Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"main wind force resisting system"”.

  1. Inelastic Behavior of Three-Story Buildings with Concrete-Filled Composite Plate Shear Walls Subjected to Wind Loads

    Although elastic design of the main wind force resisting system in a building is the conventional approach it is not always desirable. In this study, nonlinear static and dynamic analyses are used to predict the inelastic behavior of a three-story building with concrete-filled composite plate shear …

    byu Repository record for Inelastic Behavior of Three-Story Buildings with Concrete-Filled Composite Plate Shear Walls Subjected to Wind Loads (opens in a new tab) Download PDF for Inelastic Behavior of Three-Story Buildings with Concrete-Filled Composite Plate Shear Walls Subjected to Wind Loads (opens in a new tab)

  2. Post-Charley Evaluation of Undamaged Homes in Punta Gorda Isles

    … practice. In the analysis, parameters such as wind velocity, exposure and building geometry were varied to assess the range of design forces. The maximum wind velocity was taken as 160 mph, based on findings reported in FEMA 488. Two idealized roof systems – a gable and hip – on a rectangular …

    usf Repository record for Post-Charley Evaluation of Undamaged Homes in Punta Gorda Isles (opens in a new tab)

  3. Development and assessment of ultra-high performance fibre-reinforced composite panels

    … is undesirable in flexural members and frame systems. This is minimised with the addition of steel fibres, resulting in the development of ultra-high performance fibre-reinforced concrete (UHPFRC). UHPFRC provides superior tensile strength and strain hardening properties, and the inclusion of …

    adelaide Repository record for Development and assessment of ultra-high performance fibre-reinforced composite panels (opens in a new tab)

  4. A Damage Assessment and Wind Loading Analysis of Residential Structures Built Post-1996 in Punta Gorda in the Wake of Hurricane Charley

    … approximately 20 damaged houses, damaged from wind loading only, an analysis of these houses (or types of houses) could then be undertaken complying with the most current building/wind codes used at the time of Charley’s landfall. Furthermore, by looking at the pictures, and using reports …

    usf Repository record for A Damage Assessment and Wind Loading Analysis of Residential Structures Built Post-1996 in Punta Gorda in the Wake of Hurricane Charley (opens in a new tab)

  5. Assessment of inelastic performance of wind-excited tall buildings with effects of biaxial interaction, degradation, P-Delta, and uncertainty

    … permit inelastic behavior under ultimate wind loadings. This linear design approach may potentially limit the use of more innovative tall building systems with improved performance and economy. The American Society of Civil Engineers (ASCE) has recently published pre-standard for …

    ttu Repository record for Assessment of inelastic performance of wind-excited tall buildings with effects of biaxial interaction, degradation, P-Delta, and uncertainty (opens in a new tab)

  6. Hailstone and freezer iceball mechanics and damage profiles

    … and adjusted the hail falling speed by the wind speed occurring during the hail event. ASTM E822-92 provide numerical methods for adjusting hail falling speed based upon the hail’s terminal velocity and wind speed. Many people have the experience of observing hail in the form of soft slush …

    ttu Repository record for Hailstone and freezer iceball mechanics and damage profiles (opens in a new tab)