Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 8 of 8 for “"magnetostatic analysis"”.
-
Analysis and design of a conductively cooled superconducting magnet system for a rotary active magnetic regenerative liquefier
… This thesis presents a substantial part of the analysis and design of such a SC magnet system for an AMRL. Potential SC coil configurations for the magnet system of a rotary AMRL were examined and a partial tokamak and an elliptical split pair were selected as suitable configurations. The …
-
A phenomenological constitutive model for magnetic shape memory alloys
… loading cases and analyzed in detail. Finally, magnetostatic boundary value problems for MSMAs are considered and numerically solved using the finite element method. For these computations the developed constitutive model provides the nonlinear magnetic properties of the MSMA. The knowledge of …
-
Novel single-source surface integral equations for scattering on 2-D penetrable cylinders and current flow modeling in 2-D and 3-D conductors
… Electric Field Integral Equation (SVS-EFIE) for magnetostatic analysis of 2-D transmission lines and broadband resistance and inductance extraction in 3-D interconnects. Furthermore, the novel integral equation can be used for the solution of full-wave scattering problems on penetrable 2-D …
-
Ανάλυση απωλειών μετασχηματιστών ισχύος με προηγμένα υλικά
… iterative procedure and nonlinear finite element magnetostatic analysis, avoiding in this manner the computationally expensive harmonic and transient analysis. The representation of the wound core material anisotropy is accomplished by a new elliptic anisotropy model specifically developed for …
-
Design and Development of a Force Generator Based on Magnetorheological Fluid
… selected. The magnetic circuit was validated by magnetostatic analysis. The final design of the actuator prototype was developed based on experimental observations. The actuator produces an output force appropriate for bone biopsy (high range of forces). The hysteretic behavior of the proposed …
-
Design of sputtering system for hemispherical boron 10 target
… design was based on various electrostatic and magnetostatic analysis from TRICOMP 6.0 (Finite Element Software for Electromagnetics), SOLIDWORKS 2006 (3 D Mechanical Design Software) and previous experience with sputtering systems and vacuum systems. The vacuum chamber was evacuated by an …
-
Konstrukce nízkotlakého pístového reometru
Tato práce se zabývá konstrukcí nízkotlakého reometru určeného pro experimentální zjišťování vlastností magnetoreologické (MR) kapaliny při dlouhodobé zátěži. V první části práce je krátce MR kapalina představena. Dále je provedena rešerše týkající se způsobů měření vlastností kapalina a přehled MR …
-
Působení elektrodynamických sil v rozváděči nízkého napětí
Tato bakalářská práce se zabývá problematikou silových působení proudu v elektrických rozváděčích, která vznikají interakcí magnetických polí. Magnetická pole vznikají mezi vodiči, jimiž prochází elektrický proud. Rozváděče je nutné konstruovat se zřetelem na takto vzniklé síly, které zejména při …