Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"magnetic samples"”

  1. Automatic Alignment Methods for VSM Using Magnetic Samples with Reduced Time and Higher Precision

    … Magnetometers (VSM) are used to measure the magnetic properties of ferro or ferrimagnetic materials. They have a wide range of users in both industry and in universities. Currently VSMs require a manual alignment for each sample loaded in the instrument. If the sample is not centered within …

    texas-state Repository record for Automatic Alignment Methods for VSM Using Magnetic Samples with Reduced Time and Higher Precision (opens in a new tab)

  2. Pose and power control of electrically conductive materials through induced eddy-current generation for low-Earth orbit applications

    Magnetic manipulation in robotics has established itself as a viable method for dexterous, non-contact manipulation of materials. Utilizing a tractable mathematical framework, magnetic fields and gradients are generated with the goal of applying forces and torques to magnetic samples. …

    colo-mines Repository record for Pose and power control of electrically conductive materials through induced eddy-current generation for low-Earth orbit applications (opens in a new tab)

  3. Two-level noise and stochastic resonance in individual permalloy nanoscale magnets

    … of a study on stochastic resonance in individual magnetic random telegraph oscillators. We have fabricated sub-micron magnetic samples, which have multiple stable magnetic states. We are able to observe random telegraph switching between magnetic states and tune the energetics by varying the …

    umn Repository record for Two-level noise and stochastic resonance in individual permalloy nanoscale magnets (opens in a new tab)

  4. Scanning magnetometry with single-spin sensors

    Magnetic imaging is an increasingly important tool for fundamental research and technology. The nitrogen-vacancy centre (NV) defect in diamond has emerged as a promising single-spin sensor which can detect not only magnetic fields but also electric fields and temperature. 2D mapping of magnetic …

    bristol Repository record for Scanning magnetometry with single-spin sensors (opens in a new tab)

  5. Modeling Shape Effects in Nano Magnetic Materials With Web Based Micromagnetics

    … on the geometry and shape effects on submicron magnetic material. A web based micromagnetics program is written to model the hysteresis loop of nano magnetic samples with arbitrary geometry shapes and multiple magnetic materials. Three material samples have been modeled with this program along …

    uno Repository record for Modeling Shape Effects in Nano Magnetic Materials With Web Based Micromagnetics (opens in a new tab)

  6. Magnetic Nanoparticles Based on Iron: Synthesis, Characterization, Design, and Application

    Magnetic nanoparticles are of great interest for a wide range of applications. This work has focused on three primary forms of iron based nanoparticles and combinations thereof: α-iron, iron oxide, and iron carbide or cementite. The synthesis of several core-shell particles including cementite-iron …

    vcu Repository record for Magnetic Nanoparticles Based on Iron: Synthesis, Characterization, Design, and Application (opens in a new tab)

  7. Microwave-Frequency Characterization of Spin Transfer and Individual Nanomagnets

    … currents can excite. Our devices consist of two magnetic films (2-40 nm) separated by a nonmagnetic spacer (5-10 nm Cu or 1.25 nm MgO), patterned into a "nanopillar" of elliptical cross-section ~100 nm in diameter. One magnetic layer (a thicker or exchange-biased "fixed" layer) polarizes electron …

    cornell Repository record for Microwave-Frequency Characterization of Spin Transfer and Individual Nanomagnets (opens in a new tab)

  8. Design and construction of a magnetic force microscope

    A magnetic force microscope (MFM) is a special type of scanning force microscope which measures the stray field above a ferromagnetic sample with the help of a ferromagnetic cantilever. The aim of this project was to design and build a MFM head and interface it with a commercial scanning probe …

    tamu Repository record for Design and construction of a magnetic force microscope (opens in a new tab)

  9. Optical studies of novel electronic materials

    … The KR instrument was also used to study control magnetic samples (CoFeB and nickel films). We also present a theory for KR including both the magneto-optical constant and the Pockel’s constant. The theory describes our experimental results very well. We have performed optical spin voltaic …

    purdue-thes Repository record for Optical studies of novel electronic materials (opens in a new tab)

  10. Magnetic properties of individual iron filled carbon nanotubes and their application as probes for magnetic force microscopy

