  1. Load forecast uncertainty considerations in bulk electrical system adequacy assessment

    … requirement in this task is the ability to forecast the system load requirements at specific times in the future. These forecasts must also recognize the inherent uncertainty in predicting the future load demands. The primary focus of the research described in this thesis is to examine the …

    sask Repository record for Load forecast uncertainty considerations in bulk electrical system adequacy assessment (opens in a new tab)

  2. An analysis of short-term risk in power system planning.

    … are as follows: The impact of weather forecasts on Bayesian load forecasting as a function of forecast lead time is shown in Chapter 2. Risk in the presence of load forecast uncertainty alone and risk in the presence of load forecast uncertainty together with fuel price uncertainty are …

    oklahoma-thes Repository record for An analysis of short-term risk in power system planning. (opens in a new tab)

  3. Bulk electric system reliability evaluation incorporating wind power and demand side management

    … using the well-being analysis framework. Load forecast uncertainty is an important consideration in an electrical power system. This research includes load forecast uncertainty considerations in bulk electric system reliability assessment and the effects on system, load point and …

    sask Repository record for Bulk electric system reliability evaluation incorporating wind power and demand side management (opens in a new tab)

  4. MAINTENANCE SCHEDULING OF GENERATING FACILITIES IN SINGLE AND INTERCONNECTED POWER SYSTEMS

    … system and the variation in the system load has been developed. This technique levelizes the system risk throughout the year. A method for calculating the unit Effective Load Carrying Capability (ELCC) is introduced and a comparison of this method with the other methods reported in the …

    sask Repository record for MAINTENANCE SCHEDULING OF GENERATING FACILITIES IN SINGLE AND INTERCONNECTED POWER SYSTEMS (opens in a new tab)

  5. Assessment of spinning reserve requirements in a deregulated system

    … commits adequate generation to satisfy its load and export/import commitment. Additional generation known as spinning reserve is also required to satisfy unforeseen load changes or withstand sudden generation loss. In a vertically integrated system, a single entity generates, transmits and …

    sask Repository record for Assessment of spinning reserve requirements in a deregulated system (opens in a new tab)

  6. GENERATING CAPACITY RELIABILITY STUDIES OF SINGLE AND INTERCONNECTED SYSTEMS USING FREQUENCY AND DURATION ANALYSIS

    … the cumulative probability and frequency of a load loss situation. This approach uses the individual generating unit mean failure and repair rates in addition to the forced outage probability values and therefore the developed indices are sensitive to all of these values. This thesis …

    sask Repository record for GENERATING CAPACITY RELIABILITY STUDIES OF SINGLE AND INTERCONNECTED SYSTEMS USING FREQUENCY AND DURATION ANALYSIS (opens in a new tab)

  7. OPERATING RESERVE ASSESSMENT IN MULTI-INTERCONNECTED SYSTEMS

    … and unit commitment have been developed. Load forecast uncertainty, partial generating unit outage states, rapid start gas turbine and hot reserve generation and the assistance from- interconnections have also been included in the analysis. The incorporation of these factors in the …

    sask Repository record for OPERATING RESERVE ASSESSMENT IN MULTI-INTERCONNECTED SYSTEMS (opens in a new tab)

  8. "LOAD MODIFICATION" -- A NEW METHOD TO CALCULATE GENERATING CAPACITY RELIABILITY INDICES

    … is essentially a process of modifying a given load duration curve with a generating capacity distribution to give an equivalent load duration curve. This technique is called the 'Load Modification Approach'. This new method can be used to generate three reliability indices, namely, Loss of Load …

    sask Repository record for "LOAD MODIFICATION" -- A NEW METHOD TO CALCULATE GENERATING CAPACITY RELIABILITY INDICES (opens in a new tab)

  9. Adequacy assessment of composite generation and transmission systems incorporating wind energy conversion systems

    … concepts in system planning and decision making. Load forecast uncertainty is an important factor in long range planning and system development. This thesis describes two approximate approaches developed to reduce the number of steps in a load duration curve which includes load forecast …

    sask Repository record for Adequacy assessment of composite generation and transmission systems incorporating wind energy conversion systems (opens in a new tab)

  10. INCORPORATING GENERATING UNIT MAINTENANCE SCHEDULING IN POWER SYSTEM RELIABILITY EVALUATION

    … a percentage of the available capacity or load, or a value equal to the largest loaded unit. A hybrid approach designated as the health levelization technique that combines a probabilistic evaluation and an acceptable deterministic criterion into a single framework is described in this …

    sask Repository record for INCORPORATING GENERATING UNIT MAINTENANCE SCHEDULING IN POWER SYSTEM RELIABILITY EVALUATION (opens in a new tab)

  11. A PROBABILISTIC TECHNIQUE FOR OPERATING RESERVE ASSESSMENT USING SYSTEM OPERATING STATES

    … of factors such as lead time, system peak load, load forecast uncertainty and generating unit derated states are illustrated in this thesis. The inclusion of rapid start and hot reserve units and interruptible loads in the analysis can affect the GSOSR and the system operating state …

    sask Repository record for A PROBABILISTIC TECHNIQUE FOR OPERATING RESERVE ASSESSMENT USING SYSTEM OPERATING STATES (opens in a new tab)

  12. Operating health analysis of electric power systems

    … the margin time, required regulating margin and load forecast uncertainty are illustrated. The effects on the response well-being of rapid start units, interruptible loads and postponable outages are also illustrated. System well-being is, in general, greatly improved by interconnection with …

    sask Repository record for Operating health analysis of electric power systems (opens in a new tab)

  13. SPINNING RESERVE ASSESSMENT IN INTERCONNECTED GENERATION SYSTEMS

    … start and hot reserve units and interruptible loads can reduce the unit commitment risk for a given set of generation and load conditions. Rapid start and hot reserve units have been included in the time dependent risk calculation using the Area Risk Technique. The effect of load interruption …

    sask Repository record for SPINNING RESERVE ASSESSMENT IN INTERCONNECTED GENERATION SYSTEMS (opens in a new tab)

  14. Optimal Participation of Power Generating Companies in a Deregulated Electricity Market

    … spot energy market caters to unforeseen rise in load demand and thus commands a higher price for electrical energy than the day-ahead market. A generating company can improve its profit by using an appropriate bidding strategy. This improvement is affected by the nature of bids from competitors …

    sask Repository record for Optimal Participation of Power Generating Companies in a Deregulated Electricity Market (opens in a new tab)