Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"maximum torque per ampere"”.

  1. Simplified Maximum Torque per Ampere Trajectory Tracking for Permanent Magnet Synchronous Machine Drives

    The permanent magnet synchronous machine is considered one of the significant electric machines used in different applications due to its high torque density, high power density, high efficiency, and low maintenance. Due to the PM synchronous machines' design, the control system can drive the motor …

    carleton Repository record for Simplified Maximum Torque per Ampere Trajectory Tracking for Permanent Magnet Synchronous Machine Drives (opens in a new tab)

  2. Speed Control of Permanent Magnet Synchronous Motor Employing Direct Voltage Maximum Torque Per Ampere

    Permanent magnet synchronous motors (PMSMs) have become more attractive and competitive for various industrial applications. In the constant torque region, a commonly adopted technique for maximum torque utilization of PMSMs is known as maximum torque per ampere control (MTPA). This technique aims …

    carleton Repository record for Speed Control of Permanent Magnet Synchronous Motor Employing Direct Voltage Maximum Torque Per Ampere (opens in a new tab)

  3. Maximum torque per Ampere and maximum torque per Voltage operation of brushless DC motor drive systems with extended switching schemes

    … due to their simplicity, low cost, and good torque-speed characteristics. The conventional commutation methods include the 120-degree and 180-degree switching logics. For these commutation methods, the maximum torque per Ampere (MTPA) and maximum torque per Voltage (MTPV) control schemes are …

    ubc Repository record for Maximum torque per Ampere and maximum torque per Voltage operation of brushless DC motor drive systems with extended switching schemes (opens in a new tab) Download PDF for Maximum torque per Ampere and maximum torque per Voltage operation of brushless DC motor drive systems with extended switching schemes (opens in a new tab)

  4. Phase advance modulation of low-cost power electronic converters for SPM wind turbine generators.

    … applications. The system utilizes a surface permanent magnet (SPM) generator operating with a semi-bridge switched-mode rectifier (SMR) into a DC voltage load. Conventional control of a semi-bridge SMR results in lower output power than an inverter (i.e. fully-controlled voltage source …

    adelaide Repository record for Phase advance modulation of low-cost power electronic converters for SPM wind turbine generators. (opens in a new tab)

  5. Performance analysis and operating limits of dual inverter open winding IPMSM drives

    Operating capabilities of a dual inverter Open Winding Interior Permanent Magnet Synchronous Motor drive are investigated and compared with those of a conventional single inverter drive in Maximum Torque per Ampere and Field Weakening regions. To predict the performance and operating limits of the …

    manitoba Repository record for Performance analysis and operating limits of dual inverter open winding IPMSM drives (opens in a new tab)

  6. Efficiency Optimization and Control of Permanent Magnet Synchronous Brushless Motors in Three-Phase Pulse Width Modulated Voltage Source Inverter Drives

    In high performance drives where it is desirable to exploit the usefulness of reluctance torque and machine saliency, permanent magnet synchronous brushless motors are machines of choice. However, speed control of these machines especially in the flux weakening region becomes more complex due to …

    wvu Repository record for Efficiency Optimization and Control of Permanent Magnet Synchronous Brushless Motors in Three-Phase Pulse Width Modulated Voltage Source Inverter Drives (opens in a new tab)

  7. Comparing numerical and machine learning algorithms for optimized operation points of an electrical machine

    … (RL) based methods, for finding the optimal operating point of an Interior Permanent Magnet Synchronous Machine. Commonly, numerical methods are used to search for Maximum Torque Per Ampere (MTPA) points, which, although relatively accurate, often require significant computation time and …

    chalmers Repository record for Comparing numerical and machine learning algorithms for optimized operation points of an electrical machine (opens in a new tab)

  8. Torque -Angle Based Analysis and Control of Induction Machines

    Volts per hertz control, field-oriented control (FOC), and direct-torque control are the most popular induction motor control methods. One common feature that is shared by these control methods is to regulate the amplitude of the flux in the induction motor. There are numerous techniques to improve …

    uiuc Repository record for Torque -Angle Based Analysis and Control of Induction Machines (opens in a new tab)

  9. Development and evaluation of a novel neural network of PMSM for electric vehicle

    … for a surface-mounted and an interior-mounted permanent magnet synchronous machine (SPMSM and IPMSM). The ANN was trained by using Levenberg-Marquardt and forward accumulation through time algorithm. First, the thesis examines the fundamentals of motor parameters and two aforementioned vector …

    alabama Repository record for Development and evaluation of a novel neural network of PMSM for electric vehicle (opens in a new tab)

