Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 29 for “"magnetic probe"”.
-
Inductive magnetic probe diagnostics in a plasma.
Inductive magnetic probes were studied, designed, constructed, calibrated and used at the Plasma Study Facility. The probes were built for three specific purposes: to measure current, radial shock waves and Alfven waves in a fast Theta Pinch; to measure the parameters of shock fronts with short …
-
Limitations of magnetic probe measurements in pulsed discharges
A "gradient probe" consisting of two search coils has been developed to measure the current density in a pulsed plasma. This probe measures both the magnitude and the gradient of the magentic field simultaneously enabling more accurate measurements than the conventional magnetic probe which has …
-
Optimization of magnetic probe measurements in transient plasmas
A significant improvement in magnetic probe measurements has been achieved by developing a 3-coil magnetic probe which partially corrects for the boundary error, i.e. for the error caused by an exclusion of the plasma current from the space occupied by the probe. The spatial resolution C of the …
-
Analysis of railgun magnetic probe signals to determine the plasma armature current distribution
… functional form of a plasma armature from B-dot probe signals. The B-dot probe signal is shown to be a convolution of the armature current density with the B-dot probe impulse response. The methods described here were developed utilizing the knowledge that the probe signal is a convolution. The …
-
Two-Chord Digital Holographic Interferometry on Sheared-Flow-Stabilized Z-Pinch Plasma
… made with pinch current centroid estimated from magnetic probe array. Field of view limitations and signal noise of the DHI setup are discussed. Suggestions are made to improve the capability of the DHI setup.
-
Effects of an acoustic wave in the positive column of a glow discharge.
… gas under dc conditions was measured using a magnetic probe in the form of a Rogowsky Ring. The electrodynamic speaker which generated the acoustic wave was calibrated in nitrogen gas in terms of acoustic pressure for frequencies from 50 Hz to 250 Hz at ambient pressures corresponding to glow …
-
The Reliability of Manual Ultrasonics in Detecting Internal Corrosion Within Carbon Steel Pipework
… set up to gather data on MUT using the standard probe and a novel developed magnetic probe coupler (MPC) the data gathered was statistically analysed to see if the MPC improved the reliability of the test The findings from this research could be implemented in a large-scale trial and introduced …
-
Investigation of the Three-Dimensional Structure of a Rotating Magnetic Field Driven Field-Reversed Configuration using Internal Magnetic Field Measurements
… Upgrade device (TCSU) used a rotating magnetic field (RMF) to form and sustain plasma in a field-reversed configuration (FRC). The physics of RMF current drive can be modeled in terms of the torque acting on the FRC. A fully translatable three-axis internal magnetic probe was built and …
-
EFFECT OF LITHIUM COATING ON THE IMPURITIES AND SHIELDING EFFECT OF PLASMA ON THE RESONANT MAGNETIC PERTURBATIONS FIELD IN THE STOR-M TOKAMAK PLASMA
… are in the visible range of the electromagnetic spectrum. They are CIII which is observable at 464.74 nm, CVI at 529.05 nm, and OV at 650.02 nm. Before the chamber was coated with lithium, the intensities of the impurity lines were measured and then compared to the intensities after the …
-
Studies in The Characterisation of Magnetic Force Microscope Probe
A magnetically coated tip is a fundamental part of the MFM instrument. These tips’ are bought commercially and/or individually manufactured in various shapes and sizes and with various material coatings and thicknesses. The sheer extent of possible combinations and the lack of a truly standard and …
-
Rayleigh—Taylor-Instability Evolution in Colliding-Plasma-Jet Experiments with Magnetic and Viscous Stabilization
… is influenced by the presence of viscosity and magnetic fields, both of which have the potential to stabilize short-wavelength modes. Very few experimental observations of Rayleigh—Taylor growth in plasmas with stabilizing mechanisms are reported in the literature, and those that are reported …
-
Electromagnetic Probe and Driving Circuit Design for Micro Magnetic Stimulation of Small Animal Brains
Magnetic stimulation is becoming more and more popular recently as a kind of medical treatment for brain function. By generating an alternating magnetic field from the electromagnetic probe, the induced electric field will be generated in a small region and stimulate a single or a group of …
-
The star thrust experiment, rotating magnetic field current drive in the field reversed configuration
… Reversed Configuration (FRC) with a Rotating Magnetic Field (RMF) operated at a strength of 25 G and a frequency of 350 kHz. The RMF was generated with two IGBT switched solid state power supplies capable of delivering 2 MW each. Plasmas were typically 2 m long by 0.2m in radius and consisted …
-
In situ characterization of dynamic structures of coatings
… development and final coating properties. A magnetic microrheometer for in situ measurement of local viscosity of coatings was designed since conventional bulk rheometry cannot be used to follow the temporal and spatial gradients of viscosity in drying or curing coatings. Micron-sized …
-
Characterization of Wafer Bonding Condition by Using Electrochemical Impedance Spectroscopy (EIS)
… Impedance Spectroscopy (EIS) with a ball-to-rod magnetic probe configuration. The study investigates the electrical behavior of different bonded interfaces for correlating impedance characteristics with bonding quality. The results demonstrate that EIS is capable of precisely detecting and …
-
Superfluid stiffness measurements in micron-scale two-dimensional superconductors
This thesis describes magnetic measurements of two-dimensional mesoscale superconductors. First, we use a local magnetic probe to directly measure the superfluid response of the tunable, gate-induced superconducting state in MoS<sub>2</sub>. Our measurements suggest that disorder strongly impacts …
-
High speed plasma flow about probes
… evaluation of the interaction between a uniform magnetic field and a compressible inviscid, electrically conducting ideal gas flow past a blunt body is presented. An experiment using a double diaphragm shock tube to produce a slug of gas with high electrical conductivity is performed to confirm …
-
Diagnostics and modelling of an inductively coupled RF low-pressure low-temperature plasma
… of devices [I-5]. A two-dimensional, electromagnetic, finite-element model has been set up to simulate the operation of the inductively coupled plasma using the external coil configuration used in the experimental work. Given fixed external RF coil current and voltage and the measured plasma …
-
Polarimeter for an Accelerated Spheromak
… Inc. Faraday rotation is a function of the local magnetic field and electron density. Therefore, the polarimeter has the potential to provide information on the internal magnetic field of the plasma. A typical spheromak is about 1m in length and is accelerated to speeds on the order of 100km/s. At …
-
SUPERCONDUCTING RADIO FREQUENCY MATERIALS SCIENCE THROUGH NEAR-FIELD MAGNETIC MICROSCOPY
… this requirement is presented. First, a scanning magnetic microwave microscopy technique was used to study SRF grade Nb samples. Using this novel microscope the existence of surface weak-links was confirmed through their local nonlinear response. Time-Dependent Ginzburg-Landau (TDGL) simulations …
Page 1 of 2