Results 1 to 16 of 16 for “"lumbar spine model"”
-
Towards Real-Time Simulation of a Finite Element Generic Lumbar Spine Model
Real-time simulation of biomechanical models has provided exciting potential for improving the outcomes of some medical interventions by allowing clinicians to visualize the displacements and strains of biomechanical tissues in real-time during the intervention. Through real-time visualization, the …
-
Development and Validation of an Analogue Lumbar Spine Model and its Integral Components
… for an anatomically and mechanically correct model of the human lumbar spine. Such a model could have widespread use in the development of new implants and surgical procedures designed to remediate low back pain. Previous work has already been completed on such a model, and the purpose of this …
-
Control of the Mechanical Properties of the Synthetic Anterior Longitudinal Ligament and its Effect on the Mechanical Analogue Lumbar Spine Model
… of an anatomically correct mechanical analogue spine model would serve as a valuable tool in helping researchers and implant designers understand and alleviate low back pain. Advanced composite ligaments were designed to mimic the tensile mechanical properties of human spinal ligaments. By …
-
Validation of a Lumbar Spine Fracture Injury Criterion for Finite Element Human Body Model Simulations
… crash data reveal that the risk of thoracic and lumbar spine fractures has not experienced a similar decline. This discrepancy may be attributed to the fact that thoracic and lumbar spinal injuries are not adequately assessed in vehicle safety regulations and consumer testing programs, …
-
Reconstruction of the entire lumbar spine from partial information using Statistical Shape Models
Lumbar facet joint injections (LFJIs) are the standard of care in diagnosing the sources of and treating low back pain. The current gold standard for LFJIs is manually performed under fluoroscopic guidance. The main disadvantage is that it exposes both clinicians and patients to radiation hazards. …
-
Validation Testing of a Synthetic Spine and Upgraded Protocol for a Biomechanical Evaluation of a Lumbar Spinal Orthosis
… DMO success was upgraded with a new synthetic lumbar spine model. The latest generation of the DMO project was then evaluated using the new system in a laboratory setting and on a pilot physical therapy patient.First, a biomechanical evaluation study of the new full-length synthetic lumbar …
-
Finite Element Analysis of Lattice-Designed Interbody Cage in Lumbar Spine
… of interbody spinal cages using a modified lumbar spine model. The model is based on the anatomically detailed and previously validated Total Human Model for Safety (THUMS), which is adapted to replicate spinal fusion at the L4–L5 segment. This setup enables the analysis of various cage …
-
Design and Development of an Unconstrained Spine Test Rig to Study the Kinematics of Spine Motion
The spine is one of the most complex structures in the musculoskeletal system. Surgical procedures and implants used to treat spinal disorders include modification or removal of the diseased intervertebral disk, vertebral fusion using various combinations of hardware devices, and total disc …
-
Effects of Slips and Trips on Resultant Lumbar Kinematics, Lumbar Muscle Activity and Low-Back Loads
… (a harness prevented a fall). A biomechanical model developed using the AnyBody modeling software yielded trunk kinematics and muscle geometry. These outputs - along with the electromyography of fourteen lumbar flexor and extensor muscles - were employed as input data for our 3D, dynamic, …
-
Characterization of Thoracolumbar Fascia Anisotropy and the Mechanical Consequences of Tissue Disruption: An Experimental and Computational Study
… and growing evidence suggests that the thoracolumbar fascia (TLF) may play a significant role in underlying pain mechanisms. The TLF is mechanically integrated with the paraspinal muscles and abdominal wall and functions to transmit forces that stabilize the lumbar spine. Despite its anatomical …
-
Developing Lumbar Spine Fracture Injury Risk Functions for Frontal Impact Anthropomorphic Test Devices using Paired Human Body Model Simulations
Thoracolumbar fractures from car crashes have gained importance over the past halfcentury. While fatal injuries have declined due to vehicle structural- and infrastructural improvements, the rate of moderate and more severe thoracolumbar fractures has remained steady or slightly increased. Recent …
-
A Method to Describe Coactivation for the Lumbar and Cervical Spine
… aim was to develop coactivation indices for the lumbar and cervical spine to describe the physiological `cost’ of complex dynamic loads as a multiple-muscle system. The first phase involved the development of a coactivation index using a biologically-assisted lumbar spine model. Individual moment …
-
The Biochemical Response to Biomechanical Loading on the Low Back during Physical Work Exposure
… responses through advanced biomechanical modeling techniques. </p><p>Twelve healthy male subjects completed three sessions of experimental tasks (control, lifting and lowering 5 lbs and 25 lbs for 2 h at a frequency of 12 exertions per minute). Blood was sampled before, immediately after, …
-
The Impact of Unique Vertebral Geometry on Biomechanical Modeling of the Ligamentous Spine
Biomechanical spine models are useful tools in the field of musculoskeletal research but must be properly assembled and validated in order to provide the most accurate estimations. A lumbar spine model typically consists of the vertebrae, intervertebral disc, and the spinal ligaments; however, the …
-
Lumbar spine kinematics and kinetics during heavy barbell squat and deadlift variations
… within each lift, for their effects on lumbar spine kinematics and kinetics. The techniques compared within the deadlift condition were the low-hip deadlift (LHDL) and the high-hip deadlift (HHDL). The techniques compared within the squat condition were the high-bar squat (HBS) and …
-
Development of novel spine biomechanical analogue and digital models towards realizing a robotic spine simulator
… using cadaveric tissues, and in silico modeling through computational design and simulation tools represent the three principal methodologies commonly employed in the literature to investigate spine biomechanics. While in vivo and ex vivo studies are considered the gold standards in …