Results 1 to 7 of 7 for “"liquid distributor"”
-
Impact of Bubble Characteristics and Particle Properties on the Fluid Dynamics of an Ebullated Bed Hydroprocessor
… freeboard were simulated in a high pressure gas-liquid bubble column operating at 6.5 MPa using nitrogen and a 0.5 wt.% aqueous ethanol solution. Local bubble characteristics, including gas holdups, bubble rise velocities, and chord lengths, were investigated under various operating conditions …
-
Impact of Fluids Distribution System on Bubble Column Hydrodynamics
… depends on the fluids distribution system and liquid recycle pan. Given that bubbles do not readily coalesce in the bed, the original bubble size distribution generated at the bubble cap distributor likely impacts buoyancy-based phase separation at the recycle pan. Gas entrained in the liquid …
-
Wet scrubbing of biomass producer gas tars using vegetable oil
… wet packed bed scrubbing system includes a liquid distributor specifically designed to distribute a high viscous vegetable oil uniformly and a mixing section, which was designed to generate a desired concentration of tar compounds in a simulated air stream. A method and calibration protocol …
-
Gas absorption experiments in a pilot plant column with the sulzer structured packing mellapack
… are actually related to the overall volumetric liquid side mass transfer coefficient, which in turn is very close to kLa since O2 is sparingly soluble in water, even by comparison with CO2. Therefore the gas side resistance is negligible. The effective area for mass transfer and the kLa of the …
-
Biofilm development in a fluidized bed bioreactor for aerobic phenol degradation : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology in Biotechnology and Bioprocess Engineering at Massey University
… on phenol as sole carbon source in an aerobic liquid-solid fluidized bed bioreactor. The effect of different reactor temperatures and of different inlet phenol concentrations on the system behaviour during start-up was investigated. The phenol inhibition kinetics of the culture was studied in …
-
Untersuchungen zur Neuverteilung der Rücklaufflüssigkeit in Packungskolonnen
Bei der Rektifikation werden heute zunehmend Füllkörperkolonnen mit geordneten Packungen eingesetzt. Die Maldistribution, ein bislang ungelöstes Problem in Füllkörperkolonnen, wirkt sich negativ auf die Stoffaustauschleistung aus. Zur Verringerung der Maldistribution wird zwischen den …
-
Application of a non-equilibrium thermodynamics framework derived from nature-inspired themes for modelling and design of processes
… porte sur l’évaluation d’un distributeur de liquide pour une colonne à distiller. Cet interne de colonne consiste en un plateau avec des orifices, et des structures filaires sortant de ces orifices comme les branches d’un arbre. Le liquide s’écoule sur la surface de ces fils, se divisant en …