Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 180 for “"load current"”.
-
Improved Models for DC-DC Converters
… is needed. It is suitable to consider the load to be included in the converter model since it usually affects the dynamics. The load is often the most variable part of this system. If the load current and the output voltage are measured there are good possibilities to obtain a good model of …
-
Multiple Input Single Output Converter with Uneven Load Sharing Control for Improved System Efficiency
… The premise of this thesis is to create uneven load current sharing between the converters at different loading conditions in order to maximize the efficiency of the overall MISO converter. The goal is to find a proper ratio of current from each converter to the total load current of the MISO …
-
Ultra-low Quiescent Current, Fast Settling Capacitor-less Low Drop-out Regulator
A 220 nA ultra-low quiescent bias current capacitor-less low drop-out (CL-LDO) regulator with improved single transistor control (STC) and adaptive transformation is presented in this thesis. The STC-LDO handles light load currents (0-20 uA), whereas the adaptive transformation to 2-stage structure …
-
DC-DC Converters - Dynamic Model Design and Experimental Verification
… a good model of the converter is needed. The load usually affects the dynamics and one way to take this into consideration is to regard the load as a part of the converter. The load is often the most variable part of this system. If the load current and the output voltage are measured there …
-
DETERMINATION OF TRANSMISSION LINE AMPACITIES BY PROBABILITY AND NUMERICAL METHODS
… distributed within a power system. The maximum load current that can be carried by the conductor is designated as the conductor ampacity and is normally determined from a single set of weather conditions. In recent years, it has been suggested that traditional ampacities are conservative and …
-
Current Source Inverter in Magnetohydrodynamic Drive for Marine Propulsion
This thesis presents the design of a full-bridge current-source inverter (CSI) as an AC magnetohydrodynamic drive. The inverter is built around a hybrid reverse-blocking switching unit composed of a normally-on SiC JFET in series with a SiC Schottky diode. The work includes the custom isolated …
-
Power conditioning in inductive energy storage systems
… part of the thesis deals with an analysis of the current Inductive Energy Storage System, concerning inductance and resistance, then build a basis to evaluate the measurements taken. Different fuse parameters, such as wire size, number of wires, and materials is discussed, and the influences of …
-
Multi-Objective Finite-Control-Set Model Predictive Control of Reduced-Component Multilevel Inverters
… some redundant switching states. Therefore, load-current tracking, flying-capacitor voltage regulation, and Common-Mode Voltage (CMV) mitigation can be achieved using a cost function specific to each topology. A discrete FCS-MPC formulation is developed in the natural abc reference frame. A …
-
Ultra Low Power Cap-Less LDO with Fast Startup
… LDO and regulates the output voltage during fast load transients. In order to save power based on the load conditions, the design uses two current detector circuits one for high slew rate and one for slow slew rate to turn on/off certain networks in the LDO depending on the load current. The LDO …
-
A Dual-Supply Buck Converter with Improved Light-Load Efficiency
… to their high efficiency, compact sizes and high current delivery capability. However portable devices usually operate at light loads most of the time and are only required to deliver high current in very short periods, while conventional buck converter suffers from low efficiency at light load …
-
Control de puentes activos duales (DABs) en sistemas bidireccionales de alimentación con alta densidad de potencia
… converter provide galvanic isolation, control current and / or voltage at one or both buses, and in some cases provide multi-port bidirectional conversion. One of the topologies with high power density is the single phase Dual Active Bridge (DAB). This thesis presents a study of a single phase …
-
Rating optimization of three phase series hybrid power filter for power quality compensation and renewable energy integration
… and ensure a reliable voltage supply to the load through mitigating or eliminating issues such as voltage distortions, sags, swells, and unbalances. They can also compensate current problems related to linear and non-linear loads, such as load reactive power, current harmonics. In this thesis …
-
Modeling and Control Design of a Bidirectional PWM Converter for Single-phase Energy Systems
… in renewable energy systems. There is a generic current loop for different modes of operation to ease the transition between different modes, including stand-alone inverter mode, grid-tied inverter mode, grid-tied rectifier mode and grid-tied charger/discharger mode. Under stand-alone mode …
-
A Fully Integrated High-Temperature, High-Voltage, BCD-on-SOI Voltage Regulator
… of operating under various input voltages and load currents. These input voltages and load currents can be either DC or time-varying signals. In this work, a stable supply voltage for embedded circuit functions is generated on chip via a voltage regulator circuit producing a stable 5-V output …
-
Ekonomiško mažos galios buck-boost įtampos keitiklio projektavimas /
… shown efficiency levels not lower than 75% when load current was as low as 2 microamperes and efficiency levels, near 90% which were observed when operating in high load currents, when load current is greater than 20 microamperes. The converter is able to maintain its configured output voltage …
-
Powers and Compensation in Three-Phase Systems with Nonsinusoidal and Asymmetrical Voltages and Currents
… of unbalanced Linear Time Invariant (LTI) loads at sinusoidal but asymmetrical voltage is first presented. The different current components of such a load and the phenomenon associated with these current components are described. The load current decomposition is used for the design of …
-
A Control Integrated Circuit for a Hysteretic Flyback Power Converter
… a normal operating temperature of 27°C, and a load current of 2.5A which resulted in an output voltage of 12.5V with a 350mV ripple voltage caused by the control loop’s hysteresis. The higher value of ripple in the output voltage was shown to be reduced with a larger, thus more expensive, …
-
Four-Output Isolated Power Supply for the Application of IGBT Gate Drive
… which relates the drop of output voltage to the load current. Then, the effects of the dc blocking capacitor for the unbalanced load condition and unbalanced duty cycle are tackled. The theoretical results are compared with the experimental results and the simulation results to verify the …
-
A Monolithic Masterless Fault-tolerant Hybrid Switched-capacitor Dickson Converter for 48-V Multi-phase Automotive Applications
… control scheme based on the valley-current on-time control, which enables masterless interleaving, current sharing, and self-balancing of the flying-capacitor voltages, 2) a fast and robust short-circuit and open-circuit fault detection of any power switches or flying capacitors, …
-
The Proposal for Implementation of Controlled Power Rectifier (3000/4000KW) in MTA New York City Transit (MTA-NYCT)
… These issues include input Alternating Current (AC) interface requirements, the output Direct Current (DC) load profile, and overall stability in the output voltage for Train car loads. Understanding these issues, providing possible solutions and determining the means of assuring smooth …
Page 1 of 9