    … that require a long-term stability. The magnetic properties of the enclosed nanowire are in part determined by its small size and elongated shape. Magnetic force microscopy (MFM) measurements show that the iron wire exhibits a single domain behavior. Due to the large shape anisotropy it …

    qucosa-diss Repository record for Magnetic properties of individual iron filled carbon nanotubes and their application as probes for magnetic force microscopy (opens in a new tab)

  11. The Study of Stray Magnetic Fields from Digital Recording Heads for Tape Applications

    The study of stray magnetic fields from magnetic recording heads for tape applications was undertaken using the Differential Phase Contrast (DPC) mode of Lorentz microscopy and Magnetic Force Microscopy (MFM). Electron Beam Tomography (EBT), at Glasgow was derived from the DPC technique and this …

    glasgow Repository record for The Study of Stray Magnetic Fields from Digital Recording Heads for Tape Applications (opens in a new tab)

  12. Advanced detection in Lorentz microscopy: pixelated detection in differential phase contrast scanning transmission electron microscopy

    … sensitivity to measurements of the integrated magnetic induction within thin samples. This was achieved by a novel approach to the data acquisition, where instead of a segmented (annular) detector, a pixelated detector was used to measure the deflection of the scanning transmission microscopy …

    glasgow Repository record for Advanced detection in Lorentz microscopy: pixelated detection in differential phase contrast scanning transmission electron microscopy (opens in a new tab)

  13. Magnetic Levitation of Polymeric Photo-thermal Microgrippers

    … and microfabrication. In this thesis, a magnetically levitated microgripper is presented for microhandling tasks. The use of magnetic levitation for positioning reveals the problems associated with modeling of complex surface forces and the use of jointed parts or wires. The power …

    waterloo Repository record for Magnetic Levitation of Polymeric Photo-thermal Microgrippers (opens in a new tab)

  14. Low Temperature Co-fired Ceramics Technology for Power Magnetics Integration

    … ceramics (LTCC) technology for power converter magnetics integration. Because magnetic samples must be fabricated with thick conductors for power applications, the conventional LTCC process is modified by cutting trenches in the LTCC tapes where conductive paste is filled to produce thick …

    vt Repository record for Low Temperature Co-fired Ceramics Technology for Power Magnetics Integration (opens in a new tab)

  15. Electron transport in ferromagnetic nanostructures

    … what happens within submicrometer scale samples is one of the goals of modern condensed matter physics. Electron transport phenomena drew a lot of attention over the past two decades or so, not only because quantum corrections to the classical transport theory, but also they allow us to …

    rice Repository record for Electron transport in ferromagnetic nanostructures (opens in a new tab)

  16. Non-Destructive Testing of metallic structures based on electromagnetic computational methods

    … between 2018 to 2021 and focuses on electromagnetic (EM) computational methods in the field of non-destructive testing (NDT).<br/><br/>Conductive samples affect the electromagnetic field generated by coils with alternating induced currents. Referring to eddy current effects, materials with …

    northampton Repository record for Non-Destructive Testing of metallic structures based on electromagnetic computational methods (opens in a new tab)

  17. Ανθρακοθερμική αναγωγή καθαρών οξειδίων μετάλλων και μεταλλευμάτων με τη χρήση μικροκυματικής ακτινοβολίας

    … and Mössbauer phasmatoscopy of the reduced samples, showed the quick reduction of hematite mainly to metallic iron (Fe-Ni) and secondarily to Fe+2 phases, such as spinel, fayalite and ferrosilite. The reduction degree of the laterite ore was examined as a function of the heating duration, …

    greece Repository record for Ανθρακοθερμική αναγωγή καθαρών οξειδίων μετάλλων και μεταλλευμάτων με τη χρήση μικροκυματικής ακτινοβολίας (opens in a new tab)

  18. Defect Induced Magnetism in Titanium Dioxide

    … the impurities concentration of the samples were examined using particle induced X-ray emission. The impurity concentration is too low to be the origin of the measured ferromagnetic signal after irradiation with low energetic ions. The as-grown samples show a small ferromagnetic …

    qucosa-diss Repository record for Defect Induced Magnetism in Titanium Dioxide (opens in a new tab)