Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 38 for “"material budget"”

  1. Bent monolithic active pixel sensors and material budget imaging studies towards the ALICE ITS3 upgrade

    … sensors used in the ITS2 detector, and the material budget associated with carbon foam support structures for future wafer-scale sensors in the ITS3. Through a series of extensive test beam campaigns, it was demonstrated that ALPIDE sensors retain their full functionality and performance …

    heid-diss Repository record for Bent monolithic active pixel sensors and material budget imaging studies towards the ALICE ITS3 upgrade (opens in a new tab)

  2. Prospect studies for Higgs Boson pair production to bbyy final state at the HL-LHC with the ATLAS detector

    … more realistic estimate of the expected material budget of the ITk, as well as dedicated functions for both the 50$\times$50$\mu$m$^2$ and 25$\times$100$\mu$m$^2$ pixel sensor geometries. A Boosted Decision Tree method was applied to the $H \rightarrow HH \rightarrow b\bar{b}\gamma\gamma$ …

    birmingham Repository record for Prospect studies for Higgs Boson pair production to bbyy final state at the HL-LHC with the ATLAS detector (opens in a new tab)

  3. Front-End Circuits for Radiation-Hard Monolithic CMOS Sensors targeting High-Energy Physics Applications

    … an easier detector assembly, lower cost, lower material budget and lower power consumption. This work has been carried out in the EP-R&D program at CERN and its main goal is the development of analog readout solutions for monolithic sensors able to cope with the requirements of future …

    epfl Repository record for Front-End Circuits for Radiation-Hard Monolithic CMOS Sensors targeting High-Energy Physics Applications (opens in a new tab)

  4. Development of floating strip micromegas detectors

    … A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20\,MeV protons at particle rates of 550\,kHz is possible. The reconstruction …

    lmu-germany Repository record for Development of floating strip micromegas detectors (opens in a new tab)

  5. Straggling in Underdepleted Ultra-Thin Silicon HV-CMOS Sensors

    … resolution, radiation hardness, and minimal material budget. However, a lower material budget necessitates thinner detectors, which provide less active volume for energy deposition, thereby reducing the signal-to-noise ratio. A promising approach is represented by HV-MAPS (High-Voltage …

    heid-diss Repository record for Straggling in Underdepleted Ultra-Thin Silicon HV-CMOS Sensors (opens in a new tab)

  6. Studies On Monolithic Active Pixel Sensors and Detector Performance for the Inner Tracking System Upgrade of ALICE

    … with high granularity which would cater to the material budget, readout and radiation hardness requirements for the upgrade. The geometry is optimized for high efficiency, both in standalone tracking and ITS-TPC combined tracking. TowerJazz 0.18 μm technology is selected for designing the pixels …

    cagliari Repository record for Studies On Monolithic Active Pixel Sensors and Detector Performance for the Inner Tracking System Upgrade of ALICE (opens in a new tab)

  7. Pixel Sensor Evaluation and Track Fitting for the Mu3e Experiment

    … spectrometer with a pixel detector. A low material budget and special algorithms are required to reconstruct the low momentum, strongly curved tracks with high precision at high rates. In this work, I present the first systematic performance evaluation of the Mu3e high voltage monolithic …

    heid-diss Repository record for Pixel Sensor Evaluation and Track Fitting for the Mu3e Experiment (opens in a new tab)

  8. Studies of CP violation in the Bs →J/ψϕ channel, and prospects for future measurements at the ATLAS detector

    … B0s meson background. A separate study into the material budget at ATLAS, including consideration of the material map variation systematics is also presented.

    lancaster Repository record for Studies of CP violation in the Bs →J/ψϕ channel, and prospects for future measurements at the ATLAS detector (opens in a new tab)

  9. Research and development of silicon strip detectors in CMOS- and 3D-technology, and construction and characterisation of detector modules for the Phase-II upgrade of the ATLAS experiments

    … silicon tracking detectors. For FCC-ee, a low material budget and excellent spatial resolution are essential. Whereas in the hadron-collider scenario of FCC-hh, detectors must withstand extreme radiation environments with fluences up to 1⋅10^17 n_eq/cm^2, while maintaining both spatial and time …

    freiburg-diss Repository record for Research and development of silicon strip detectors in CMOS- and 3D-technology, and construction and characterisation of detector modules for the Phase-II upgrade of the ATLAS experiments (opens in a new tab)

  10. Development of a Waveform Sampling Asic with Femtosecond Timing for a Low Occupancy Vertex Detector.

    … of the vertex detectors using existing low material budget techniques. Consequently, new approaches are being studied that meet the vertexing requirements while lowering the occupancy and the data rate. In this work we introduce the architecture and speci cations for a novel vertex detector …

    hawaii Repository record for Development of a Waveform Sampling Asic with Femtosecond Timing for a Low Occupancy Vertex Detector. (opens in a new tab)

