Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 18 of 18 for “"liquid phantoms"”
-
Detection of Signal Parameters and Backscattering Polarimetric Imaging Signatures using Molecular Optical Contrast Agents and Preclinical Liquid Phantoms
The main purpose of this study is to explore the potential of optically active molecules in conjunction with single pixel detectors and polarimetric techniques for early detection of tissue pathologies. Optical polarimetry can provide invaluable biological information based on molecular composition …
-
Estimating Optical Properties of Liquid Phantoms with Multiple Correction Methods Using Measurements from a Single Integrating Sphere and the Inverse Adding-Double Algorithm
… will be explored using a robust set of optical phantoms whose properties mimic typical biological tissues. An analysis of the limitations of the system revealed light losses in IS measurements that translate to errors in inverse calculations. A robust Monte-Carlo model mimicking light …
-
Experimental studies of time-resolved light propagation in turbid media
… the optical properties of tissue-simulating liquid phantoms were determined using established techniques based on steady-state diffusion theory and Monte Carlo simulations. In the second section, time-resolved experiments were performed in homogeneous liquid phantoms of varying geometries, …
-
The development and validation of hybrid frequency- domain and broadband diffuse optical spectroscopy for monitoring tissue water content during hemodialysis
… was performed using mineral oil-based solid phantoms, deuterium oxide (D2O) liquid phantoms, and desiccating porcine tissue. The FD-Bb-SWIRS system was sensitive to changes in μa from varying concentrations of absorbers in solid and liquid phantoms. Ex vivo measurements of μa spectra …
-
Double Integrating Sphere Characterization of PVA-Cryogels
… setting, this is achieved through the use of phantoms, which mimic the physical characteristics of tissues. Polyvinyl alcohol (PVA), a non-toxic, water-soluble polymer is well-suited for use as clinical phantom material. Through successive freezing and thawing, solutions of PVA in water can be …
-
Cerebral oxygenation monitoring in neonates: improving and validating instrumentation
… sensors, we have performed several studies with liquid phantoms simulating optical properties of neonatal brain tissue. We first conducted experiments with a simple, homogeneous phantom and then refined the set-up to model a more realistic two-layer geometry resembling skull and brain. Our studies …
-
Flexible Silicon Photodiode Probes for Diffuse Reflectance Spectroscopy
… and malignant breast tissue representative liquid phantoms. DRS measurements were performed with the flexible DRS probe on both liquid phantoms over a wavelength range of 470 – 600 nm at five radii of curvature: flat, 50 mm, 25 mm, 15 mm, and 10 mm. The optical contrast between the benign …
-
Integrating sphere-based spectrally constrained total diffuse reflectance for in vivo quantification of hemoglobin in skin
… and then confirmed with tissue-simulating liquid phantoms. The model was tested for sensitivity and specificity, as well as how it responded to variations in the experimental parameters. The system and model were then used to monitor radiation-induced erythema in head and neck intensity …
-
Serotonin CEST: From In Vitro Characterization to In Vivo Detection
… to eliminate convection currents in warm liquid phantoms to accurately image in vitro samples under stable physiological temperature conditions. Serotonin and its precursor molecules (L-tryptophan and 5-HTP) exhibit significant and similar CEST contrast at both a pH of 5.5 (Δω = 2.64 – …
-
ENGINEERING TARGETED LIGHT ACTIVATABLE NANOPLATFORMS TO MANAGE RECURRENT CANCERS
… optical property (TOP) monitoring method for liquid phantoms and for peritoneal carcinomatosis mouse model to enable safer light dosimetry during PDT, established an irinotecan active loading method to reproducibly synthesize tLAMP, and determined tLAMP tumor nodule penetration depth for …
-
Tissue Identification and Photoablation Therapy Control with Contact Diffuse Reflectance Spectroscopy
… to differentiate two-colored synthetic optical phantoms was used to control a clinical excimer laser. To simulate an easy ablation procedure, five procedure experts were given the task of lasing only one color of the phantom. Each user ran through the procedure four times, twice with classifier …
-
NONINVASIVE MULTIMODAL DIFFUSE OPTICAL IMAGING OF VULNERABLE TISSUE HEMODYNAMICS
… both high and low BF contrasts in tissue-like phantoms and human forearms. In a wound imaging study using scDCT, significant lower BF values were observed in the burned areas/volumes compared to surrounding normal tissues in two patients with burn. One limitation in this study was the potential …
-
New multi-modal neuroimaging approaches combining photonics and electrophysiology to study the basics of neurovascular coupling
… through experiments on tunable tissue-mimicking liquid phantoms and through in-vivo experiments on rodents. This device has the potential for usage in studies focused on investigation of oxygen metabolism in the brain in future.
-
Multiplexed molecular imaging in the second near infrared window
… obtained with the commonly used Intralipid® liquid phantoms were analyzed with a quantitative pipeline, to evaluate the effect of various parameters in NIR-II imaging. Monte Carlo simulations were conducted to verify the findings. The NIR-II imaging was also applied on a tissue clearing …
-
Development of a Wide Field Diffuse Reflectance Spectral Imaging System for Breast Tumor Margin Assessment
… imaging system was tested in tissue-mimicking liquid phantoms and achieved comparable performance to previous clinically-validated fiber optics based systems in its ability to extract optical properties with high accuracy. The system was also tested in various biological samples, including a …
-
Exploiting Optical Contrasts for Cervical Precancer Diagnosis via Diffuse Reflectance Spectroscopy
… cervical epithelium. Mean extraction errors from liquid phantoms with optical properties mimicking the cervical epithelium for μa and μs' were 11.3 % and 12.7 %, respectively. Diffuse reflectance spectra from 9 sites in four loop electrosurgical excision procedure (LEEP) patients were analyzed. …
-
Spatially Resolved Diffuse Reflectance Spectroscopy of Intestinal Tissue Using Concentric Silicon Thin Film Photodiode Arrays
… sensors was initially evaluated on synthetic liquid tissue phantoms, with comparisons of the experimentally measured diffuse reflectance from these phantoms compared to Monte Carlo simulated diffuse reflectance, yielding a mean discrepancy of 8.4% over the 450 to 650 nm wavelength range. …
-
Development of Clinically Translatable Technologies for Optical Image-Guided Breast Tumor Removal Surgery
… system was tested on a set of tissue mimicking liquid phantoms which yielded an optical property extraction accuracy of 6.40 ± 7.78% for the absorption coefficient (µa) and 11.37 ± 19.62% for the wavelength-averaged reduced scattering coefficient (µs').</p><p>While DRS provided one potential …