Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 58 for “"longitudinal relaxation time"”

  1. Rentgeno spinduliais paveiktų kalcio fosfatų kietojo kūno BMR spektroskopija /

    … spectra of the samples with different exposure times was not observed. Spin-lattice (T1) relaxation time measurements were performed using the saturation recovery method to detect the structural changes of the samples. Radiation-exposed CPP samples showed reduced relaxation times. For …

    vilnius Repository record for Rentgeno spinduliais paveiktų kalcio fosfatų kietojo kūno BMR spektroskopija / (opens in a new tab)

  2. Model-Based Reconstruction Methods for MR Relaxometry

    … reconstruction uses prior knowledge about the relaxation behavior of the longitudinal magnetization after a suitable magnetization preparation to generate a series of fully sampled k-spaces from a strongly undersampled acquisition. A Fourier transform results in a spatially resolved time course …

    wurz-thes Repository record for Model-Based Reconstruction Methods for MR Relaxometry (opens in a new tab)

  3. Atomic vapours filled hollow core photonic crystal fibre for magneto-optical spectroscopy

    … of the frequent atom wall collisions. Anti relaxation coating materials have been applied to the inner core wall and the longitudinal relaxation time has been measured in coated and uncoated fibres utilising a magneto optical technique. Additionally sub Doppler transparencies are …

    bath Repository record for Atomic vapours filled hollow core photonic crystal fibre for magneto-optical spectroscopy (opens in a new tab)

  4. Biomedical Nanocrystal Agents: Design, Synthesis, and Applications

    … separation. Most MRI contrast agents affect the longitudinal relaxation time (T1) and transverse relaxation time (T2) of water protons in the tissue and result in increased positive or negative contrast. Here, we report the optimization of r1 (1/T1) or r2 (1/T2) relaxivity dynamics with diameter …

    rice Repository record for Biomedical Nanocrystal Agents: Design, Synthesis, and Applications (opens in a new tab)

  5. SYNTHESIS, CHARACTERIZATION AND RELAXIVITY OF POLYMERIC GADOLINIUM CHELATES AS POTENTIAL MRI CONTRAST AGENTS

    … model for comparison with our novel agents. The longitudinal relaxation time (T <sub>1</sub> ) of these agents and of GdDTPA (Magnevist) were measured and plotted as 1/T <sub>1</sub> versus concentration. From these plots, relaxivity (R <sub>1</sub> ) was deduced. The R <sub>1</sub> for these …

    ohiolink Repository record for SYNTHESIS, CHARACTERIZATION AND RELAXIVITY OF POLYMERIC GADOLINIUM CHELATES AS POTENTIAL MRI CONTRAST AGENTS (opens in a new tab)

  6. Applications de la résonance magnétique nucléaire à la chimie des actinides et au retraitement des combustibles nucléaires.

    … advanced NMR techniques. The dispersion of the longitudinal relaxation time T1 of solvent nuclei with the magnetic field (NMRD) yields information on the magnetic properties of paramagnetic actinide ions. The sensitivity of NMR to the exact nature of the ground state of actinide ions is also …

    liege Repository record for Applications de la résonance magnétique nucléaire à la chimie des actinides et au retraitement des combustibles nucléaires. (opens in a new tab) Restricted access

  7. A statistical re-examination of the spoiled gradient recall echo equation in the analysis of data from DSC and DCE MR imaging procedures

    … the contrast agent concentration, the baseline longitudinal relaxation time constant, and relevant perfusion parameters. The unique recovery of parameters in the proposed method is established through identifiability analysis, and its performance is validated through both numerical simulations …

    cork Repository record for A statistical re-examination of the spoiled gradient recall echo equation in the analysis of data from DSC and DCE MR imaging procedures (opens in a new tab)

  8. Measurement of wall relaxation times of polarized 3He in bulk liquid 4He for the Neutron Electric Dipole Moment experiment

    … Since depolarized 3He will produce a background, relaxation of the polarized 3He, characterized by the probability of depolarization per bounce, Pd , was measured for materials that will be in contact with polarized 3He. Depolarization probabilities were determined from measurements of the …

    uiuc Repository record for Measurement of wall relaxation times of polarized 3He in bulk liquid 4He for the Neutron Electric Dipole Moment experiment (opens in a new tab)

  9. On the Simultaneous Quantification of Flow Velocities and Relaxation Constants Through Magnetic Resonance Fingerprinting

    … proposed technique, termed “Flow-MRF”, allows time-resolved velocities and relaxation constants to be quantified simultaneously, in shorter acquisition times than conventional MR-based velocimetry. The simultaneous quantification of both sets of parameters was achieved by formulating the …

    heid-diss Repository record for On the Simultaneous Quantification of Flow Velocities and Relaxation Constants Through Magnetic Resonance Fingerprinting (opens in a new tab)

