Incorporating Solar Technology to Design in Humid Subtropical Climates
… sun and creating air circulation for evaporative cooling. Today's photovoltaic technology can activate vernacular principles and create new sustainable typologies. Unlike tropical climates, the humid subtropical deals with high relative humidity in the summer months, thus demanding the use of …
-
Enabling VOLTTRON: Energy Management of Commercial Buildings at the University of Maryland
… National Laboratory, was used to disable the mechanical cooling of a rooftop unit (RTU) during unoccupied hours, on a building without a BAS. With cooling off, the RTU’s electricity dropped from ~18 kW to ~7kW. These results indicate $450 to $550 can be saved on the monthly electric bill of …
-
Characterising window design parameters based on occupant behaviour and preferences in single-dwelling residential buildings to reduce energy demand for ventilation in Melbourne
… high potential for passive ventilation, yet mechanical cooling use continues to rise. The aim of this research is to develop and test a behaviour-informed (BI) simulation framework that explicitly integrates empirically derived occupant window-use behaviour with key window design parameters …
-
EXPERIMENTAL AND NUMERICAL STUDY OF A PASSIVE COLD THERMAL ENERGY STORAGE SYSTEM
Water scarcity and the inefficiencies of current cooling systems highlight the need for alternative cooling solutions. This study presents a cold thermal energy storage (CTES) system designed to store cold thermal energy during nighttime and release it during daytime operations. The experimental …
-
Evaluation of Existing Subsurface Cooling Systems Worldwide and Development of Efficient Cooling Methods and Systems Based on Renewable Energy Sources
… of mitigating heat will require substantial cooling capacity in some cases. For deep deposits to be mined at increasing depths, mechanical cooling systems used to maintain an acceptable underground climate will most surely become increasingly complex and expensive, which most certainly …
-
The development of passive downdraught evaporative cooling systems using porous ceramic evaporators and their application in residential buildings
Passive Evaporative Cooling is a method that uses the evaporation of water to cool the air. It is traditionally used and is most suitable in hot and dry climates. Its application is based on the availability of water resources and the creation of air movement through the building. The use of clay …
-
Phase Change Materials as a Thermal Storage Device for Passive Houses
… House with a 1500 Watt electric heater and no mechanical cooling was modeled. The effectiveness of the PCM was determined by comparing the zone-hours and zone-degree-hours outside the ASHRAE defined comfort zone for all PCM cases against a control simulation without PCM. Results show that …
-
Adapting Nordic Buildings for Enhanced Summertime Resilience in the Face of Climate Change
… However, results showed that there is a need for mechanical cooling systems in residential buildings to ensure comfortable and healthy indoor temperatures during current and future heat events. The needed cooling electricity was shown to be considerably small compared to other energy consumptions …
-
Improving Thermal Comfort Conditions in K-12 Educational Buildings in Hot and Humid Climate
… This school is a concrete structure without mechanical cooling. It has features such as vertical louvers and light shelves to provide solar shading and cross ventilation. However, field observation discovered that 82% of the time, students experienced thermal and visual discomfort in …
-
Characterization of Mechanically Cooled High Purity Germanium (HPGe) Detectors at Elevated Temperatures
… bandgap (~0.7 eV) of HPGe. Liquid nitrogen or mechanical cooling is required to achieve such temperatures.</p> <p>This dissertation presents work performed to characterize energy resolution performance as a function of temperature in a new mechanically cooled HPGe detector design based upon a …
-
An evaluation of ground pipe ventilation and overnight radiant cooling to displace air conditioning in Nigeria
… electricity generators, primarily to maintain mechanical cooling and food preservation. Energy consumption is expected to rise as most new buildings don ot incorporate any significant energy saving techniques that could reduce cooling demands. Providing a solution to this becomes a major …
-
Sculpting the 'Aesthetics of Air' for Improved Thermal Comfort: Testing a Skip-Stop Double Loaded Corridor Spatial Configuration for Naturally Ventilated High-Density Buildings in Hot and Humid Climates
… interest in utilizing natural ventilation cooling in future high rise buildings. The use of natural ventilation cooling is not new to hot and humid regions of the world, yet this passive design principle found in tropical vernacular architecture is not found in many tall buildings in the …
-
The value of school environmental monitoring in a time of change
… However, aging school buildings, outdated mechanical systems, limited school indoor environmental policies, and constrained budgets are slowing improvements in classroom indoor environmental quality (IEQ). These challenges can be exacerbated by climate change and have potential lasting …
-
Development of an Improved PCM-to-Air Heat Exchanger for Building Envelopes - Advancement to Free Cooling Applications
… thermal energy storage systems toward reducing cooling load has been increased in recent years. In this study, the utilization of phase change materials (PCMs) has been comprehensively discussed for building free cooling applications. The potential and limitations of using PCM-to-Air Heat …
-
Modeling on single-sided wind-driven natural ventilation
… of this energy being used for ventilation and cooling. Despite the large amount of energy used in buildings, reports have shown that the indoor air quality (IAQ) and thermal comfort are not satisfactory. The lowered productivity due to the bad IAQ could cause $125 billion loss per year and the …
-
Evaluating the Impact of Fan Design and Air Speed on User and Nearby Occupants’ Thermal Comfort in a Shared Office
… of other occupants. Desk fans are common PCS cooling devices, but their use in shared workspaces raises questions about the differential impact on the primary user and nearby occupants. Limited empirical evidence exists on how local air speed and fan technology jointly influence thermal, …
-
Advanced Thermal Management for Internal Combustion Engines
The automotive cooling system has unrealized potential to improve internal combustion engine performance through enhanced coolant temperature control and reduced parasitic losses. Advanced automotive thermal management systems use controllable actuators (e.g., smart thermostat valve, variable speed …
-
AC/DC: Let There Be Hybrid Cooling
… cool occupants with passive methods, as well as mechanical methods. In the subtropics, where buildings often need to be heated in the winter and cooled in the summer, a synthesis of these two methods would be ideal. However, there is a disconnect between the integration of passive cooling and …