Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"locking compression plate"”.

  1. Mechanical Comparison of a Type II External Skeletal Fixator and Locking Compression Plate in a Fracture Gap Model

    … II external skeletal fixator (ESF) to a 3.5 mm locking compression plate (LCP) in axial compression, mediolateral, and craniocaudal bending in a fracture gap model. The hypothesis was that the Type II ESF would demonstrate comparable stiffness to the LCP. A bone simulant consisting of short …

    vt Repository record for Mechanical Comparison of a Type II External Skeletal Fixator and Locking Compression Plate in a Fracture Gap Model (opens in a new tab)

  2. The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5 mm Broad Locking Compression Plate when used in an Open Fracture Gap Model

    Locking compression plates (LCP) have gained increasing popularity in veterinary and human medicine for their versatility, combining the functions of both locking and conventional plating systems. LCP are frequently used in minimally invasive plate osteosynthesis (MIPO). MIPO aims to preserve …

    guelph Repository record for The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5 mm Broad Locking Compression Plate when used in an Open Fracture Gap Model (opens in a new tab)

  3. A Biomechanical Comparison of 3.5 Locking Compression Plate Fixation to 3.5 Limited Contact Dynamic Compression Plate Fixation in a Canine Cadaveric Distal Humeral Metaphyseal Gap Model

    … To compare the biomechanical properties of 3.5 locking compression plate (LCP) fixation to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model in static axial compression and cyclic axial compression and torsion. Study …

    vt Repository record for A Biomechanical Comparison of 3.5 Locking Compression Plate Fixation to 3.5 Limited Contact Dynamic Compression Plate Fixation in a Canine Cadaveric Distal Humeral Metaphyseal Gap Model (opens in a new tab)

  4. Biomechanical comparison of the 1.5mm locking compression plate with the 1.5 and 2.0mm mini-cuttable plates & Effect of bone-plate distance on the biomechanical properties of the 1.5mm locking plate

    … investigating the appropriateness of the 1.5mm locking compression plate (LCP) for repair of radial and ulnar fractures in miniature breed dogs. A retrospective study will review the current use and results of the mini-cuttable plates in miniature breeds while a biomechanical study compares the …

    guelph Repository record for Biomechanical comparison of the 1.5mm locking compression plate with the 1.5 and 2.0mm mini-cuttable plates & Effect of bone-plate distance on the biomechanical properties of the 1.5mm locking plate (opens in a new tab)

  5. Die Dynamisierung der winkelstabilen Plattenosteosynthese mit Hilfe der Dynamic Locking Screw (DLS) : ein experimentelle Studie an Schafen

    … von 0, 1 oder 3 mm Breite wurde mit einer Locking-Compression-Plate in Kombination mit den zu evaluierenden Dynamischen Kopfverrieglungsschrauben (DLS) refixiert. Der Heilungsverlauf wurde radiologisch in einem dreiwöchigen Rhythmus über sechs, beziehungsweise zwölf Wochen kontrolliert. Am …

    zurich

  6. The Biomechanics of Locking Plates used in a Supercutaneous Fashion

    … leading to the investigation of alternatives. Locking plates, such as the string of pearls (SOP) and locking compression plate (LCP), gain strength from the screw-plate interface. Although soft tissue disruption is required for placement on the bone, precise contouring is not necessary. The …

    guelph Repository record for The Biomechanics of Locking Plates used in a Supercutaneous Fashion (opens in a new tab)

  7. Examination of a new arthrodesis technique for equine cervical vertebrae

    … was performed using a ventrally placed locking compression plate. The case was followed and reported. A test modulus was developed to allow biomechanical testing of a single cervical vertebral articulation and the biomechanical properties of different implants were investigated. The …

    glasgow Download PDF for Examination of a new arthrodesis technique for equine cervical vertebrae (opens in a new tab)

