Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 22 for “"magnitude-squared coherence"”
-
Investigation of Real-Time Magnitude Squared Coherence for Discrimination of Arrhythmias from Intracardiac Electrograms
… fibrillatory rhythms. Previous studies show that Magnitude-Squared Coherence (MSC) is a reliable algorithm for detecting fibrillation. However, use of MSC in an implantable device will require that it be performed in real-time and that it discriminates FIB from NON-FIB with better sensitivity and …
-
Detection of Atrial Fibrillation from the Surface Electrocardiogram Using Bivariate Analysis
… In this thesis research, we propose the use of magnitude-squared coherence as a method of detecting atrial fibrillation from the surface ECG. This study is the first to address the use of magnitude-squared coherence (MSC) for analysis of cardiac arrhythmias recorded from the surface …
-
Improvements to Ambient Audio Collection Systems for Smart City Applications
… The accuracy was validated by using magnitude-squared coherence. The Boll, Berouti, and Kamath spectral subtraction algorithms were applied to urban sound audio clips. This was shown to increase the accuracy and improve the Signal-to-Noise Ratio (SNR) by up to 20 dB when compared to …
-
Análise de sinais de EEG após reabilitação com imagética motora em indivíduos pós-AVC
… using the event-related potential (ERP), Magnitude-squared coherence (MSC), event-related desynchronism and synchronism (ERD/ERS) and Permutation Entropy during motor task. The parameters were compared in two rehabilitation moments: one week before MRI (PRM) and one month after MRI …
-
Avaliação da resposta cerebral a estímulo térmico não doloroso em regime permanente
… these stimuli, the signals were processed using Magnitude Squared Coherence (MSC). A synchronism between the hemispheres in the frontal and parietal regions during thermal stimulation was found in the delta band. Within hemispheres, the frontal, parietal and central regions also presented higher …
-
Road surface estimation: Exploring road surface estimation as a part of condition monitoring
… identify differences between the two surfaces. Magnitude squared coherence was used to determine the relation between the accelerometers. While the study suggests that road surface detection by the means of measuring acceleration seems achievable. The results need to be verified with larger sets …
-
An EEG feature selection toolbox for EEGLAB in the matlab environment
… are average power, correlation coefficient, magnitude squared coherence, and phase synchrony index. An exhaustive search is impractical in finding an optimal subset of features as the computational time increases exponentially with the number of desired features in the optimal subset. Three …
-
Two dimensional spatial coherence of skeletal muscle's natural vibrations during voluntary contractions.
… For a given pair of accelerometers, the spatial coherence of S-MMG is a measure of the similarity of the S-MMG signals propagating between those two sensors. Two common techniques to estimate the spatial coherence for narrowband S-MMG signals, namely the magnitude squared coherence function and …
-
Differentiating Epileptic from Psychogenic Nonepileptic EEG Signals using Time Frequency and Information Theoretic Measures of Connectivity
… between psychogenic and epileptic groups, magnitude squared coherence (MSC) and cross approximate entropy (C-ApEn) were used as measures of neural connectivity. MSC was computed within each neural frequency band (delta: 0.5Hz-4Hz, theta: 4-8Hz, alpha: 8-13Hz, beta: 13-30Hz, and gamma: …
-
Multimodal biomedical signal processing for corticomuscular coupling analysis
… assess corticomuscular coupling is the pair-wise magnitude-squared coherence (MSC). However, there are certain limitations associated with MSC, including the difficulty in robustly assessing group inference, only dealing with two types of data sets simultaneously and the biologically implausible …
-
The Effect of Low Frequencies on Seismic Data in Theory and a West Texas Case Study
… comparison of filter panels, and calculation of magnitude squared coherence using the raw data and comparison of frequency spectra, filter panels, and extracted wavelets in the processed data. The low-frequency geophone dataset did not yield as much coherent low-frequency content as anticipated, …
-
Analysis of Connectivity in EMG Signals to Examine Neural Correlations in Muscular Activation of Lower Leg Muscles for Postural Stability
… standing balance conditions was evaluated using magnitude squared coherence (MSC) and mutual information (MI). The leg muscles of interest were the tibialis anterior (TA), medial gastrocnemius (MG), and the soleus (S) of both legs. MSC is a linear measure of the phase relation between two signals …
-
Detection and Localization of Power and Coherence Dynamics with EEG
… as functional connectivity. Spectral power and coherence are often used to characterize such neural synchronization. Beta band oscillations have been reported to underlie the neural mechanism during repetitive auditory stimuli. Cortical generators of these underlying beta oscillations were …
-
Accelerometer Aided GNSS Spoofing Detection Using Wavelet Based Time-Frequency Analysis
… detection framework based on the wavelet cross-coherence between the IMU- and GNSS-derived acceleration signals is described. The continuous wavelet transform is computed independently on each signal, and the magnitude-squared coherence and cross-phase are evaluated in the time-frequency plane. …
-
Early Detection of Neurodegenerative Diseases from Bio-Signals: A Machine Learning Approach
… measurement techniques; phase synchrony, magnitude squared coherence and cross correlation are applied on three different databases of mild Alzheimer’s disease (MiAD) patients and healthy subjects. I have compared right and left temporal parts of brain with rest of the brain area (frontal, …
-
Evaluation of Low and High Frequency Dynamic Response for Condition Assessment of Reinforced Concrete Structures
… response (stress wave), was used in this method. Magnitude-squared coherence (MSC) was used to estimate the similarity between two recorded ultrasonic waveforms: a reference waveform under initial stress and one taken at a certain level of applied stress. Through a series of laboratory experiments …
-
Real-time adaptive noise cancellation for automatic speech recognition in a car environment : a thesis presented in partial fulfillment of the requirements for the degree of Doctor of Philosophy in Computer Engineering at Massey University, School of Engineering and Advanced Technology, Auckland, New Zealand
… which uses time-delay estimation together with magnitude-squared coherence (MSC). An experiment clearly shows the ability of the composite system to reduce noise outside of a defined active zone. In real-time environments a speech recognition system in a car has to receive the driver’s voice …
-
Differentiation of Ventricular Arrhythmias from a Single Transvenous Lead with Two Electrode Elements
… Previously, Rope Ila et al. [11] have shown magnitude-squared coherence (MSC), a frequency-domain measure of the constancy of phase relationship (time delay) between two bipolar electrograms, completely differentiates fibrillatory from nonfibrillatory rhythms. In these previous studies, MSC …
-
Multitaper Methods for Cyclostationary Feature Detection in Time Series Data: Application to ACE Interplanetary Magnetic Field Data
In this thesis, a deeper understanding of the theory of cyclostationary processes is sought. Conventional spectrum estimation techniques assume that the data is a realization of a stationary process. If the data is cyclostationary, standard methodology, which assumes stationarity and so …
-
Comparison between Bivariate and Contextual Analysis in the Detection of Atrial Fibrillation from Surface Electrocardiogram
… any computerized arrhythmia detection system. Magnitude-squared coherence (MSC), as applied to intracardiac data, has proven to be a reliable discriminator of fibrillatory and non-fibrillatory cardiac rhythms. In previous studies on surface ECG, techniques using percent power, RR variability …
Page 1 of 2