Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 7 of 7 for “"liquid distributor"”

  1. Impact of Bubble Characteristics and Particle Properties on the Fluid Dynamics of an Ebullated Bed Hydroprocessor

    … freeboard were simulated in a high pressure gas-liquid bubble column operating at 6.5 MPa using nitrogen and a 0.5 wt.% aqueous ethanol solution. Local bubble characteristics, including gas holdups, bubble rise velocities, and chord lengths, were investigated under various operating conditions …

    ottawa-retro Repository record for Impact of Bubble Characteristics and Particle Properties on the Fluid Dynamics of an Ebullated Bed Hydroprocessor (opens in a new tab)

  2. Impact of Fluids Distribution System on Bubble Column Hydrodynamics

    … depends on the fluids distribution system and liquid recycle pan. Given that bubbles do not readily coalesce in the bed, the original bubble size distribution generated at the bubble cap distributor likely impacts buoyancy-based phase separation at the recycle pan. Gas entrained in the liquid …

    ottawa-retro Repository record for Impact of Fluids Distribution System on Bubble Column Hydrodynamics (opens in a new tab)

  3. Wet scrubbing of biomass producer gas tars using vegetable oil

    … wet packed bed scrubbing system includes a liquid distributor specifically designed to distribute a high viscous vegetable oil uniformly and a mixing section, which was designed to generate a desired concentration of tar compounds in a simulated air stream. A method and calibration protocol …

    okstate Repository record for Wet scrubbing of biomass producer gas tars using vegetable oil (opens in a new tab)

  4. Gas absorption experiments in a pilot plant column with the sulzer structured packing mellapack

    … are actually related to the overall volumetric liquid side mass transfer coefficient, which in turn is very close to kLa since O2 is sparingly soluble in water, even by comparison with CO2. Therefore the gas side resistance is negligible. The effective area for mass transfer and the kLa of the …

    epfl Repository record for Gas absorption experiments in a pilot plant column with the sulzer structured packing mellapack (opens in a new tab)

  5. Untersuchungen zur Neuverteilung der Rücklaufflüssigkeit in Packungskolonnen

    Bei der Rektifikation werden heute zunehmend Füllkörperkolonnen mit geordneten Packungen eingesetzt. Die Maldistribution, ein bislang ungelöstes Problem in Füllkörperkolonnen, wirkt sich negativ auf die Stoffaustauschleistung aus. Zur Verringerung der Maldistribution wird zwischen den …

    qucosa-diss Repository record for Untersuchungen zur Neuverteilung der Rücklaufflüssigkeit in Packungskolonnen (opens in a new tab)

  6. Application of a non-equilibrium thermodynamics framework derived from nature-inspired themes for modelling and design of processes

    … porte sur l’évaluation d’un distributeur de liquide pour une colonne à distiller. Cet interne de colonne consiste en un plateau avec des orifices, et des structures filaires sortant de ces orifices comme les branches d’un arbre. Le liquide s’écoule sur la surface de ces fils, se divisant en …

    star-france Repository record for Application of a non-equilibrium thermodynamics framework derived from nature-inspired themes for modelling and design of processes (opens in a new tab)