Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"marginal gap"”.

  1. Marginal gap and internal fit of CEREC e.max and Celtra Duo crowns

    Objectives: To compare marginal and internal fit as well as marginal chipping of e.max (EM) and Celtra Duo (CD) all-ceramic crowns fabricated using chairside economical restoration of esthetic ceramics (CEREC) system. Material and Methods: Tooth # 15 was prepared for an all-ceramic crown on an …

    ubc Repository record for Marginal gap and internal fit of CEREC e.max and Celtra Duo crowns (opens in a new tab) Download PDF for Marginal gap and internal fit of CEREC e.max and Celtra Duo crowns (opens in a new tab)

  2. Marginal Gap and Internal Fit of a Zirconia Crown and Implant Abutment using Three Different Digital Workflows

    … evaluated. The aim of this study was to evaluate marginal and internal adaptation of an implant abutment and crown using three digital workflows. The first workflow, the more traditional interrupted digital workflow which includes a re-scan of the final abutment, was compared to two full digital …

    tamu Repository record for Marginal Gap and Internal Fit of a Zirconia Crown and Implant Abutment using Three Different Digital Workflows (opens in a new tab)

  3. Evaluation of fracture resistance of three post and core systems in endodontically treated teeth under loading to failure; and marginal gap measurement before and after cyclic loading

    … teeth by loading to failure, and to measure marginal gaps before and after cyclic loading. Sixty extracted canines were assigned to three groups. The groups tested were: 1) Single cast post and core (Group CP). 2) Prefabricated metal post and composite resin core (Group MR). 3) Glass fiber …

    iupui Repository record for Evaluation of fracture resistance of three post and core systems in endodontically treated teeth under loading to failure; and marginal gap measurement before and after cyclic loading (opens in a new tab)

  4. Randspaltuntersuchung bei Procera® AllCeram-Kronen

    … mit dem PROCERA AllCeram-System. Welche marginale Passgenauigkeit läßt sich mit dem PROCERA AllCeram System in-vivo erreichen? (external marginal gap) Wie ist die Passung im Bereich des Zementspaltes zu beurteilen? (internal marginal gap) Welchen Einfluss hat die gewählte Präparationsform …

    fu-berlin Repository record for Randspaltuntersuchung bei Procera® AllCeram-Kronen (opens in a new tab)

  5. The effect of crown cementation on the marginal fit using a micro-CT measurement technique

    … To study the effect of cementation on the marginal gap of lithium disilicate (LDS) crowns made with digital impression and manufacturing (DD), digital impression and traditional pressed manufacturing (DP) and traditional impression and manufacturing (TP). Methods: Ivorine typodont tooth #15 …

    ubc Repository record for The effect of crown cementation on the marginal fit using a micro-CT measurement technique (opens in a new tab) Download PDF for The effect of crown cementation on the marginal fit using a micro-CT measurement technique (opens in a new tab)

  6. Comparison of marginal fit of lithium disilicate crowns fabricated with CAD-CAM technology using conventional impressions and two intra-oral digital scanners.

    … to conventional techniques. This study compared marginal gap size in crowns fabricated by conventional and digital impression methods. One typodont maxillary right central incisor was prepared for an all-ceramic crown. Ten impressions were made with each method: conventional using polyvinyl …

    louisville Repository record for Comparison of marginal fit of lithium disilicate crowns fabricated with CAD-CAM technology using conventional impressions and two intra-oral digital scanners. (opens in a new tab)

  7. SMART INTERSECTIONS: COOPERATIVE TRAFFIC CONTROL FOR LONGER BATTERY LIFE OF COMMUNICANT AUTONOMOUS VEHICLES

    … size, network speed, and the synchronization marginal gap length. These analytical results of the research indicate that the battery-capacity loss rate of CAVs is a strictly increasing function of the network speed, but a strictly decreasing function of both the platoon size and the marginal …

    kennesaw Repository record for SMART INTERSECTIONS: COOPERATIVE TRAFFIC CONTROL FOR LONGER BATTERY LIFE OF COMMUNICANT AUTONOMOUS VEHICLES (opens in a new tab)

