Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 46 for “"loading device"”.

  1. Design of a dielectrophoretic cell loading device

    … This dissertation discusses the design of a device that loads cells suspended in a solution into microvials using a combination of dielectrophoresis and fluid flow, which offers significant advantages over previous loading approaches. The basic concept is to use fluid flow and …

    maryland Repository record for Design of a dielectrophoretic cell loading device (opens in a new tab)

  2. Development of an Ankle De-Loading Device Based on Stewart Platform

    This paper presents an ankle de-loading device based on a Stewart platform for ankle pain caused by Osteoarthritis (OA)/Rheumatoid Arthritis (RA) or ankle fracture surgery. The developed device aims to relieve the ankle pain by lifting the posterior section of the foot and distributing the ankle …

    auckland-tech Repository record for Development of an Ankle De-Loading Device Based on Stewart Platform (opens in a new tab)

  3. Design, Construction, and Testing of an Intermediate Strain Rate Loading Device for Synchrotron-Based Testing of Geological Materials

    … α- quartz. Instead of using a Kolsky bar based loading solution, a piezoelectric actuator driven system, PAIRLS (Piezo Actuated Intermediate Rate Loading System), has been developed to allow for acquisition of force and displacement data across the low and intermediate strain rate ranges. This …

    jhu Repository record for Design, Construction, and Testing of an Intermediate Strain Rate Loading Device for Synchrotron-Based Testing of Geological Materials (opens in a new tab)

  4. Design and Validation of a Dynamic Pressure-Based Loading Device and 3D Strain Tracking Protocol for Ventral Hernia Modeling

    … testing, which are not physiologically relevant loading environments. The need for a testing device that can exert physiologically relevant loads ex vivo to an abdominal wall is crucial for the development of more effective repair strategies and products. After abdominal hernia repairs, coughing …

    wustl Repository record for Design and Validation of a Dynamic Pressure-Based Loading Device and 3D Strain Tracking Protocol for Ventral Hernia Modeling (opens in a new tab)

  5. Design and validation of a cadaveric knee joint loading device compatible with magnetic resonance imaging and micro computed tomography

    … resonance and computed tomography compatible device capable of applying muscle forces to cadaveric knee joints with high precision. Methods: Load was applied to two porcine knee joints at full extension, five and fifteen degrees of flexion. Five repeatability and five reproducibility trials …

    guelph Repository record for Design and validation of a cadaveric knee joint loading device compatible with magnetic resonance imaging and micro computed tomography (opens in a new tab)

  6. Magnetic resonance elastography: a novel imaging technique to assess knee joint function using a bespoke loading device in patients undergoing total knee replacement

    … replacement (TKR). The development of a muscle loading device allowed investigation into the intricate relationship between antagonistic muscle groups to further our understanding of muscle co-activation and recruitment patterns during loading. The MRE data acquisition protocol and analysis …

    edinburgh Repository record for Magnetic resonance elastography: a novel imaging technique to assess knee joint function using a bespoke loading device in patients undergoing total knee replacement (opens in a new tab)

  7. Ability of Cylindrical Root Form Implants to Withstand Controlled Lateral Forces

    … for quantification of forces generated by a loading device have been developed and tested. The strain gages bonded to the loading device were calibrated either intraorally by a micro load cell, or in laboratory by Instrom Machine. Preliminary results indicate that laterally applied continuous …

    loma-linda Repository record for Ability of Cylindrical Root Form Implants to Withstand Controlled Lateral Forces (opens in a new tab)

  8. Obtaining Material Properties of the Plantar Soft Tissue for a Patient-Specific Finite Element Model of the Foot

    … resonance imaging (MRI) compatible, dynamic loading device that used cardiac-gated MRI imaging to obtain <italic>in vivo </italic>force versus deformation data for the plantar soft tissue. The resulting data will be used as inputs to an inverse finite element (FE) analysis to solve for soft …

    washington Repository record for Obtaining Material Properties of the Plantar Soft Tissue for a Patient-Specific Finite Element Model of the Foot (opens in a new tab)

  9. The Dynamic Low Cycle Testing Machine: (Design and Calibration)

    The design and development of a loading device for subjecting a reversed shear specimen to a pulsed dynamic load is described. The development includes calibration technique to confirm that design criteria had been met. A relationship between plastic deformation and peak tensile load is presented.

    unm Repository record for The Dynamic Low Cycle Testing Machine: (Design and Calibration) (opens in a new tab)

  10. REALISTIC CADAVER MECHANICAL TESTING & QUANTITATIVE MAGNETIC RESONANCE IMAGING FOR EVALUATING KNEES THROUGHOUT WALKING

