Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 45 for “"low-coherence interferometry"”.
-
Diagnostic Imaging and Assessment Using Angle Resolved Low Coherence Interferometry
… the development of new instruments based on low coherence interferometry (LCI) is presented in order to perform precise, depth-resolved measurements of scattered fields. Combined with LCI, the application of new light scattering models based on both analytic and numerical methods is presented …
-
Clinical Detection of Dysplasia Using Angle-Resolved Low Coherence Interferometry
… such optical biopsy technique, angle-resolved low coherence interferometry (a/LCI), its adaptation to a clinical technology, and its evaluation in clinical studies.</p><p> The dissertation presents the theory that underlies the operation of the a/LCI technique, the design and validation of the …
-
Quantifying tympanic membrane dynamics in otitis media using low coherence interferometry
… analysis of the TM dynamics, a pneumatic low-coherence interferometry (LCI) otoscope was developed with automated pressure generation. The pneumatic LCI system developed during this research measures the TM displacement with an axial resolution of around 6.5 μm, and provides simultaneous …
-
Light scattering and absorption spectroscopy in three dimensions using quantitative low coherence interferometry for biomedical applications
… demonstrates novel tools derived from low coherence interferometry (LCI) that quantitatively measure wavelength-dependent scattering and absorption properties of biological samples, with high spectral resolution and micrometer spatial resolution, to provide insight into disease states. …
-
Development of a Fourier Domain Low Coherence Interferometry Optical System for Applications in Early Cancer Detection
… of one such technique called Fourier domain low coherence interferometry (fLCI). </p><p>The presented work first describes a detailed analysis of temporal and spatial coherence. The study shows that temporal coherence information in time frequency distributions contains valuable structural …
-
The application of low coherence interferometry to the micron scale imaging of the living human retina
… about 300 pm. A new imaging technique, based on low coherence interferometry, providing improved depth resolution figures of the order of a few microns, is demonstrated here. Non-invasive topographic and tomographic measurements can be performed with an instrument based on this technique. A novel …
-
Non-invasive assessment of biofilm growth in the middle ear using a portable low-coherence interferometry system
… be recognized using a regular otoscope. However, lowcoherence interferometry (LCI) is capable of detecting and quantifying this microstructure. The goal of this research was to design a portable system integrating LCI with a standard video otoscope to detect the presence of biofilms and provide …
-
Combined Low-Cost Balanced Detection Optical Coherence Tomography and Angle-Resolved Low Coherence Interferometry Towards Alzheimer’s Disease Screening
… requirements of commercial optical coherence tomography (OCT) systems. This dissertation addresses these two distinct needs through the development of cost-conscious retinal imaging technology and the extension of retinal measurement beyond structural morphology toward …
-
Non-invasive assessment of bacterial biofilm in the middle ear using low-coherence interferometry/optical coherence tomography and acoustic measurements
… biofilm in the middle ear using two methods, low coherence interferometry (LCI)/optical coherent tomography (OCT) and acoustic measurements. Portable systems were constructed by integrating LCI/OCT techniques with a standard video otoscope to provide depth-resolved optical scattering …
-
Novel Low Coherence Interferometric Tools for Early Detection of Cancer
… cervical and colorectal cancer, exhibit very slow growth and histological evidence on or close to the tissue surface of precancerous development. With appropriate methods, the cancer can be detected before it has the chance to actually become malignant, and safely removed, preventing additional …
-
Development of Multimodal Optical System Guided by Optical Coherence Tomography
… light scattering techniques using optical coherence tomography (OCT) to improve clinical diagnosis. OCT is a non-invasive optical imaging technique that utilizes low coherence interferometry to detect reflected and scattered light from a sample to produce depth resolved images. OCT is an …
-
Novel Biophotonic Imaging Techniques for Assessing Women's Reproductive Health
… imaging of fluorimetry and multiplexed low coherence interferometry (mLCI) to measure in vivo microbicide gel thickness distributions. The study explores the optical performance of the device and provides proof of concept measurements on a calibration socket, tissue phantom, and in vivo …
-
HYBRID COMPUTATIONAL AND HARDWARE METHODS FOR OPTICAL COHERENCE TOMOGRAPHY
Optical coherence tomography is an emerging technique for performing noninvasiveoptical biopsy of tissue with micron level resolution via low coherence interferometry. Recently, as the demand is growing for high throughput and deep imaging, OCT seems to become a good candidate to accomplish these …
-
Development of Optical Technologies for Comprehensive Screening of Cervical Epithelial Health
… detection of cervical dysplasia: angle-resolved low coherence interferometry (a/LCI) and multiplexed low coherence interferometry (mLCI). Originally, a/LCI was developed as a clinical technique for detecting esophageal dysplasia by detecting nuclear enlargement in the basal layer of the …
-
Polymerisation kinetics and optical phenomena of photoactive dental resins
… The development techniques that will allow dynamic monitoring of optical and physical change will aid material development with the goal of improving cure depths. The current investigation has demonstrated the use of several analytical techniques (FT-IR spectroscopy, UV-Vis Spectroscopy …
-
Interrogation of fibre optic sensors
… grating, an acousto-optic tuneable filter and low-coherence interferometry to measure dynamic strain and displacement using fibre Bragg grating and interferometric sensors. Based on the intrinsic properties of arrayed waveguide gratings and acousto-optic tuneable filters used in conjunction …
-
Advanced systems and methods for collecting accurate data in optical coherence tomography
Optical coherence tomography (OCT) has recently emerged as a valuable technique in biomedical research and medical diagnostics. OCT based instruments allow acquisi- tion of high-resolution information about the internal structure of translucent organs and tissues without damaging the object. …
-
Arsenic Trisulfide on Lithium Niobate Waveguides for Nonlinear Infrared Optics
… semiconductor fabrication techniques, due to its lower refractive index and large transmission range (0.42-5.2 μm). Since low loss As_(2)S_(3)-on-LiNbO_(3) waveguides have been developed, it is a good time to exploit its applications in mid-IR wavelength. We illustrate the application of …
-
Three-Dimensional Imaging Techniques for Biomedical Applications
… Chromatic confocal microscopy and Optical Coherence Tomography (OCT) stand out as two techniques offering high-resolution, non-invasive 3D visualization of living tissues and organisms. Chromatic confocal microscopy utilizes longitudinal chromatic aberration to conduct depth scans, …
Page 1 of 3