  8. A comparison of crown marginal fit fabricated using digital and conventional methods

    … of this study was to determine and compare the marginal fit of crowns fabricated using digital and conventional methods. Materials and Methods. A maxillary right second bicuspid, set in a typodont (Frasaco, Greenville, N.C., USA), was prepared for a ceramic crown. The maxillary typodont was then …

    ubc Repository record for A comparison of crown marginal fit fabricated using digital and conventional methods (opens in a new tab) Download PDF for A comparison of crown marginal fit fabricated using digital and conventional methods (opens in a new tab)

  9. Marginal Adaptation of CAD/CAM Hybrid Ceramic Crowns Made on Preparations With and Without Surface Finishing

    … that preparation quality has an impact on marginal fit of milled restorations. However, as chair-side CAD/CAM technology improves, and newer systems and materials are released, it remains unclear if preparation quality still impacts marginal adaptation of milled restoration. Purpose: This …

    penn Repository record for Marginal Adaptation of CAD/CAM Hybrid Ceramic Crowns Made on Preparations With and Without Surface Finishing (opens in a new tab)

  10. In vitro comparison of marginal and internal fit of 3D printed definitive crowns and CAD CAM milled crowns

    Objective: To compare the marginal fit and internal adaptation of novel additively manufactured (3D printed) ceramic filled hybrid composite definitive crowns and milled monolithic zirconia milled crowns. Materials & Methods: A single die STL file was used to create a congruent base with 6 points …

    ubc Repository record for In vitro comparison of marginal and internal fit of 3D printed definitive crowns and CAD CAM milled crowns (opens in a new tab) Download PDF for In vitro comparison of marginal and internal fit of 3D printed definitive crowns and CAD CAM milled crowns (opens in a new tab)

  11. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: a systematic review and meta-analysis

    … of digital impression systems in terms of the marginal accuracy of ceramic restorations, whereas others show that the conventional method provides restorations with better marginal fit than fully digital fabrication. Which impression method provides the lowest mean values for marginal …

    greece Repository record for Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: a systematic review and meta-analysis (opens in a new tab)

  12. ANTIBACTERIAL EFFICACY OF CONTEMPORARY BIOACTIVE DENTAL RESTORATIVE MATERIALS AGAINST STREPTOCOCCUS MUTANS

    … Secondary caries develops when there is marginal gap formation, resulting in microleakage with bacterial invasion at the tooth-restoration interface. Bioactive glass dental restoratives were introduced to overcome this challenge. They work by forming calcium phosphate rich or apatite-like …

    nus Repository record for ANTIBACTERIAL EFFICACY OF CONTEMPORARY BIOACTIVE DENTAL RESTORATIVE MATERIALS AGAINST STREPTOCOCCUS MUTANS (opens in a new tab) Download file for ANTIBACTERIAL EFFICACY OF CONTEMPORARY BIOACTIVE DENTAL RESTORATIVE MATERIALS AGAINST STREPTOCOCCUS MUTANS (opens in a new tab)

  13. Evaluating 3D fit of lithium disilicate restorations with a novel virtual measuring technique

    … of conventional cutbacks of 1.5mm with applied marginal wax. All patterns were pressed into lithium disilicate crowns, then fine polished and scanned. Each file was imported into a quality control metrology software (Geomagic Control X, 3D Systems) for marginal fit and internal fit evaluation …

    bu Repository record for Evaluating 3D fit of lithium disilicate restorations with a novel virtual measuring technique (opens in a new tab)

  14. Evaluating the marginal integrity of lithium disilicate veneers fabricated by digital impressions and CAD/CAM compared to conventional techniques.

