  1. Blood flow dynamics through a defective mechanical heart valve

    A model of asymmetrical 2-D defective bileaflet mechanical heart valve was used to simulate steady and pulsatile blood flow through a defective mechanical heart valve under several flow and malfunction severity conditions. The calculations used Reynolds-averaged Navier-Stokes equations with …

    concordia

  2. Developing, testing, and fabricating a novel bileaflet mechanical heart valve : the iValve

    Valvular heart disease primarily affects the aortic and mitral valves due to higher left-sided heart pressures, often leading to complications like leaflet calcification (stenosis), which impairs valve function and can result in congestive heart failure, necessitating valve replacement. Three forms …

    ubc Repository record for Developing, testing, and fabricating a novel bileaflet mechanical heart valve : the iValve (opens in a new tab)

  3. Fluid Dynamics Modeling and Sound Analysis of a Bileaflet Mechanical Heart Valve

    … of death in the world. Some CVD involve severe heart valve disease that require valve replacement. There are more than 300,000 heart valves implanted worldwide, and about 85,000 heart valve replacements in the US. Approximately half of these valves are mechanical. Artificial valves may …

    ucf Repository record for Fluid Dynamics Modeling and Sound Analysis of a Bileaflet Mechanical Heart Valve (opens in a new tab)

  4. Experimental investigation of the fluid dynamic aspects of a bileaflet mechanical heart valve

    Turbulent flow downstream of a bileaflet mechanical heart valve is investigated using digital particle image velocimetry. Evolution of flow structures during the systole and diastole phases of a typical cardiac cycle is characterized by obtaining global flow velocity measurements in multiple …

    uvic Repository record for Experimental investigation of the fluid dynamic aspects of a bileaflet mechanical heart valve (opens in a new tab)

  5. Restarting Oral Anticoagulant in Patients with Mechanical Heart Valve(s) and Intracranial Haemorrhage

    Patients with mechanical heart valves who present with intracranial haemorrhage are initially treated by reversing their coagulopathy. However, these patients will ultimately require that their oral anticoagulant be restarted. The time at which oral anticoagulants are restarted is critical since …

    ottawa-retro Repository record for Restarting Oral Anticoagulant in Patients with Mechanical Heart Valve(s) and Intracranial Haemorrhage (opens in a new tab)

  6. The application of passive flow control to bileaflet mechanical heart valve leakage jets

    Bileaflet mechanical heart valves (BMHVs), though a life-saving tool in treating heart valve disease, are often associated with serious complications, including a high risk of hemolysis, platelet activation, and thromboembolism. One likely cause of this hyper-coagulative state is the nonphysiologic …

    gatech Repository record for The application of passive flow control to bileaflet mechanical heart valve leakage jets (opens in a new tab)

  7. A helical finite element applied to the vibration analysis of a mechanical heart valve

    … technique for evaluation of implanted artificial heart valves by an analysis of their acoustic signature, the helical element is used to model and analyze the vibration of the struts of a Bjork-Shiley tilting disc valve. The natural frequencies thus determined are compared with the exper­imentally …

    uvic Repository record for A helical finite element applied to the vibration analysis of a mechanical heart valve (opens in a new tab)

  8. Numerical and Experimental Investigations of Pulsatile Blood Flow through a Dysfunctional Mechanical Heart Valve

    Despite the marked improvement in prosthetic heart valve design and functionality, thromboembolism, structural failure, endocarditis and hemolysis are still possible complications. In such cases, native heart valve disease is replaced with “prosthetic heart valve disease”. Bileaflet Mechanical …

    concordia

  9. Measurements of Flow Through a Bileaflet Mechanical Heart Valve in an Anatomically Accurate Model of the Aorta

    … the flow characteristics past a bileaflet mechanical heart valve (BMHV) in an anatomical model of the aorta. The measurements were made within a mock circulation loop that produced physiological pressure and flow conditions of the aorta. The velocity was measured upstream and downstream of …

    ottawa-retro Repository record for Measurements of Flow Through a Bileaflet Mechanical Heart Valve in an Anatomically Accurate Model of the Aorta (opens in a new tab)

  10. In vitro micro particle image velocimetry measurements in the hinge region of a bileaflet mechanical heart valve

    … for thromboembolic complications in bileaflet mechanical heart valves (BMHV), primarily due to the complex and unsteady flows in the valve hinges. These studies have focused on quantitative and qualitative parameters such as velocity magnitude, turbulent shear stresses, vortex formation and …

    gatech Repository record for In vitro micro particle image velocimetry measurements in the hinge region of a bileaflet mechanical heart valve (opens in a new tab)

  11. IN VITRO VISUALIZATION OF PEDIATRIC SIZED MECHANICAL HEART VALVE PERFORMANCE USING AORTIC ROOT MODEL IN MOCK CIRCULATORY LOOP

