Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 133 for “"low coherence"”.
-
Techniques for low coherence pulsed Doppler lidar
… currently used. These are required to ensure coherence is maintained between the reference and measurement beams over long pathlength differences. In order to reduce the cost and size of lidar systems, we have developed new lidar design philosophies based on using components that are cheaper …
-
Propagation of low-coherence fields in inhomogeneous media
Doctor of Philosophy (Ph.D.)
-
Optimization-Based Approaches to Low-Coherence Optical Diffraction Tomography
… and adapting them to new applications by use of low-coherence broadband illumination. First, I developed a method for ODT reconstruction using regularized convex optimization with a new phase-based fidelity criterion. The new criterion is necessary because objects with very different …
-
Low coherence fibre interferometry with a multi-wavelength light source
… the results of study of the multi-wavelength low coherence fibre interferometry. The development and performance of the all-fibre interferometric measurement systems utilising multi-wavelength combination sources are described. Principal aspects of the low-coherence sensor interrogation scheme …
-
Diagnostic Imaging and Assessment Using Angle Resolved Low Coherence Interferometry
… the development of new instruments based on low coherence interferometry (LCI) is presented in order to perform precise, depth-resolved measurements of scattered fields. Combined with LCI, the application of new light scattering models based on both analytic and numerical methods is presented …
-
Clinical Detection of Dysplasia Using Angle-Resolved Low Coherence Interferometry
… such optical biopsy technique, angle-resolved low coherence interferometry (a/LCI), its adaptation to a clinical technology, and its evaluation in clinical studies.</p><p> The dissertation presents the theory that underlies the operation of the a/LCI technique, the design and validation of the …
-
Novel Low Coherence Interferometric Tools for Early Detection of Cancer
… cervical and colorectal cancer, exhibit very slow growth and histological evidence on or close to the tissue surface of precancerous development. With appropriate methods, the cancer can be detected before it has the chance to actually become malignant, and safely removed, preventing additional …
-
Quantifying tympanic membrane dynamics in otitis media using low coherence interferometry
… analysis of the TM dynamics, a pneumatic low-coherence interferometry (LCI) otoscope was developed with automated pressure generation. The pneumatic LCI system developed during this research measures the TM displacement with an axial resolution of around 6.5 μm, and provides simultaneous …
-
Low coherence fibre optic Fabry-Perot sensors suitable for multiplexed strain measurement
… contains an investigation of the potential of low finesse in-fibre Fabry-Perot interferometer sensors for the measurement of strain. There are a number of areas of modern engineering applications where there is a need for an alternative to conventional resistive strain gauges; particularly …
-
Optical low coherence reflectometery for morphological characterization of static and dynamic systems
… dissertation I describe and evaluate Optical Low Coherence Reflectometery (OLCR) for morphological characterization of static and dynamic scattering systems.OLCR is a white-light interferometric technique, developed in the mid-1980s to measure the amplitude and the signal loss due to discrete …
-
MINIATURE LOW-COHERENCE FIBER OPTIC ACOUSTIC SENSOR WITH THIN-FILM UV POLYMER DIAPHRAGM
A miniature low-coherence fiber optic acoustic sensor with a thin-film UV polymer diaphragm is developed and studied in this thesis to address the fundamental challenge of miniaturizing acoustic sensors. When miniaturizing an acoustic sensor, there is a critical size limitation at which the …
-
Biomedical applications of a fiber based low-coherence interferometer for quantitative differential phase measurements
… based phase sensitive optical low-coherence reflectometer (PS-OLCR). Using dual channels, PS-OLCR detects Angstrom/nanometer scale optical path length changes by calculating phase difference between depth resolved interference fringes. Ability to detect such small changes in …
-
Novel fibre-optic-based interferometric sensors exploiting coherent and low-coherence signal processing techniques
… strain measurement is demonstrated using a short coherence length light source. A novel signal processing technique, based on either tracking the point of maximum visibility (zero path imbalance) or the first quadrature point, has been introduced. The advantages of both techniques are that the …
-
Light scattering and absorption spectroscopy in three dimensions using quantitative low coherence interferometry for biomedical applications
… demonstrates novel tools derived from low coherence interferometry (LCI) that quantitatively measure wavelength-dependent scattering and absorption properties of biological samples, with high spectral resolution and micrometer spatial resolution, to provide insight into disease states. …
-
Development of a Fourier Domain Low Coherence Interferometry Optical System for Applications in Early Cancer Detection
… of one such technique called Fourier domain low coherence interferometry (fLCI). </p><p>The presented work first describes a detailed analysis of temporal and spatial coherence. The study shows that temporal coherence information in time frequency distributions contains valuable structural …
-
The application of low coherence interferometry to the micron scale imaging of the living human retina
… about 300 pm. A new imaging technique, based on low coherence interferometry, providing improved depth resolution figures of the order of a few microns, is demonstrated here. Non-invasive topographic and tomographic measurements can be performed with an instrument based on this technique. A novel …
-
Non-invasive assessment of biofilm growth in the middle ear using a portable low-coherence interferometry system
… be recognized using a regular otoscope. However, lowcoherence interferometry (LCI) is capable of detecting and quantifying this microstructure. The goal of this research was to design a portable system integrating LCI with a standard video otoscope to detect the presence of biofilms and provide …
-
Combined Low-Cost Balanced Detection Optical Coherence Tomography and Angle-Resolved Low Coherence Interferometry Towards Alzheimer’s Disease Screening
… requirements of commercial optical coherence tomography (OCT) systems. This dissertation addresses these two distinct needs through the development of cost-conscious retinal imaging technology and the extension of retinal measurement beyond structural morphology toward …
-
Non-invasive assessment of bacterial biofilm in the middle ear using low-coherence interferometry/optical coherence tomography and acoustic measurements
… biofilm in the middle ear using two methods, low coherence interferometry (LCI)/optical coherent tomography (OCT) and acoustic measurements. Portable systems were constructed by integrating LCI/OCT techniques with a standard video otoscope to provide depth-resolved optical scattering …
Page 1 of 7