Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 83 for “"manometric"”.
-
Manometric Studies of Earle's Strain L Sarcoma Cells
In his classic report, "Metabolism of Tumors" in 1925, Warburg postulated several generalizations concerning malignant tumor tissue metabolism, and summarized from his studies that "interference with the respiration in growing cells is, from the standpoint of the physiology of metabolism, the cause …
-
Fabrication of nanotube-based pressure microsensors for applications in manometric catheter diagnostics
The objective of this PhD research is to carry out experimental investigation to produce a flexible microsensor based on polymer and carbon nanotubes for pressure and strain measurements. This thesis will first give an overview of the micro‐electro‐mechanical‐systems (MEMS) technology, and the …
-
A Manometric Method for the Determination of Soil Carbonates in the Field
In soil survey work the method now generally used to evaluate the carbonate content of the soil in the field is to observe the amount of effervescence that takes place when the soil reacts with dilute acid. The four degrees of effervescence usually recognized are designated by the symbols eo, e, …
-
A Manometric Analysis of Metabolic Activity in the Developing Chick Yolk Sac
The advance of the avian yolk sac over the surface of the yolk sphere offers a system exhibiting an extremely rapid growth rate with subsequent sudden decrease in this rate. To attempt.to understand the factors controlling such a growth phenomena, one approach is an inspection of the changes in …
-
Manometric determination of the biochemical oxygen demand of sulfite paper mill wastes
… test procedure, but may be determined by manometric measurement of the free oxygen utilized. In either case, the B.O.D. determination requires at least 24 hours. Since the free oxygen involved in the B.O.D. of a waste is utilized in metabolic processes of various microorganisms present, an …
-
Bolus clearance ratio across timing of airway invasion and its relationship to manometric measures
… for self-administered liquid barium swallows. Manometric data were obtained from an existing database, from which five pressure metrics of the oropharynx and esophagus were extracted for analysis. A two-way ANOVA was used to compare bolus clearance across groups. There was a significant …
-
Application of the manometric technique to a study of the biochemical oxygen demand of a neutralized acid waste
The purpose of this investigation was to use the manometric method to determine the effect of the following variables on the B.O.D. values of a neutralized acid industrial waste: pH, type of seed, age of seed, adapted seed, dilution water, and dilution. In order to determine the effect of each …
-
Metabolic studies on ASPERGILLUS NIGER 72-4
… of organic phosphates in the mats and by manometric experiments. By using the Umbreit fractionation method combined with chromatographic analysis none of the phosphorylated intermediates present in the Embden-Meyerhof system could be identified. Evidence for a pentose and a ketose …
-
Optimization and development of techniques for the assessment of organic substrates stability
… oxygen consumption is determined either through manometric principles or using sensors placed in the headspace of the reactors) and dynamic ones (in which oxygen uptake and carbon dioxide generation are determined by measuring the difference between the inlet and the outlet of the reactor), …
-
Benign anorectal disorders
… Botulinum Toxin, were prospectively assessed for manometric and clinical outcome. A new treatment regime, inducible nitric oxide, was prospectively assessed in an animal model and a new manometric observation in anal fissure patients, the Fast Wave, was validated. Anal Incontinence: The magnitude …
-
Proximal gastric motor and sensory function in health and disease / by Geoffrey Stuart Hebbard.
… in determining gastric outflow, a high accuracy manometric recording system is developed ; patterns of intragastric pressure are then examined during gastric emptying of saline. Finally, a new barostat is designed and tested.
-
Ventricular oxygen consumption as influenced by myocardial fiber length and tension in the rat.
… were carried out in two different Warburg manometric systems. In a stationary manometric system, which permitted the simultaneous measurement of oxygen consumption, resting and developed tension, and also fiber length, the influence of both resting tension and fiber length was determined in …
-
The Effects of Selected Algicides and Some Coordination Complexes upon the Apparent Photosynthesis of Chlorella Pyrenoidosa
… the Warburg apparatus, or variations of this manometric technique, since Warburg's experiments (52, 53) where the effects of cyanides upon dark reactions and of urethanes upon light reactions of photosynthesis were demonstrated. The same basic techniques were utilized in this research in …
-
Morphological and Physiological Effects of 2,4-D on Gram-Negative and Gram-Positive Bacteria
Manometric, spectrophotometric, photomicrographic and quantitative biochemical techniques were employed to determine the morphological and physiological effects of 2,4-D on Gram-positive and Gram-negative bacteria. The growth and motility of Gram-positive bacteria appeared to be more adversely …
-
Pressure-Flow Kinetics in the Opossum Sphincter of Oddi
… analysis of SO kinetics had not been undertaken. Manometric study has shown that omnipresent peristaltic waves propagate cauded in the SO segment. This phenomenon makes analysis of the entire segment difficult. Previous experiments have also shown that a nozzle-shaped high-pressure zone exists in …
-
Radiation protection by biological pigments
… respiration and photosynthesis were observed by manometric methods. Tentative conclusions were that carotenoid pigments do not protect cells from inactivation by ultraviolet (protein-absorbed) radiation and that the observed effects do involve indirect action. Absorption spectra of the five types …
-
Some aspects of leucocyte metabolism: "in vitro" effects of drugs inducing agranulocytosis on separated human lymphocytes and polymorphonuclear leucocytes
… of the separated leucocytes was measured using manometric and enzymic methods respectively. It was found that drugs inducing predominately agranulocytosis - chlorpromazine, amidopyrine, and thiouracil - inhibited PMN respiration by 20% at concentrations which occur "in vivo" under normal …
-
Observations on some motility disturbances of the human distal bowel and pelvic floor
… chronic radiation anorectal injury: | 4.1 The manometric function of the internal anal sphincter is compromised with diminution in sphincter length, basal pressure and abnormalities of the rectosphincteric reflex. | 4.2 The external anal sphincter remains manoraetrically normal. Its mean motor …
Page 1 of 5