    Congenital heart valve disease is one of the most common abnormalities in children, with common valve defects being aortic stenosis, mitral stenosis, and valvular regurgitation. Although adult sized mechanical heart valve (MHV) replacements are widely studied and utilized, there are currently no …

    vcu Repository record for IN VITRO VISUALIZATION OF PEDIATRIC SIZED MECHANICAL HEART VALVE PERFORMANCE USING AORTIC ROOT MODEL IN MOCK CIRCULATORY LOOP (opens in a new tab)

  12. In Vitro Evaluation of Mechanical Heart Valve Performance Using a Novel Test Chamber in an Automated Mock Circulatory Loop

    Valvular heart disease (VHD) continues to have significant effects on many people’s lives, with numbers expected to grow tremendously over the next few years. Individuals suffering from severe valvular heart disease usually require a heart valve transplant in order to restore the native valve’s …

    vcu Repository record for In Vitro Evaluation of Mechanical Heart Valve Performance Using a Novel Test Chamber in an Automated Mock Circulatory Loop (opens in a new tab)

  13. The Development of a Novel in vitro Flow System to Evaluate Platelet Activation and Procoagulant Potential Induced by Bileaflet Mechanical Heart Valve Leakage Jets

    Bileaflet mechanical heart valves (BMHVs) are prone to thrombus formation in the hinge region due to high shear stress combined with stagnation regions. This thesis research addresses the hypothesis that models that isolate and mimic BMHV hinge geometries can be used to quantitatively characterize …

    gatech Repository record for The Development of a Novel in vitro Flow System to Evaluate Platelet Activation and Procoagulant Potential Induced by Bileaflet Mechanical Heart Valve Leakage Jets (opens in a new tab)

  14. Blutgerinnungsmanagement nach mechanischem Herzklappenersatz

    … Self-Management of oral Anticoagulation after mechanical heart valve replacement – Long term experience of the Department of Heart Surgery Ludwig-Maximilians-University Munich. Objectives: Lifelong oral anticoagulation treatment (OAT) is necessary after mechanical heart valve replacement. This …

    lmu-germany Repository record for Blutgerinnungsmanagement nach mechanischem Herzklappenersatz (opens in a new tab)

  15. 3-DIMENSIONAL NUMERICAL AND EXPERIMENTAL STUDIES TO MODEL ARTIFICIAL HEART VALVES HEMODYNAMICS

    The characterization of the artificial heart valves flow fields is a crucial step to evaluate the performances on improving heart valve engineering. With the advancement of Computational Fluid Dynamics, we are able to study the complex hemodynamics in details such as stagnation, recirculation zones …

    nus Repository record for 3-DIMENSIONAL NUMERICAL AND EXPERIMENTAL STUDIES TO MODEL ARTIFICIAL HEART VALVES HEMODYNAMICS (opens in a new tab)

  16. ΕΝΔΟΑΓΓΕΙΑΚΗ ΑΙΜΟΛΥΣΗ ΣΕ ΑΡΡΩΣΤΟΥΣ ΜΕ ΦΥΣΙΟΛΟΓΙΚΩΣ ΛΕΙΤΟΥΡΓΟΥΣΕΣ ΤΕΧΝΗΤΕΣ ΚΑΡΔΙΑΚΕΣ ΒΑΛΒΙΔΕΣ

    … COMMON AMONG PATIENTS WITH NORMALLYFUNCTIONING MECHANICAL HEART VALVE PROSTHESES AND MAY BE FOUND 40-85% OF THEM. IN MOST OF THE CASES HEMOLYSIS IS SUBCLINICAL BUT IN 2.5-15% IT MAY BE SEVERE ENOUGH TO CAUSE ANAEMIA OR NECCESSITATE REPLACEMENT OF THE PROSTHESIS. WEEVALUATED HEMOLYSIS IN 170 …

    greece Repository record for ΕΝΔΟΑΓΓΕΙΑΚΗ ΑΙΜΟΛΥΣΗ ΣΕ ΑΡΡΩΣΤΟΥΣ ΜΕ ΦΥΣΙΟΛΟΓΙΚΩΣ ΛΕΙΤΟΥΡΓΟΥΣΕΣ ΤΕΧΝΗΤΕΣ ΚΑΡΔΙΑΚΕΣ ΒΑΛΒΙΔΕΣ (opens in a new tab)

  17. Experimental study of flow pulse interacting with walls

    … of the flexible structures. Extended to biomechanical field, the wall shear stress (WSS) induced by the natural flow pulse during the systolic beat of the heart is investigated in a transparent model of the human aorta. A traditional mechanical valve prosthesis, the SJM Regent bileaflet …

    city-london Repository record for Experimental study of flow pulse interacting with walls (opens in a new tab)

  18. Signal processing of heart signals for the quantification of non-deterministic events

    The issue of cavitation in mechanical heart valve (MHV) patients was first recognized when damaged mechanical heart valves were observed. Cavitation bubble implosion can cause mechanical damage to the valve structure and blood elements, when it occurs near the surface of the MHV. Some methods have …

    ottawa-retro Repository record for Signal processing of heart signals for the quantification of non-deterministic events (opens in a new tab)