  1. Cardiac Output Improvement in Mechanical Circulatory Support Devices

    Mechanical circulatory support devices (MCSDs) have gained widespread clinical acceptance as an effective heart failure (HF) therapy. The concept of harnessing the kinetic energy (KE) available in the forward aortic flow (AOF) is proposed as a novel control strategy to further increase the cardiac …

    ndsu Repository record for Cardiac Output Improvement in Mechanical Circulatory Support Devices (opens in a new tab)

  2. Mechanical circulatory support in patients with acute cardiogenic shock

    … and is associated with high mortality. Temporary mechanical circulatory support (MCS) is widely used for CS therapy. In our research, we investigated and compared different temporary MCS concepts based on microaxial intraaortic impeller pumps. Methods The data of all patients who received MCS with …

    fu-berlin Repository record for Mechanical circulatory support in patients with acute cardiogenic shock (opens in a new tab)

  3. The importance of pulsatility in modern mechanical circulatory support devices

    … numerically inadequate solution. Modern durable mechanical circulatory support (MCS) devices, such as ventricular assist devices (VADs) can provide bridging therapy to transplantation, or alternatively function as a destination therapy. These devices lack pulsatility which has important …

    unsw Repository record for The importance of pulsatility in modern mechanical circulatory support devices (opens in a new tab)

  4. Enhancing Flow-Related Haemocompatibility in Mechanical Circulatory Support: Computational and Experimental Approaches

    … treatments. Fully implantable pumps to support the heart, known as ventricular assist devices (VADs), have thus gained importance as long-term treatment options. Although outcomes of treatment with VADs have greatly improved, their use is still associated with higher complication rates …

    zurich

  5. Resolving Flow Properties of Spiral Groove Bearings to Improve Mechanical Circulatory Support Hemocompatibility

    … destination, and bridge to recovery devices to support a failing heart. These pumps unload the ventricles (ventricular assist devices) or replace the heart entirely (total artificial hearts), using impellers, or a rotating set of blades, to drive blood flow to the systemic and/or pulmonary …

    rice Repository record for Resolving Flow Properties of Spiral Groove Bearings to Improve Mechanical Circulatory Support Hemocompatibility (opens in a new tab)

  6. Addressing the heart failure epidemic: from mechanical circulatory support to stem cell therapy

    … into three major groups: pharmaceutical therapy, mechanical circulatory support, or cell-based therapy. Pharmaceutical therapies are used in the earlier stages of disease progression or to manage symptoms and comorbidities of later stage heart failure. Mechanical circulatory support is often …

    bu Repository record for Addressing the heart failure epidemic: from mechanical circulatory support to stem cell therapy (opens in a new tab)

  7. A comparison of outcomes among the patients with mechanical circulatory support devices and heart transplantation /

    … and advanced therapies such as durable mechanical circulatory support, particularly left ventricular assist devices, and orthotopic heart transplantation must be considered. Heart transplantation has traditionally been regarded as the gold-standard treatment for eligible patients, but …

    vilnius Repository record for A comparison of outcomes among the patients with mechanical circulatory support devices and heart transplantation / (opens in a new tab)

  8. The Evolving Landscape Of Mechanical Circulatory Support In The United States: Observations From National Registries

    Mechanical circulatory support (MCS) is a rapidly evolving field. This dissertation describes trends in patient selection, device utilization, and outcomes for adult and pediatric patients receiving MCS in the United States by examining data from two national registries. Trends in adult MCS device …

    uab Repository record for The Evolving Landscape Of Mechanical Circulatory Support In The United States: Observations From National Registries (opens in a new tab)

  9. Early diagnosis of cardiogenic shock: which patients should receive mechanical circulatory support? early diagnosis is half the battle /

    … of the underlying cause, possible initiation of mechanical circulatory support (MCS) and correction of end-organ hypoperfusion to prevent or reverse organ failure. Materials and methods. A review based on scientific literature was conducted using the international database PubMed, Scopus, Google …

    vilnius Repository record for Early diagnosis of cardiogenic shock: which patients should receive mechanical circulatory support? early diagnosis is half the battle / (opens in a new tab)

  10. Acute mechanical circulatory support in the cardiovascular ICU: Investigating the effects of an interactive cardiovascular dynamics simulation program on nursing clinical judgment.

    Introduction: Education on acute mechanical circulatory support (AMCS), a therapy used in the cardiovascular intensive care unit (CICU) to manage cardiogenic shock (CGS) is limited for CICU nurses. There is a need to explore clinical judgment in CICU nurses and provide innovative learning …

    louisville Repository record for Acute mechanical circulatory support in the cardiovascular ICU: Investigating the effects of an interactive cardiovascular dynamics simulation program on nursing clinical judgment. (opens in a new tab)

  11. Development and applications of in-vitro and in-silico models of the cardiovascular system to study the effects of mechanical circulatory support.