  11. Development of a 3D Silicon Coincidence Avalanche Detector (3D-SiCAD) for charged particle tracking

    … de résistance aux rayonnements ionisants, "material budget", vitesse, bruit et résolution spatiale. Dans ce travail, un prototype a été conçu et fabriqué en technologie HV-CMOS 0,35µm, en utilisant un assemblage 3D de type "flip-chip" avec pour finalité de démontrer la faisabilité d’un tel …

    star-france Repository record for Development of a 3D Silicon Coincidence Avalanche Detector (3D-SiCAD) for charged particle tracking (opens in a new tab)

  12. Simulation Studies for Measuring the Soft-Photon Spectrum with the ALICE 3 Forward Conversion Tracker

    … of the beam pipe is suggested to reduce the material budget in front of the FCT and as such the kinematic regime where the significance exceeds 5 is extended to 0.5 < kT < 10 MeV/c for the case where the excess is 4 times the predicted internal bremsstrahlung spectrum. In this thesis the …

    heid-diss Repository record for Simulation Studies for Measuring the Soft-Photon Spectrum with the ALICE 3 Forward Conversion Tracker (opens in a new tab)

  13. A High Rate Testbeam Data Acquisition System and Characterization of High Voltage Monolithic Active Pixel Sensors

    … of the decay particles. Requirements on rate and material budget cannot be fulfilled by classical pixel sensors and demand the development of a novel pixel technology: high-voltage monolithic active pixel sensors (HV-MAPS). Two important steps towards a final pixel detector are discussed within …

    heid-diss Repository record for A High Rate Testbeam Data Acquisition System and Characterization of High Voltage Monolithic Active Pixel Sensors (opens in a new tab)

  14. Forward track reconstruction and quality assessment for the ALICE experiment of the Large Hadron Collider

    … experiment parameters of sensor resolution and material budget are also addressed in the reconstruction assessment. Results presented here justify the track-reconstruction strategy adopted by MFT for RUN 3. The developed algorithms used in this work were uploaded in ALICE online-offline …

    brazil-ufrgs Repository record for Forward track reconstruction and quality assessment for the ALICE experiment of the Large Hadron Collider (opens in a new tab)

  15. Construction, Commissioning and Performance Measurements of the Inner Tracking System Upgrade (ITS2) of ALICE at the LHC

    … inner-most layer by 16 mm, the reduction of the material budget and the decrease of the pixel pitch. Over the last few years, the upgraded ITS, ITS2, was successfully constructed at several international sites before being assembled into the concentric barrel structure of the final tracker at …

    liverpool Repository record for Construction, Commissioning and Performance Measurements of the Inner Tracking System Upgrade (ITS2) of ALICE at the LHC (opens in a new tab)

  16. Reconstruction of Photon Conversions using the ALICE Transition Radiation Detector

    … Radiation Detector (TRD). Because of the material budget in front and within the TRD, many conversions take place in its vicinity. To reconstruct these conversions, a stand-alone track reconstruction was implemented. The photon reconstruction was also made possible by a newly developed …

    heid-diss Repository record for Reconstruction of Photon Conversions using the ALICE Transition Radiation Detector (opens in a new tab)

  17. Accurate Profile Measurement of the low Intensity Secondary Beams in the CERN Experimental Areas

    … has the potential to perform better in terms of material budget, range of intensities measured, and active area size. In addition, it has particle counting capabilities, which could extend its application to momentum spectrometry or Time-of-Flight (ToF) measurements. Its resistance to radiation …

    epfl Repository record for Accurate Profile Measurement of the low Intensity Secondary Beams in the CERN Experimental Areas (opens in a new tab)

  18. Detection, quantification and 3D localization of anatomical changes with a helium-beam radiography system based on thin pixelated detectors

    … prototypes require devices with a large material budget. In order to increase the practicability and foster clinical acceptance, a compact detection system was built from thin silicon pixel detectors. However, the system’s ability to precisely measure the clinically relevant quantity for …

    heid-diss Repository record for Detection, quantification and 3D localization of anatomical changes with a helium-beam radiography system based on thin pixelated detectors (opens in a new tab)

  19. Wafer-Scale Stitched CMOS Pixel Sensors: Characterisation and Detector Performance Studies for ALICE ITS3

    … This configuration achieves an unprecedented material budget of just X/X<sub>0</sub> ≃ 0.09% per layer. This material reduction, combined with a decrease in the distance of the innermost tracking layer from the interaction point, results in a factor-of-two improvement in pointing resolution at …

    oxford Repository record for Wafer-Scale Stitched CMOS Pixel Sensors: Characterisation and Detector Performance Studies for ALICE ITS3 (opens in a new tab)

  20. Application of avalanche detectors in scientific and industrial measurement systems

    … with high granularity and position accuracy, low material budget and power consumption. Both Hybrid and monolithic detectors have been proposed as particle trackers. Hybrid detectors have the advantage of allowing an independent customization of sensors and readout electronics, but they exhibit a …

    trento Repository record for Application of avalanche detectors in scientific and industrial measurement systems (opens in a new tab)

Page 1 of 2