Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 77 for “"low-dose-rate"”.
-
Investigation of a Monte Carlo model based dose calculation for Pd-103 low dose rate breast brachytherapy and I-125 low dose rate prostate brachytherapy
… inhomogeneities. Monte Carlo (MC) model-based dose calculation algorithms (MBDCA) provide improved dosimetric accuracy. The purpose of this work was to quantify the impact of eb_gui, a Canadian developed, user-friendly MC MBDCA, on plan evaluation with 80 low dose rate (LDR) breast …
-
Commissioning of the Canadian Primary Standard for Low Dose Rate Brachytherapy
… ionization chamber was then carried out with a low-energy X-ray beam (31 keV) where the air kerma rate had been previously established using the existing NRC primary standard free-air chamber. Agreement between the two devices was obtained within the combined measurement uncertainties of less …
-
Skeletal Impacts of Continuous Low-Dose-Rate Gamma Radiation Exposure During Simulated Microgravity
… unknowns in human spaceflight is the effects of low-dose-rate galactic cosmic radiation (GCR). The majority of radiation studies deliver the total radiation dose expected on a 2-3 year mission in minutes. However, timing of radiation delivery is known to be biologically relevant. Very few studies …
-
Untersuchung zum Migrationsverhalten von zwei verschiedenen Seedmodellen bei der permanenten Low-Dose-Rate-Therapie des Prostatakarzinoms
Eines der gängigen Behandlungsmethoden beim Prostatakarzinom im frühen Stadium ist die permantente Implantation von radioaktiven Seeds. Zwischen 20 und 80 dieser Iod-125 Strahler werden unter Spinal- oder Vollanästhesie in den Patienten dauerhaft implantiert. Die Implantation erfolgt unter …
-
Intraoperative use of c-arm cone beam CT for quality assurance of low dose rate prostate brachytherapy dose delivery
… assess implant quality, but do not provide accurate quantitative dosimetry. Thus, the patient undergoes a CT scan after the implantation is completed for dosimetric evaluation. However, this practice is not ideal as it occurs after the patient has left the operating room, when there is no longer …
-
Characterization of the Neutron Irradiation System for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories
… for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three recycled 241AmBe sources of different activities that had been combined into a single source. The source in its polyethylene shielding …
-
Towards improving prostate cancer diagnosis and treatment with shear wave absolute vibro-elastography and automatic low-dose-rate prostate brachytherapy planning
… time, this framework provides fast and accurate TTMB core localization. The pathology of these registered cores can serve as ground truth for training US-based PCa classifiers. To improve diagnosis, three US systems are developed to perform Shear Wave Absolute Vibro-Elastography (S-WAVE), a …
-
Fast Monte Carlo Cell-By-Cell Simulation of Radiation-Induced DNA Damage, Chromosome Aberrations, and Cell Death for Low-Dose-Rate Brachytherapy Sources
… an extension of the TOPAS modeling tool, allows the generation of standard DNA damage (SDD) files on a particle-by-particle and cell-by-cell basis. MEDRAS, a mechanistic DNA repair and survival model, is capable of calculating various types of chromosome aberrations and determining whether a …
-
Comparison of radiobiological endpoints in cells from CXB RI mice
… two inbred mouse strains (progenitor strains) followed by at least 20 generations of brother-sister inbreeding. Thus, RI strains are inbred (homozygous at every locus) and derive roughly half their genome from each of the two progenitor strains. The CXB RI strain set consists of 13 RI strains …
-
Characterizing the Immune Cell Transcriptomic Response to Sustained Low Dose Ionizing Radiation Exposure
This study investigates the effects of sustained low dose ionizing radiation (LDIR) exposure on the murine immune system, focusing on the molecular mechanisms and cellular responses to low dose rate whole-body 𝛾-radiation. Female C57BL/6 mice were continuously exposed to low dose rate 60Co …
-
RADIATION-INDUCED CHROMOSOME INSTABILITY AND INTERCELLULAR COMMUNICATION: THE ROLE OF DOSE RATE AND IMPLICATIONS FOR CARCINOGENESIS
The biological risks associated with low dose and low dose rate (LDR) radiation exposures are not yet well characterised. Experimental studies indicate that in addition to biological effects resulting from direct DNA damage, a variety of non-DNA targeted effects (NTE) including radiation-induced …
-
Adaptive responses to ionizing radiation in normal human skin fibroblasts.
… human skin fibroblasts (AG1522) pre-exposed to low-dose-rate ionizing radiation (IR) became less susceptible to the lethal effect of a subsequent acute challenge dose of radiation. A threshold and an optimum adapting dose were observed. This adaptive response (AR) at the survival level was …
Page 1 of 4