Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 254 for “"meas"”.
-
The Declining Success of MEAs: The Impact of Ideology on Adherence
… to multilateral environmental agreements (MEAs)? If so, can we attribute the declining success of MEAs to the recent widespread shift toward conservative ideology? Following the overwhelming success of the Montreal Protocol on Substances that Deplete the Ozone Layer, MEAs have consistently …
-
Development of Novel Thin Membrane Electrode Assemblies (MEAs) for High-Efficiency Energy Storage
… objective of this research is to develop novel MEAs coupled with the titanium-based thin/tunable LGDLs (TT-LGDLs) that has the well-controlled pore morphologies. The main achievements of this research include: (a) The TT-LGDLs can achieve superior performance due to the remarkably reduced ohmic …
-
3D Microelectrode Arrays (MEAs) For The Study And Interrogation Of Electrogenic Cells In Fabricated Microenvironments
Recent advances in the complexity of in vitro biological systems have enabled new possibilities for "Organ-on-a-Chip" systems with greater physiological relevancy. Microphysiological Systems (MPS) represent one such advance which incorporates a sophisticated biological construct with a custom …
-
DEVELOPMENT AND APPLICATION OF FLEXIBLE DUAL-SIDED MICROELECTRODE ARRAYS(MEAS) FOR ADVANCED BIOELECTRONIC SENSING AND NEURAL INTERFACING
Thesis (Ph.D.)--Michigan State University. Neuroscience - Doctor of Philosophy, 2025
-
Micro/nanofabrication Process Development and Device Characterization Towards Tri-Modal (Optical, Electrical, and Microfluidic) 3D Microelectrode Arrays (3D MEAs)
… fabricated toward 3D Microelectrode Arrays (3D MEAs) with tri-modal functionality for obtaining simultaneous data sets comprising electrical, optical, and microfluidic markers from a variety of electrogenic cellular constructs. 3D MEAs are the next-generation interfaces to transduce multi-modal …
-
Study of Tantalum Carbide Supported Iridium-Based Catalyst and Sulfonated Phenylated Polyphenylene as Materials for Polymer Electrolyte Membrane Water Electrolysis
… acid (PFSA) based membrane electrode assemblies (MEAs) and sulfonated phenylated polyphenylene (sPPP) based MEAs. The Mayer bar method and the automated fluid dispenser method were compared as methods to prepare the electrodes. The Mayer bar method was selected due to the small amount of ink …
-
Thermodynamic Based Model Eliciting Activities for Undergraduate Mechanical Engineering Education
… modern workplace. Model Eliciting Activities (MEAs) allow students to think critically about their own work and allow instructors to analyze the students’ problem solving methods. To ensure that new MEAs are as effective as possible they are subject to six basic principles: model construction, …
-
The Effect of Catalyst Layer Cracks on the Mechanical Fatigue of Membrane Electrode Assemblies
Mechanical fatigue testing has shown that MEAs (membrane electrode assemblies) fail at lower stresses than PEMs (proton exchange membranes) at comparable times under load. The failure of MEAs at lower stresses is influenced by the presence of mud cracks in the catalyst layers acting as stress …
-
Development of 3D Printed and 3D Metal-Based Micro/Nanofabricated, and Nano-Functionalized, Microelectrode Array (MEA) Biosensors For Flexible, Conformable, and In Vitro Applications
… rapid development of 3D Microelectrode Arrays (MEAs) for electrical interfacing with biological constructs. The work reported in this thesis focuses on two developmental tracks: "Dynamic 3D MEAs" and metal microfabrication for 3D MEAs. In the first part of the thesis, we explore the capabilities …
-
Investigating Gulf Coast Aquifer System: Stratigraphy Reconstruction, Inverse Modeling, and Groundwater Stress Assessment
The Mississippi Embayment aquifer system (MEAS) and the Coastal Lowlands aquifer system (CLAS) provide substantial groundwater resources for human activities in the U.S. Gulf Coastal Plain. However, the overexploitation has led to groundwater depletion in the MEAS and the CLAS, threatening …
-
Advancing three-dimensional electrophysiology: Development and evaluation of versatile platform for tailored 3D microelectrode array fabrication
Microelectrode arrays (MEAs) are widely used tools to investigate in vitro neuronal networks and acute brain slices. Planar or 2D MEAs have been the conventional standard for decades, enabling the extracellular recording and stimulation of cultured neuronal cells and tissue slices. However, the …
-
Polymer-based and Functionalized 3D Microelectrode Array (MEA) Biosensors
… (2D) cell cultures. Microelectrode arrays (MEAs) are biosensors used to spatially and temporally monitor the activity of microphysiological systems by transducing cellular signals into electronic signals to provide quantitative data on the in vitro system. Conventional MEAs are typically …
-
Micromachined three-dimensional electrode arrays for in-vitro and in-vivo electrogenic cellular networks
… three-dimensional microelectrode arrays (3-D MEAs) targeted toward in-vitro and in-vivo biomedical applications. Current 3-D MEAs are predominantly silicon-based, fabricated in a planar fashion, and are assembled to achieve a true 3-D form: a technique that cannot be extended to …
-
Membrane Electrode Assembly (MEA) Design for Power Density Enhancement of Direct Methanol Fuel Cells (DMFCs)
… different manufacturing processes for patterning MEAs with corrugations have been investigated. A folding process was selected to form 2D triangular corrugations on MEAs for experimental validations of the performance prediction. The experimental results show that the volumetric power densities of …
-
Corrosion of bipolar plates in PEM fuel cells
… contaminants in membrane electrode assemblies (MEAs) which were used in proton exchange membrane fuel cell (PEM FC) stacks. The laboratory XRF results were consistent with the synchrotron XRF results. Higher levels of contaminants observed for the areas near to the coolant outlet than the areas …
-
Expanding the Capabilities of 3d Microelectrodes Arrays with A Multi-Material Palette and A 6-Well Flex Circuit System
… identify device (3D Microelectrode Arrays – 3D MEAs)/system (commercial electronics interface) issues preventing the scaling up of the world’s first in vitro model of afferent synaptic signaling in the spinal cord and develop a potential solution involving spin cast insulation and …
-
3D Shell MEA to Record Electrical Activity of Brain Organoids
… in the brain utilizing Multielectrode Arrays (MEAs). MEAs allow for both the recording and the stimulation of electrical activity from electrogenic–involving the production of changes in electric potential–cells. Conventional MEAs are two dimensional (2D) in nature. They were designed …
-
Model eliciting activities : an assessment framework in a middle school science context
… two difficulties arise in the implementation of MEAs: (1) assessing the quality of the tasks involved in MEAs, and (2) assessing student knowledge demonstrated through MEAs (Wang et.al., 2009). This report reviews the literature on assessing MEAs and focuses on the development of a generalized …
-
Design of Microelectrode Arrays for The Dnaorigami Orientation Control and the Long-Term Stable Measurement of Bacteria
Microelectrode arrays (MEAs) have great potential in a variety of emerging applications, including brain-machine interfaces (BMIs), point-of-care (PoC) devices, in vitro drug screening, molecular sensing, and bio-microelectromechanical systems (bioMEMs). Also, electrical signals can be delivered …
-
Neurophysiology and electrophysiology of human and murine dental pulp stem cells.
… biocompatibility. Microelectrode arrays (MEAs) approximate the brain-machine interface in vitro. In Chapter 3 I designed and fabricated a novel MEA with design features specific to our research goals. Initial characterisation of these MEAs in comparison with commercial MEAs demonstrated …
Page 1 of 13