  10. Vektorové řízení pětifázového synchronního motoru s permanentními magnety

    … řízení pětifázového synchronního motoru s permanentními magnety umístěnými uvnitř rotoru (IPMSM). Pětifázové motory oproti třífázovým dosahují vyšší hustoty točivého momentu, plynulej- šího průběhu a větší odolnosti vůči poruchám. Pro jejich popis je představena rozšířená Clarkova a Parkova …

    brno-tech Repository record for Vektorové řízení pětifázového synchronního motoru s permanentními magnety (opens in a new tab)

  11. Enhanced Control Algorithms in Permanent Magnet Synchronous Machines

    Permanent magnet synchronous machines (PMSMs) are gaining increasing popularity in various applications due to their advantages, such as high efficiency, high power density, and superior control performance. A well-designed machine control algorithm is indispensable for a PMSM system to secure its …

    nebraska Repository record for Enhanced Control Algorithms in Permanent Magnet Synchronous Machines (opens in a new tab)

  12. Efficiency Optimization of Electric Drives with Variable Switching Frequency using Wide-Bandgap Motor Drives

    … pulse-width modulation (SPWM) over selected operating conditions. Utilizing ANSYS software tools, a drive system model containing an interior permanent magnet synchronous machine (IPMSM), a 3-phase inverter circuit, and a control system are developed. A preliminary study is carried out to …

    chalmers Repository record for Efficiency Optimization of Electric Drives with Variable Switching Frequency using Wide-Bandgap Motor Drives (opens in a new tab)

  13. Torque ripple reduction control of brushless DC motor drive systems with extended switching schemes

    … the Hall signals and naturally approximates the maximum torque per Ampere (MTPA) operation, achieving higher efficiency. The 180º commutation is preferred in applications requiring higher DC voltage utilization. The common drawback of the 120º and 180º commutated BLDC motors is the presence of a …

    ubc Repository record for Torque ripple reduction control of brushless DC motor drive systems with extended switching schemes (opens in a new tab) Download PDF for Torque ripple reduction control of brushless DC motor drive systems with extended switching schemes (opens in a new tab)

  14. Design and Control of Parallel Three-Phase AC Motor Drives in Battery-Electric Heavy-Haul Freight Locomotives

    … Due to climate change, many companies operating within the transportation sector are seeking to reduce their emissions, including Ontario Northland Rail (ONR), who operate afreight rail network in northern Ontario. ONR currently relies on diesel powered locomotives for their freight rail …

    queens Repository record for Design and Control of Parallel Three-Phase AC Motor Drives in Battery-Electric Heavy-Haul Freight Locomotives (opens in a new tab)

  15. Thermal Management of Power Electronic Converters in Electric Motor Drives Using Active Thermal Control and Active Cooling

    … controllability and flexibility. Additionally, Permanent Magnet Synchronous Machines (PMSMs) are favored in EVs for their higher torque, efficiency, performance, and heat dissipation capabilities compared to asynchronous machines. The reliable operation of power converters in PMSM drives is …

    clemson Repository record for Thermal Management of Power Electronic Converters in Electric Motor Drives Using Active Thermal Control and Active Cooling (opens in a new tab)

  16. Control Methods for Permanent-Magnet Synchronous Reluctance Motor Drives

    … as the synchronous reluctance motors, interior permanent-magnet synchronous motors, and permanent-magnet synchronous reluctance motors. An exact hold-equivalent discrete-time motor model is developed. The motor model is then used in the design and analysis of current controllers and flux …

    aalto Repository record for Control Methods for Permanent-Magnet Synchronous Reluctance Motor Drives (opens in a new tab)

  17. Ελαχιστοποίηση απωλειών σύγχρονων κινητήρων με δρομέα έκτυπων πόλων

    … pole, SMD in particular, consist of the copper losses, the iron losses and the stray losses. From the theoretical analysis and experimental verification, two loss minimization conditions are derived for the optimal values of the field current and the direct axis armature current, …

    greece Repository record for Ελαχιστοποίηση απωλειών σύγχρονων κινητήρων με δρομέα έκτυπων πόλων (opens in a new tab)

  18. Differential Geometric Control of Three-phase Solar Microinverters based on Lie Groups

    … the control scheme to maintain robust transient performance during disturbances. The control architecture of the inverter stage is typically implemented either in the abc frame, the stationary αβ frame, or the synchronous dq frame. Although these conventional approaches provide good steady-state …

    queens Repository record for Differential Geometric Control of Three-phase Solar Microinverters based on Lie Groups (opens in a new tab)

Page 1 of 2