Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"liquid damper"”.
-
Tuned Liquid Damper Design Using Liquid Sloshing in a Horizontal Cylindrical Tank
… in tall buildings is known as the Tuned Mass Damper , where a mechanical mass (pendulum, bogey, cylinder) is located at the top portion of the building and is connected to the building through a suspension. This mechanical mass – suspension system is designed to oscillate out of phase with the …
-
THE EFFECT OF SCREEN GEOMETRY ON THE PERFORMANCE OF A TUNED LIQUID DAMPER
<p>In recent years, the use of tuned liquid dampers (TLD) as dynamic vibration absorbers has increased in popularity due to their low cost and ease of installation. A TLD is a partially fluid filled tank (commonly water) that has a fundamental sloshing frequency close to the natural frequency of …
-
The performance of a tuned liquid damper equipped with inclined and oscillating damping screens
… <p>The first application of the tuned liquid damper (TLD) to mitigate the</p> <p>dynamic vibrations of structures was only around 20 years ago and has just been</p> <p>recently applied in North America. TLDs are partially fluid filled tanks (usually</p> <p>water) with a fundamental …
-
Numerical Investigation of Tuned Liquid Damper Performance Attached to a Single Degree of Freedom Structure
Tuned liquid dampers (TLDs) are increasingly being used as dynamic vibration absorbers to minimize the vibration of structures. A tuned liquid damper is a tank filled with a liquid. When attached to a structure, the liquid sloshing action inside the TLD dampens and absorbs part of the energy given …
-
PERFORMANCE OF DYNAMIC VIBRATION ABSORBERS ON BUILDINGS WITH COUPLED MODES
<p>Dynamic absorbers, including the tuned mass damper (TMD) and the tuned liquid damper (TLD) , have been widely used in buildings to attenuate dynamic response. As the complexity of buildings increases, their response may become susceptible to torsional motion. The induced torsional motion can be …
-
Efficient Smoothed Particle Hydrodynamics Modelling of Tuned Liquid Dampers
The tuned liquid damper (TLD) is used to reduce the motion of many tall structures around the world. A TLD consists of a partially filled tank of liquid located near the location of maximum structural response. Due to the nonlinear behavior of sloshing liquids, a suitable nonlinear model must be …
-
Seismic performance of mass-variable tuned liquid dampers with particles fluidization in building applications
"A conventional tuned liquid damper (TLD) generates a relatively small control force associated with low density of sloshing water. To overcome this main drawback, proposed in this study is a new TLD system composed of water and fine particles in a rectangular tank of sloping bottom. When subjected …
-
The Effect Of Wave Breaking On The Performance Of Tuned Liquid Dampers
… of the wave breaking on the performance of Tuned Liquid Damper (TLD). In this model, the Volume Of Fluid VOF method was used to construct the free surface and the surface tension was taken into consideration to evaluate the wave breaking. The model was implemented on incompressible, 2D flow water …
-
Numerical Investigation of Sloshing Motion Inside Tuned Liquid Dampers With And Without Submerged Screens
… been developed to solve the sloshing motion of liquid in a Tuned Liquid Damper (TLD) outfitted by slat screens under large and random amplitude of excitation. It is based on the finite-difference method. The free surface has been reconstructed using volume of fluid method. Donor-acceptor …
-
A Numerical Study of The Performance of Tuned Liquid Dampers
… Helvetica}</p> <p>Using an integrated Tuned Liquid Damper (TLD)-Structure in-house developed numerical algorithm that has been validated against recent rigorous experimental tests, the TLD performance was analyzed when coupled with a vibrating Single Degree of Freedom (SDOF) body representing …
-
Sukamosios svarstyklės mikroniutonmetrų eilės sukimo momento matavimui /
… quicker its beneficial to use oscillation damper. A liquid damper with a rotating hexagon submerged in liquid is a simple and effective solution. It was empirically found that the best liquid for the damper is starch paste (1 l of water to 6 g of starch). This torsion balance was used to …
-
Návrh a realizace demonstrátoru dynamického tlumiče vibrací využívajícího kapalinu
Kapalinové dynamické tlumiče jsou jedním ze způsobů, jak snížit dynamickou odezvu systému na vnější podněty. V rámci práce jsou představeny typy a princip dynamických tlumičů vibrací, zejména těch kapalinových. Dále je navržen demonstrátor sloupcového kapalinového tlumiče s ovlivnitelnou velikostí …
-
Otimização de múltiplos amortecedores líquidos sintonizados para pórticos de aço com irregularidades verticais usando o CIOA
Estruturas com irregularidades geométricas, especialmente do tipo setback, apresentam elevada vulnerabilidade frente a excitações sísmicas,devido à descontinuidade de rigidez e massa ao longo da altura e à consequente concentração de deformações e esforços, o que compromete sua capacidade de …