Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 7 of 7 for “"low-level outlet"”

  1. Air Demand in Low-Level Outlet Works

    Most dams have a low-level outlet that consists of a closed conduit through the dam with a slide gate or valve to regulate flow. These outlets are used mainly for irrigational purposes but also for flushing the reservoir and controlling the reservoir elevation. When discharging through the …

    utahstate Repository record for Air Demand in Low-Level Outlet Works (opens in a new tab)

  2. Air Vent Sizing in Low-Level Outlet Works for Small- to Medium-Sized Dams

    The majority of dams contain low-level outlet works, which typically consist of closed conduits that run through the dam, and are used to release water from the reservoir when the water level is below the level of the surface spillways. It is also used to flush the reservoir of sediments and to …

    utahstate Repository record for Air Vent Sizing in Low-Level Outlet Works for Small- to Medium-Sized Dams (opens in a new tab)

  3. Generation of Supersaturated Total Dissolved Gas at Submerged Hydropower Low-level Outlets

    … has been recorded that fish exposed to high TDG levels may suffer gas-bubble disease. The generation of high level TDG has been mostly studied downstream of spillways with very little attention to its generation related to low-level outlets, which is typically considered to be free from air …

    alberta Repository record for Generation of Supersaturated Total Dissolved Gas at Submerged Hydropower Low-level Outlets (opens in a new tab)

  4. Influence of outlet discharge on the efficiency of turbidity current venting

    … venting of turbidity currents through bottom outlets is an appealing solution to reduce reservoir sedimentation. Using a flume of 8.55 m length and 0.27 m width, venting was investigated experimentally and numerically. Governing parameters such as the bottom outlet's discharge, the timing of …

    epfl Repository record for Influence of outlet discharge on the efficiency of turbidity current venting (opens in a new tab)

  5. Aeration and two-phase flow characteristics of low-level outlets

    Low-level outlets are key safety elements of high-head dams. Their main purposes are the regulation of the reservoir water level for maintenance works or during floods, and the fast reservoir drawdown in case of imminent danger or structural damage of the dam. Furthermore, low-level outlets allow …

    ethz Repository record for Aeration and two-phase flow characteristics of low-level outlets (opens in a new tab)

  6. Modelling the thermal regime of a regulated coastal British Columbia river and assessing the potential of warming mitigation strategies

    … salmonid species begin their spawning runs. Following June 14, a steady discharge of approximately 2.7 m³/s was released from the reservoir through a low level outlet. The reservoir developed two-layer stratification and an internal seiche that caused oscillating withdrawal of epilimnetic and …

    ubc Repository record for Modelling the thermal regime of a regulated coastal British Columbia river and assessing the potential of warming mitigation strategies (opens in a new tab)

  7. Total Dissolved Gas Generation at Hugh L. Keenleyside Dam, B.C., Canada

    … of spill structures were studied, spillways, and low-level outlets. Several predictive models from the literature were modified and tested for the structures at the dam to better understand their wider applicability and to bring insight into this dam’s unique ability to dissolve gas. It was found …

    alberta Repository record for Total Dissolved Gas Generation at Hugh L. Keenleyside Dam, B.C., Canada (opens in a new tab)