Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 115 for “"mdct"”

  1. Simulation and Modeling for UHR-MDCT and Photon-Counting CT

    … as ultra-high resolution multi-detector CT (UHR-MDCT), and photon-counting CT, open the potential for visualizing bone microarchitecture and enables material decomposition with a single scan. UHR-MDCT comes with many challenges – image quality varies with the position of the object in the …

    jhu Repository record for Simulation and Modeling for UHR-MDCT and Photon-Counting CT (opens in a new tab)

  2. Comparison of MDCT with CBCT : Analysis of metallic artifact and attenuation value

    osaka

  3. Assessment of coronary artery plaque progression using 64 slice multi-detector computed tomography (MDCT)

    … were emphasized for many years. Coronary MDCT is non-invasive technique, and enable to detect of non-calcified atherosclerotic plaque and assess the plaque composition. Also coronary MDCT is an effective tool for assessment of serial change in plaque volume and then it would be used as a …

    ajou Repository record for Assessment of coronary artery plaque progression using 64 slice multi-detector computed tomography (MDCT) (opens in a new tab) Embargoed until 9999-12-31

  4. Automatic 3D extraction of pleural plaques and diffuse pleural thickening from lung MDCT images

    … from multi detector computed tomography (MDCT) images has been developed and tested. The algorithm for detecting diaphragmatic pleura includes estimation of the diaphragm top surface in 3D and identifying those voxels at a certain vertical distance from the estimated diaphragm, and with …

    unsw Repository record for Automatic 3D extraction of pleural plaques and diffuse pleural thickening from lung MDCT images (opens in a new tab)

  5. A Retrospective Study of MDCT Chest Examinations with Two Different Doses of IV Contrast Media

    … for which two contrast-enhanced routine MDCT chest scans were performed, using two different doses of iodinated water soluble IV contrast media.Methods: This was a retrospective study of an existing image database to compare image quality of two routine contrast-enhanced MDCT chest scans, …

    ohiolink Repository record for A Retrospective Study of MDCT Chest Examinations with Two Different Doses of IV Contrast Media (opens in a new tab)

  6. Accuracy of multidetector-row CT for restaging after neoadjuvant treatment in patients with oesophageal cancer

    … the diagnostic accuracy of 64-multidetector CT (MDCT) for restaging of patients with oesophageal cancer undergoing neoadjuvant therapy. METHODS: Results of pathological staging were correlated with those from 64-MDCT before and after neoadjuvant treatment in 35 patients using the American Joint …

    zurich Repository record for Accuracy of multidetector-row CT for restaging after neoadjuvant treatment in patients with oesophageal cancer (opens in a new tab)

  7. Hepatobiliary diseases in small animals: a comparison of ultrasonography and multidetector-row computed tomography

    … multidetector- row helical computed tomography (MDCT), with its superior spatial and temporal resolution, has resulted in improved detection and characterization of diffuse and focal liver lesions. The increased availability of MDCT in veterinary practice provides incentive to develop MDCT …

    bologna Repository record for Hepatobiliary diseases in small animals: a comparison of ultrasonography and multidetector-row computed tomography (opens in a new tab) Restricted access

  8. Pulmonary embolism and right ventricular function cardiac CT : right ventricular function in pulmonary embolism

    … multidetector-row computed tomography (MDCT). We demonstrated that RV and LV function can be accurately measured by using ECG-synchronized MDCT. Contrary to non-ECG synchronized MDCT-measured RV function, ECG-synchronized technique is a more accurate reflection of the hemodynamic …

    leiden Repository record for Pulmonary embolism and right ventricular function cardiac CT : right ventricular function in pulmonary embolism (opens in a new tab)

  9. Usefulness of Multidetector Computed Tomography Angiography in Vertebral and Basilar Artery Dissection

    … However, Multi-detector computed tomography (MDCT)angiography is not only a less invasive diagnostic technique than conventional angiography but also provides high quality images. We assessed clinical manifestations and usefulness of MDCT angiography in VBAD. METHODS: We retrospectively …

    ajou Repository record for Usefulness of Multidetector Computed Tomography Angiography in Vertebral and Basilar Artery Dissection (opens in a new tab) Embargoed until 9999-12-31

  10. Identification of Mg2+/Ca2+-sensing system in mouse distal convoluted tubule cells and characterization of its role in hormone-stimulated magnesium transport