    This in vitro study compared marginal gap size in anterior lithium disilicate veneers produced by conventional and digital impressions. One typodont right central incisor was prepared for an all-ceramic cast. Ten conventional veneers were fabricated using Type IV stone, PVS, and IPS e.max press, …

    louisville Repository record for Evaluating the marginal integrity of lithium disilicate veneers fabricated by digital impressions and CAD/CAM compared to conventional techniques. (opens in a new tab)

  15. A comparison of a proprietary and generic dental implant abutment connection using computerised microtomography (micro-CT)

    … to be closely adapting, with no evidence of marginal gap horizontally or vertically. The unique Neoss implant-abutment connection contacts in half as many places as the generic implant-abutment connection. Generic implant abutment connections displayed marginal discrepancies in all seven …

    adelaide Repository record for A comparison of a proprietary and generic dental implant abutment connection using computerised microtomography (micro-CT) (opens in a new tab)

  16. Untersuchung des Randspaltes und der Löslichkeit von Befestigungskunststoffen bei Zementierung vollkeramischer Restaurationen mittels Microcomputertomographie

    … Der Randspalt wurde mit der Messung des marginalen Randspaltes und der marginalen Diskrepanz bewertet. Ergebnisse: Panavia F2.0 zeigte vor und nach Kausimulation die beste Werte für marginale Randspalt (118µm bzw. 124µm) und Marginale Diskrepanz (145 bzw. 154µm), folgt von Unicem …

    fu-berlin Repository record for Untersuchung des Randspaltes und der Löslichkeit von Befestigungskunststoffen bei Zementierung vollkeramischer Restaurationen mittels Microcomputertomographie (opens in a new tab)

  17. Flexural strength and marginal fit of two types of lithium disilicate ceramics for crowns

    … of 5 ceramic dental materials and to compare the marginal fit of crowns made with e.max press and a new experimental (EXP) press ceramic. MATERIALS AND METHODS: The materials tested for flexural strength included: E.max press, E.maxCAD, ENAMIC, Experimental press, and Experimental-CAD. Each group …

    bu Repository record for Flexural strength and marginal fit of two types of lithium disilicate ceramics for crowns (opens in a new tab)

  18. Effect of the adhesive strategy on clinical performance and marginal integrity of a universal adhesive in non-carious cervical lesions in a randomized 36-month study

    … evaluated both clinically and by quantitative marginal analysis (QMA) over 36 months. In 50 patients, three (n = 21) or four (n = 29) non-carious cervical lesions (NCCL) were restored with Venus® Diamond Flow (Kulzer GmbH, Hanau, Germany).The adhesive iBond® Universal (iBU, Kulzer, Germany) was …

    qucosa-diss

  19. Marginal fit of lithium disilicate crowns : a three-dimensional analysis

    Objectives: To compare the marginal fit of lithium disilicate (LDS) crowns fabricated with digital impression and manufacturing (termed “DD”), digital impression and traditional pressed manufacturing (termed “DP”), and traditional impression and manufacturing (termed “TP”). Methods: Tooth #15 was …

    ubc Repository record for Marginal fit of lithium disilicate crowns : a three-dimensional analysis (opens in a new tab) Download PDF for Marginal fit of lithium disilicate crowns : a three-dimensional analysis (opens in a new tab)

  20. Μελέτη της προσαρμογής του υλικού στα τοιχώματα της κοιλότητας σε εμφράξεις σύνθετης ρητίνης - υαλοϊονομερούς κονίας

    … glass ionomer composite resin restoration on gap width in regard to the shape of GI, b) the interaction between acid etching and combined GI/CR restoration on gap along the cavity walls.Cavities were prepared at the buccal and lingual surfaces of extracted human premolar teeth. They were …

    greece Repository record for Μελέτη της προσαρμογής του υλικού στα τοιχώματα της κοιλότητας σε εμφράξεις σύνθετης ρητίνης - υαλοϊονομερούς κονίας (opens in a new tab)

Page 1 of 2