent years, existing solutions for cooling personal computer CPUs have been supplemented by a new product category, factory sealed water cooling loops. These systems, consisting of a water block with an integrated pump, a fan and a radiator, perform well compared to the air cooling solutions …

    chalmers Repository record for Development of Liquid Cooling for PCs (opens in a new tab)

  2. Electric Vehicle Battery Thermal Management Using Liquid Cooling

    … management system (BTMS). Next, brief reviews on liquid-cooled papers pulled from the R&D side are covered, organized by numerical and experimental studies, as well as the type of cooling (indirect single-phase, indirect two-phase, direct single-phase, and direct two-phase). Chapters 4-5 features …

    hawaii Repository record for Electric Vehicle Battery Thermal Management Using Liquid Cooling (opens in a new tab)

  3. Liquid cooling garment for personal protective ensemble : modeling and simulation

    … To protect the PPE wearer from heat stress, a liquid cooling garment is widely accepted to provide personal cooling inside the PPE. For an impermeable PPE or a high humid environment, sweat evaporation is also prevented, and moisture accumulation may lead to discomfort. It is important to make …

    ucf Repository record for Liquid cooling garment for personal protective ensemble : modeling and simulation (opens in a new tab)

  4. Stacked Microchannel Heat Sinks for Liquid Cooling of Microelectronics Devices

    … heat sink was developed to provide efficient cooling for microelectronics devices at a relatively low pressure drop while maintaining chip temperature uniformity. Microfabrication techniques were employed to fabricate the stacked microchannel structure, and experiments were conducted to study …

    gatech Repository record for Stacked Microchannel Heat Sinks for Liquid Cooling of Microelectronics Devices (opens in a new tab)

  5. Investigation of liquid cooling on M9506A high density Keysight AXIE chassis

    … air-cooled heat sinks are the dominant cooling method used in the electronics industry, accounting for 86% of high-density cooling in data centers. However, the continual performance increases of electronics equipment are pushing these air-cooled methods to their limit. Fundamental …

    colostate Repository record for Investigation of liquid cooling on M9506A high density Keysight AXIE chassis (opens in a new tab)

  6. Single-phase liquid cooling for thermal management of power electronic devices

    … By eliminating layers, the integration of liquid cooling techniques has shown promise to significantly reduce (up to 25% reduction) in the thermal resistance in power electronic cooling systems as compared to the thermal resistance found using a conventional cold plate cooler design. Thus, …

    gatech Repository record for Single-phase liquid cooling for thermal management of power electronic devices (opens in a new tab)

  7. Testing and evaluation of three liquid cooling garments for use during spaceflight.

    … findings between the garments. Use of a cooling hood had no discernable effect. Amount of tubing coverage was related to whole body sweat rate while flow rate affected skin temperatures and local sweat rate. Conclusion: All three garments were similar in terms of regulating core …

    umn Repository record for Testing and evaluation of three liquid cooling garments for use during spaceflight. (opens in a new tab)

  8. Modeling of a Single-Phase Liquid Cooling System for Power Electronics Applications

    … investigates the reliability of a single-phase, liquid cooling system used for the thermal management of a medium power level converter system. The system utilizes a plastic insert cold plate design to provide even cooling over the backside of a power electronics device by directing coolant …

    maryland Repository record for Modeling of a Single-Phase Liquid Cooling System for Power Electronics Applications (opens in a new tab)

  9. Performance Of The Shortened Liquid Cooling Warming Garment During Simulated Emergency EVA

    … leading to increased internal temperature. Cooling garments are utilized to maintain human thermal equilibrium. NASA’s Liquid Cooling and Ventilation Garment (LCVG) has been in use for decades. Koscheyev, Leon, and colleagues developed a physiologically designed Shortened Liquid Cooling …

    nodak Repository record for Performance Of The Shortened Liquid Cooling Warming Garment During Simulated Emergency EVA (opens in a new tab)