    … and injury) affect joints’ mechanical loading. Thus, knees must be studied under realistic loading conditions. Unfortunately, due to joints’ complexity (geometry, mechanical properties and loading), current experimental methods seldom achieve this. Quantitative magnetic resonance …

    sask Repository record for REALISTIC CADAVER MECHANICAL TESTING & QUANTITATIVE MAGNETIC RESONANCE IMAGING FOR EVALUATING KNEES THROUGHOUT WALKING (opens in a new tab)

  11. Shear crack initiation and propagation in foam core sandwich structures

    … using the compact-tension-shear (CTS) test loading device. Foams of three different densities were tested. The CTS specimen was, in association with a special loading device, an appropriate apparatus for experimental mixed-mode fracture analysis. Experimentally obtained fracture toughness …

    soton Download PDF for Shear crack initiation and propagation in foam core sandwich structures (opens in a new tab)

  12. Delamination between self-assembled monolayers

    … The design and the construction of the loading device, including the Ultra High Vacuum chamber, are described in the second section. Finally, the analysis of the delamination between self-assembled monolayers using a semi-analytical method and a finite element method is presented. SAMs …

    texas Repository record for Delamination between self-assembled monolayers (opens in a new tab) Restricted access

  13. The compressive failure of aligned fiber composite materials

    … process in these materials. Compressive test devices that are currently in use often encounter difficulties with stress concentrations and instabilities. In addition, current micromechanical approaches have shown only moderate success in predicting the compressive strengths of these materials. …

    texas Repository record for The compressive failure of aligned fiber composite materials (opens in a new tab) Restricted access

  14. Characterization of delamination in silicon/epoxy systems

    Microelectronic devices are multilayered structures with many different interfaces. Their mechanical reliability is of utmost importance when considering the implementation of new materials. Linear elastic fracture mechanics (LEFM) is a common approach that has been used for interfacial fracture …

    texas Repository record for Characterization of delamination in silicon/epoxy systems (opens in a new tab)

  15. Assessment of knee cartilage mechanics using the magnetization transfer ratio

    … first, an electropneumatic compressive loading device was developed and validated to apply step compressive forces to cartilage specimens in a high-resolution small-bore 9.4 Tesla MRI scanner. Second, bovine tibiofemoral osteochondral samples were compressed using this device while …

    ubc Repository record for Assessment of knee cartilage mechanics using the magnetization transfer ratio (opens in a new tab) Download PDF for Assessment of knee cartilage mechanics using the magnetization transfer ratio (opens in a new tab)

  16. A Comparative Study of the Permanent Deformation of Aesthetic Polymer Brackets

    … steel ring. The assembly was then placed under a loading device. This loading device, used In a previous study22, removes variables such as bond adhesive strengths, and torsion of a wire used to deform the bracket slot. The bracket slot was loaded by the application of a biaxial load In order to …

    loma-linda Repository record for A Comparative Study of the Permanent Deformation of Aesthetic Polymer Brackets (opens in a new tab)

  17. A study of the effects of varying rates of loading on the consolidation of soil.

    … of this theory as associated with construction loading have been recognized by Schiffman in his approach to a mathematical solution. Marron initiated investigations into the validity of Schiffman's work, and it is the purpose of this investigation to further these studies. Testing was carried …

    nps Repository record for A study of the effects of varying rates of loading on the consolidation of soil. (opens in a new tab)

  18. UTILIZATION OF PNEUMATIC ARTIFICIAL MUSCLES TO STUDY EFFECTS OF LOAD HISTORY ON THE INTERVERTEBRAL DISC

    … were calibrated and integrated into a small loading device as an actuation mechanism. Next, various load histories were then applied on IVDs and gene expression was determined by qRT-PCR. Results show that discs with increased intradiscal pressure led increased expression of genes common to …

    maryland Repository record for UTILIZATION OF PNEUMATIC ARTIFICIAL MUSCLES TO STUDY EFFECTS OF LOAD HISTORY ON THE INTERVERTEBRAL DISC (opens in a new tab)

  19. Platelet rich plasma and mechanical loading in regenerative tendon repair

    … platelet rich plasma (PRP) and mechanical loading, on tendon healing.</p><p>The effects of PRP, a rich autologous source of growth factors, on tendon cells was studied by modelling important stages of tendon healing <em>in vitro</em>. Key parameters such as cellular migration, chemotaxis, …

    oxford Repository record for Platelet rich plasma and mechanical loading in regenerative tendon repair (opens in a new tab)

  20. Strategies for Improved Fire Detection Response Times in Aircraft Cargo Compartments

    … program. Detectors placed inside a Unit Loading Device (ULD) responded quickly to the array of fire sources. Thus, a further exploration of these observations is conducted including wireless technology along with an analysis of the effects of leakage rates on fire signatures inside ULDs. …

    maryland Repository record for Strategies for Improved Fire Detection Response Times in Aircraft Cargo Compartments (opens in a new tab)

Page 1 of 3