    … mouse distal convoluted tubule cells (MDCT) retain a number of the properties ofin vivo distal convoluted tubule cells. This study was performed to identify polyvalent-cation sensing mechanisms in MDCT cells and to describe the co-ordinated response to hormones that control magnesium …

    ubc Repository record for Identification of Mg2+/Ca2+-sensing system in mouse distal convoluted tubule cells and characterization of its role in hormone-stimulated magnesium transport (opens in a new tab)

  11. Imaging of the Canine Heart Using Non ECG-Gated and ECG-Gated 64 Multidetector Computed Tomography

    ECG-gated multidetector computed tomography (MDCT) is an imaging modality widely utilized for the evaluation of cardiac pathology by physicians. However, there has been little research of cardiac MDCT imaging in veterinary patients. Presently, ECG-gating is an upgrade for MDCT, which few veterinary …

    vt Repository record for Imaging of the Canine Heart Using Non ECG-Gated and ECG-Gated 64 Multidetector Computed Tomography (opens in a new tab)

  12. Diagnostische Genauigkeit der primären Multidetektor-Ganzkörper- Computertomographie zur Erkennung und zum Ausschluss von Verletzungen des Hirn- und Gesichtsschädels sowie der Hals-Nacken-Region

    … (multidetector-row CT, MDCT) bei Schwerverletzten hat sich in den Industrienationen als primäres diagnostisches Instrument etabliert. Vor dem Hintergrund der Strahlenexposition ist ihr Nutzen-Risiko-Verhältnis insbesondere zur Abklärung der Gesichts- und Hals-/ …

    fu-berlin Repository record for Diagnostische Genauigkeit der primären Multidetektor-Ganzkörper- Computertomographie zur Erkennung und zum Ausschluss von Verletzungen des Hirn- und Gesichtsschädels sowie der Hals-Nacken-Region (opens in a new tab)

  13. Ανίχνευση ασβέστωσης των στεφανιαίων αρτηριών με ψηφιακή ακτινοσκόπηση. Συσχέτιση με το σκορ ασβεστίου μετρούμενο με πολυτομική αξονική τομογραφία καρδιάς

    … την πολυτομική αξονική τομογραφία καρδιάς (MDCT). Μελετήθηκε η ασβέστωση των στεφανιαίων σε ασυμπτωματικούς ενήλικες χαμηλού έως μετρίου καρδιαγγειακού κινδύνου χωρίς γνωστή στεφανιαία νόσο με πολυτομική αξονική τομογραφία και με ψηφιακή ακτινοσκόπηση καρδιάς με την τεχνολογία FPDD. Η …

    patras-thes Repository record for Ανίχνευση ασβέστωσης των στεφανιαίων αρτηριών με ψηφιακή ακτινοσκόπηση. Συσχέτιση με το σκορ ασβεστίου μετρούμενο με πολυτομική αξονική τομογραφία καρδιάς (opens in a new tab)

  14. Mehrzeilen-Detektor-Computertomographie in der Diagnostik der koronaren Herzkrankheit

    … Mehrzeilen-Detektor-CT-Angiographie (MDCTA) nicht-kalzifizierte Plaques erkannt und sowohl qualitativ als auch quantitativ bewertet werden können. Zusätzlich sollte diese Arbeit noch weitere Einsatzbereiche der MDCT-Technologie in der kardialen Diagnostik aufzeigen. Insbesondere sollte …

    lmu-germany Repository record for Mehrzeilen-Detektor-Computertomographie in der Diagnostik der koronaren Herzkrankheit (opens in a new tab)

  15. Multi-Detektor-Computertomographie der Nieren und der ableitenden Harnwege bei Patienten mit schmerzloser Makrohämaturie oder einem Urothelkarzinom in der Vorgeschichte

    … der Multi-Detektor-Computer-Tomographie (MDCT), für die Entdeckung und Lokalisation von tumorösen Veränderungen des Harntrakts. Material und Methoden: Native MDCT-Aufnahmen und MDCT-Aufnahmen mit Kontrastmittel (nephrographische Phase und CT-Urographie) der Nieren und des Harntrakts wurden …

    lmu-germany Repository record for Multi-Detektor-Computertomographie der Nieren und der ableitenden Harnwege bei Patienten mit schmerzloser Makrohämaturie oder einem Urothelkarzinom in der Vorgeschichte (opens in a new tab)

Page 1 of 6