Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"magnetic-bottle"”.

  1. Experimental and Theoretical Explorations of Anion Photoelectron Spectroscopy and Photoionization

    … (TOF) mass spectrometer coupled with a magnetic bottle photoelectron spectrometer (PES). The apparatus was fitted with an additional ion source, a novel electrostrpay ionization (ESI) source, leading to necessary modifications to the vacuum system, TOF spectrometer region, and the light …

    jhu Repository record for Experimental and Theoretical Explorations of Anion Photoelectron Spectroscopy and Photoionization (opens in a new tab)

  2. Charge Transfer to Solvent Dynamics in Iodide Aqueous Solution Studied at Ionization Threshold

    … and time-of-flight electron spectrometer of the magnetic bottle type. The spectrometer was designed to measure the energy spectra of electrons generated from liquids excited by a strong laser field as well as by photons in the range from ultra-violet to soft X-rays. Its energy resolution ΔE/E is …

    fu-berlin Repository record for Charge Transfer to Solvent Dynamics in Iodide Aqueous Solution Studied at Ionization Threshold (opens in a new tab)

  3. Construction of a high-resolution photoelectron spectrometer

    … a major improvement to the energy resolution of magnetic bottle time of flight photoelectron spectroscopy on free anions in the UV energy range.<br> MBTOF-PES, or MBPES, is a widely established method for studying free atomic, molecular and cluster ions. The main advantage of MBPES is its high …

    freiburg-diss Repository record for Construction of a high-resolution photoelectron spectrometer (opens in a new tab)

  4. Unbalanced magnetrons

    … system was constructed to measure the magnetic field pattern of the magnetrons, which allowed for a detailed analysis in terms of magnetic field lines. A multiple, plasma probe assembly was developed to measure the discharge characteristics for various unbalanced magnetron …

    ubc Repository record for Unbalanced magnetrons (opens in a new tab) Download PDF for Unbalanced magnetrons (opens in a new tab)

  5. Charakterisierung kleiner Aromaten-Cluster mit der excited state- Photoelektronenspektroskopie

    … Spektrometer wurde eine Kombination aus einem "magnetic bottle"-Photoelektronen- und einem linearen TOF-Massenspektrometer entwickelt. Es werden REMPI-Spektren, Photoelektronenausbeute- und excited state- Photoelektronenspektren von kleinen Clustern vorgestellt, die aus Aromaten (Toluol, Anisol) …

    fu-berlin Repository record for Charakterisierung kleiner Aromaten-Cluster mit der excited state- Photoelektronenspektroskopie (opens in a new tab)

  6. High-resolution photoelectron spectroscopy on cold metal clusters

    A new high-resolution type of magnetic bottle photoelectron spectrometer (MB-PES) has been tested at energies allowing for valence and shallow core electrons studies at the same time. The established laboratory setup with Doppler compensation and time-dependent electron deceleration was optimised …

    freiburg-diss Repository record for High-resolution photoelectron spectroscopy on cold metal clusters (opens in a new tab)

  7. Angular distributions of photoelectrons from cold, size-selected sodium cluster anions

    … agreement with the spectra measured earlier in a magnetic-bottle time-of-flight spectrometer, but the resolution is significantly enhanced due to the low cluster temperature. While essentially all transitions are parallel for 4.03 eV photon energy, a strong dependence of the angular distributions …

    freiburg-diss Repository record for Angular distributions of photoelectrons from cold, size-selected sodium cluster anions (opens in a new tab)

  8. Characterization of the Th-229 nuclear clock transition

    … continue their flight as neutral atoms through a magnetic-bottle type retardation electron spectrometer. The isomeric state decays in-flight and the kinetic energy of the emitted internal conversion electrons can be measured with the spectrometer. By a careful analysis and comparison with …

    lmu-germany Repository record for Characterization of the Th-229 nuclear clock transition (opens in a new tab)

  9. Time-resolved photoelectron spectroscopy of DNA molecules in solution

    In this thesis, I have advanced the recently-developed method of time-resolved liquid jet photoelectron spectroscopy to study the excited-state dynamics of solvated molecules applying femtosecond pulses in the ultraviolet range. The focus of this work was on the molecules that probably are the most …

    fu-berlin Repository record for Time-resolved photoelectron spectroscopy of DNA molecules in solution (opens in a new tab)