  8. A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model

    … and stabilized with either a 6-hole Dynamic Compression Plate applied in compression or a 6-hole Locking Compression Plate. Pelves were tested in cantilever bending to failure and construct stiffness, yield load, ultimate load at failure, displacement at failure, and mode of failure compared. …

    guelph Repository record for A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model (opens in a new tab)

  9. Die Versorgung kindlicher und jugendlicher Schaftfrakturen der unteren Extremität

    … in Deutschland den Therapiestandard dar. Die Locking Compression Plate (LCP), als winkelstabile Plattenosteosynthese, ist ein etabliertes Verfahren zur übungsstabilen Versorgung von Schaftfrakturen des Erwachsenen und kann optional in minimal-invasiver Technik durchgeführt werden. Ziel der …

    fu-berlin Repository record for Die Versorgung kindlicher und jugendlicher Schaftfrakturen der unteren Extremität (opens in a new tab)

  10. Desenvolvimento e análise mecânica ex vivo de duas novas placas de reconstrução bloqueadas para fraturas cominutivas de rádio de Lobo-guará e fêmur de Tamanduá-bandeira

    … nas novas placas e em modelo de placa bloqueada Locking Compression Plate (LCP). Foram analisados carregamento máximo, rigidez, deslocamento e limite de escoamento em ensaio estático de bancada para as duas novas placas. No grupo do rádio de Lobo-guará foram realizadas simulações computacionais …

    brazil-ufv Repository record for Desenvolvimento e análise mecânica ex vivo de duas novas placas de reconstrução bloqueadas para fraturas cominutivas de rádio de Lobo-guará e fêmur de Tamanduá-bandeira (opens in a new tab)

  11. Mechanical Assessment of Veterinary Orthopedic Implant Technologies: Comparative Studies of Canine Fracture Fixation and Equine Arthrodesis Devices and Techniques

    … construct to a 3.5mm Limited Contact-Dynamic Compression Plate (LC-DCP/rod) construct using a canine femoral gap model. Paired canine femora were treated with 40mm mid-diaphyseal ostectomies and randomly assigned to CRIF/rod or LC-DCP/rod. Five pairs of constructs were tested in bending and …

    tamu Repository record for Mechanical Assessment of Veterinary Orthopedic Implant Technologies: Comparative Studies of Canine Fracture Fixation and Equine Arthrodesis Devices and Techniques (opens in a new tab)

  12. Ex vivo biomechanical comparison of reinforced locking plate design and locking compression plates applied in comminuted tibial fractures

    … The aim of study was to compare four designs of locking plates at biomechanical characteristics for the stabilization of experimentally induced comminuted tibial fractures in dog. Material and Methods: Pelvic limbs were harvested from sixteen dog cadavers. Paired tibiae were stripped of all soft …

    brazil-ufv Repository record for Ex vivo biomechanical comparison of reinforced locking plate design and locking compression plates applied in comminuted tibial fractures (opens in a new tab)

  13. Standardisierung der Schwingstrecke in einer winkelstabilen Plattenosteosynthese

    … has been demonstrated in numerous studies. Plate working length (PWL) has been identified as an essential discriminator of healing success. Insufficient control and inconsistent reporting of mechanical boundary conditions have hampered the development of a more comprehensive fracture …

    fu-berlin Repository record for Standardisierung der Schwingstrecke in einer winkelstabilen Plattenosteosynthese (opens in a new tab)

  14. Ergebnisse der Behandlung distaler Radiusfrakturen mit winkelstabiler, 3,5mm-T-LCP

    Die Behandlungsmöglichkeiten <br>von Frakturen des distalen Radius sind vielfältig, <br>einen „golden standard“ nach den Kriterien der <br>„evidenzbasierten“ Medizin gibt es nicht. Nach <br>der Literatur eignet sich zur Stabilisierung vieler <br>Frakturtypen die palmare Plattenosteosynthese. …

    freiburg-diss Repository record for Ergebnisse der Behandlung distaler Radiusfrakturen mit winkelstabiler, 3,5mm-T-LCP (opens in a new tab)