  10. Caracterização estrutural de fármacos por RMN de sólidos e cálculos DFT: mefloquina e praziquantel

    … and in experiments with variation in contact time, the constants associated with crosspolarization dynamics, ă1Ā ÿ (hydrogen longitudinal relaxation time constant in the rotating reference frame) and ăÿÿ (cross-polarization time constant), were measured. With the GIPAW approach in Quantum …

    brazil-uerj Repository record for Caracterização estrutural de fármacos por RMN de sólidos e cálculos DFT: mefloquina e praziquantel (opens in a new tab)

  11. Development and optimisation of high-field MRI techniques

    … of the human brain within reasonable examination times. Susceptibility artefacts in echo planar imaging (EPI) are exacerbated at high fields. A novel technique (TWIST) was developed that reduces blurring, geometric distortion and drop-out in EPI using conventional hardware. Pairs of aliased images …

    ucl Repository record for Development and optimisation of high-field MRI techniques (opens in a new tab)

  12. Quantitative MRI for measuring myelin content in human spinal cord

    … to correlate with myelin content, namely the longitudinal relaxation time (T₁) and quantitative Magnetization Transfer (qMT) parameters, and we compare them with a large set of myelin sensitive MRI indices in the post mortem MS spinal cord. The thesis is structured as follows: chapter 1 states …

    ucl Repository record for Quantitative MRI for measuring myelin content in human spinal cord (opens in a new tab)

  13. Effects of Paramagnetic Minerals on Pore-Size Distribution in Shale

    … the matrix and infilling fluid shifts transverse relaxation (T2) to shorter time, resulting in imprecise classification of pore-sizes. In shale, details of the effects of paramagnetic and clay minerals that induce the internal gradients, are poorly understood. We measured a brine mixture with a …

    okstate Repository record for Effects of Paramagnetic Minerals on Pore-Size Distribution in Shale (opens in a new tab)

  14. On Simulations of Spin Interactions Applied for the Volumetric T1 Quantification by in vivo Magnetic Resonance Imaging at Ultra High Field

    … for the volumetric quantification of the longitudinal relaxation time T1 by ultra high field (UHF) magnetic resonance imaging (MRI) is introduced. It is based upon the prediction of the MR signal disturbances, due to static magnetic and RF field inhomogeneities as well as readout effects …

    heid-diss Repository record for On Simulations of Spin Interactions Applied for the Volumetric T1 Quantification by in vivo Magnetic Resonance Imaging at Ultra High Field (opens in a new tab)

  15. Determination of solution structure of anti-cancer drug etoposide by NMR and computer simulation

    … these hydroxide groups by H-bonding with water. Relaxation experiments were done to measure the longitudinal relaxation time and the whole molecular tumbling speed in solution (τc is 0.6 ns at 500 MHz). Higher than average T1 differences between wet sample and dry samples were observed for 4'-0H, …

    u-pacific Repository record for Determination of solution structure of anti-cancer drug etoposide by NMR and computer simulation (opens in a new tab)

  16. Investigation of NMR properties of gel volume change with magnetic resonance imaging

    … scale δω (perturber strength) of the system the relaxation behavior is categorized into five diffusion regimes. Two empirical models are proposed, one for the spin echo and the other the gradient echo sequence, to account for the relaxation dependence of such variables as sphere radius R, δω , …

    uiuc Repository record for Investigation of NMR properties of gel volume change with magnetic resonance imaging (opens in a new tab)

  17. Développement de méthodes de SRM à 4,7 T pour l'étude in vivo du métabolisme lipidique chez la souris.

    … majeure des lipides hépatiques (LOREEDE pour LOngitudinal RElaxation time Evaluation from Dynamic Equilibrium) a été développée, et validée au cours d'une étude préliminaire sur des objets-tests et in vivo sur modèles murins.

    star-france Repository record for Développement de méthodes de SRM à 4,7 T pour l'étude in vivo du métabolisme lipidique chez la souris. (opens in a new tab)

  18. Preserving hyperpolarised nuclear spin order to study cancer metabolism

    … exponential decay of the polarisation with the longitudinal relaxation time constant T1. This work aimed to improve the combination of hyperpolarisation and metabolic NMR/ MRI by extending the observation timescale of the technique. Working with quantum mechanical properties of the detected …

    cambridge Repository record for Preserving hyperpolarised nuclear spin order to study cancer metabolism (opens in a new tab)

  19. Novel T1-Weighted Imaging Methods in Magnetic Resonance Imaging: From an Anthropomorphic Brain Phantom to a Spiral Pulse Sequence

    … contrast which is based on the spin-lattice or longitudinal relaxation time is mainly used to acquire structural details of the imaging objects. In my PhD studies, I focused on improving some of the limitations of T1-weighted imaging. First of all, there is a significant difference between …

    hawaii Repository record for Novel T1-Weighted Imaging Methods in Magnetic Resonance Imaging: From an Anthropomorphic Brain Phantom to a Spiral Pulse Sequence (opens in a new tab)

Page 1 of 3