    … was developed to recreate the physiological mechanical stimulants in the vascular wall. The results demonstrated different effects of pulsatile shear stress and stretch on endothelial cells and may indicate that a pulse pressure of at least 30 mmHg is needed to maintain normal endothelial …

    louisville Repository record for Development and applications of in-vitro and in-silico models of the cardiovascular system to study the effects of mechanical circulatory support. (opens in a new tab)

  12. Expanding the Performance Envelope of the Total Artificial Heart: Physiological Characterization, Development of a Heart Failure Model, And Evaluation Tool for Mechanical Circulatory Support Devices

    … year. With shortages in available donor hearts, mechanical circulatory support (MCS) has emerged as a life-saving treatment for advanced stage HF. With growth in MCS use, a clinical and developmental need has emerged for a standard characterization and evaluation platform that may be utilized for …

    arizona-thes Repository record for Expanding the Performance Envelope of the Total Artificial Heart: Physiological Characterization, Development of a Heart Failure Model, And Evaluation Tool for Mechanical Circulatory Support Devices (opens in a new tab)

  13. An Examination of Spiritual and Religious Coping and Well-Being and their Impact on the Health-Related Quality of Life for Patients with Mechanical Circulatory Support

    Mechanical Circulatory Support (MCS) improves the health-related quality of life (HRQOL) for patients with end-stage heart failure (HF) (Friedrich & Bohm, 2007). Religious and spiritual practices positively influence health and well-being for cardiac patients (Ai, Park, Huang, Rodgers, & Tice, …

    vcu Repository record for An Examination of Spiritual and Religious Coping and Well-Being and their Impact on the Health-Related Quality of Life for Patients with Mechanical Circulatory Support (opens in a new tab)

  14. Investigating the effects of novel heart failure treatment modalities on the autonomic nervous system

    … devices that improve cardiac function, such as mechanical circulatory support and pacemakers. Both are postulated to alter autonomic balance to effector organs, especially the heart and kidney, which may aid recovery. The assessment of autonomic activity to these vital organs in critically ill …

    auckland-ms Repository record for Investigating the effects of novel heart failure treatment modalities on the autonomic nervous system (opens in a new tab)

  15. Vaikų širdies transplantacijos rezultatai Lietuvoje /

    … transplantation, organ waiting time, need for mechanical circulatory support before transplantation and mortality. Results: The study sample consisted of 22 patients: 16 (72.7%) boys and 6 (27.3%) girls. Patients were divided into three age groups: infants from birth until 12 months of age …

    vilnius Repository record for Vaikų širdies transplantacijos rezultatai Lietuvoje / (opens in a new tab)

  16. Outcomes after Apheresis in patients with underlying Heart Failure: A Propensity Matched National Cohort Analysis

    … sudden cardiac arrest, cardiogenic shock, mechanical circulatory support, mechanical ventilation, calcium abnormalities, fluid and electrolyte disturbances, coagulation abnormalities, and severe sepsis. Results: Apheresis in patients with HF had a higher percentage of in-hospital mortality, …

    ku Repository record for Outcomes after Apheresis in patients with underlying Heart Failure: A Propensity Matched National Cohort Analysis (opens in a new tab)

  17. Kardiogeninis šokas: Kada naudoti pagalbinius prietaisus? /

    … in 1,5 % of patients, necessitating the use of mechanical circulatory support devices. An ideal mechanical circulatory device is described as a tool that ensures effective and reliable circulatory support, is easily and quickly deployed, is typically managed and monitored during application, and …

    vilnius Repository record for Kardiogeninis šokas: Kada naudoti pagalbinius prietaisus? / (opens in a new tab)

  18. Langzeitüberleben und kardiozerebrovaskuläre Komplikationen nach CABG versus LVAD-Implantation bei koronarer Herzkrankheit und stark reduzierter LV-Funktion

    … approximately 50% required inotropic support, and 20% received preoperative mechanical circulatory support. Compared with CABG, LVAD implantation was associated with substantially prolonged ventilation (median 58 h vs. 16 h, p <0.001) and longer ICU stay (11 vs. 4 days, p ≤ 0.001). …

    fu-berlin Repository record for Langzeitüberleben und kardiozerebrovaskuläre Komplikationen nach CABG versus LVAD-Implantation bei koronarer Herzkrankheit und stark reduzierter LV-Funktion (opens in a new tab)