  10. Thermal management of three-dimensional integrated circuits using inter-layer liquid cooling

    … test-bed for evaluating a 3D inter-layer liquid cooling platform is developed. Experimental thermal testing results for an air-cooled chip and a liquid-cooled chip are compared. Microchannel heat sink cooling shows a significant junction temperature and heat sink thermal resistance …

    gatech Repository record for Thermal management of three-dimensional integrated circuits using inter-layer liquid cooling (opens in a new tab)

  11. Double-Sided Liquid Cooling for Power Semiconductor Devices Using Embedded Power Technology

    … and interconnection requirements. Advanced cooling schemes, such as double-sided, forced liquid convection or multi-phase flow, can be implemented with non-wire bond packaging to improve thermal management while maintaining proper electrical performance. Embedded power is one such packaging …

    vt Repository record for Double-Sided Liquid Cooling for Power Semiconductor Devices Using Embedded Power Technology (opens in a new tab)

  12. Heat Transfer Characteristics of Natural Convection within an Enclosure Using Liquid Cooling System.

    … safe temperature level (85℃) is determined. The cooling system is tested for varying values of applied power in the range of 15−40𝑊. The study is based on both numerical models and experimental observations. The numerical work was developed using the commercial software (ANSYS-Icepak) to simulate …

    bradford Repository record for Heat Transfer Characteristics of Natural Convection within an Enclosure Using Liquid Cooling System. (opens in a new tab)

  13. Design and Modeling of a High Reliability Pump for Liquid Cooling Data Center Servers

    … energy, of which about 40% is spent on cooling [1, 2]. Current cooling strategies fail to meet the heat transfer requirements of current microprocessors due to high heat fluxes resulting from increased component density and decreased device size. The goal of this study is focused on the …

    washington Repository record for Design and Modeling of a High Reliability Pump for Liquid Cooling Data Center Servers (opens in a new tab)

  14. Physiological Responses of Men During the Continuous Use of a Portable Liquid Cooling Vest

    … are not feasible. In these cases, personal cooling is often employed. There are three main types of personal cooling: liquid, air, and passive. Each has its own advantages and disadvantages. This study focuses on continuous cooling using a portable liquid cooling system (LCS). The LCS used a …

    usf Repository record for Physiological Responses of Men During the Continuous Use of a Portable Liquid Cooling Vest (opens in a new tab)

  15. DynaCool - Simulating Efficient Liquid Cooling for Current and Next Generation Large Scale Data Centres

    … the servers, which creates a real problem of cooling in LSDC’s. Air cooling systems in LSDC’s are struggling to handle the increased cooling demands, which is why they account for 40% of the total energy consumed. The rest of the energy consumed is used to power the IT equipment and data …

    auckland-tech Repository record for DynaCool - Simulating Efficient Liquid Cooling for Current and Next Generation Large Scale Data Centres (opens in a new tab)

  16. Liquid Cooling System for a High Power, Medium Frequency, and Medium Voltage Isolated Power Converter

    … of the components stays within a safe range, cooling systems play a significant part in the performance and reliability of power electronics systems. Air and liquid cooling are the two primary cooling technologies used in power electronics systems. To transfer heat from the devices to the …

    south-carolina Repository record for Liquid Cooling System for a High Power, Medium Frequency, and Medium Voltage Isolated Power Converter (opens in a new tab)

  17. From Melting to Vaporization: Microscale Phase-Change Strategies for Liquid Cooling of High-power Electronics

    … chip, server, and rack power continue to rise, cooling is becoming a major part of the total energy cost of computing. Heat must be removed from the chip, transported through the package and cold plate, and rejected to the environment. Each step consumes energy through pumps, fans, facility …

    maryland Repository record for From Melting to Vaporization: Microscale Phase-Change Strategies for Liquid Cooling of High-power Electronics (opens in a new tab)

Page 1 of 8