Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 42 for “"mechanical heart valves"”.
-
Okanagan valve : the next generation of mechanical heart valves
Valvular heart disease is a cardiovascular condition characterized by damage to any number of the four valves within the human heart. This damage can be defined as stenosis or incompetence based on a valve’s inability to completely open or close, respectively. Stenosis and incompetence are caused …
-
Application of the Direct Oral Anticoagulants to Thromboprophylaxis of Mechanical Heart Valves
Patients with valvular pathology who require heart valve replacement surgery are faced with the option between a bioprosthetic heart valve (BHV) or a mechanical heart valve (MHV). BHVs have a limited lifespan and are prone to structural degeneration. In contrast, MHVs are free from structural …
-
Numerical simulation of the leaflet designs to improve hemodynamics of mechanical heart valves
Mechanical heart valves (MHVs) are widely implanted due to their reliability and long life span. However, patients who receive MHV implants are required and prescribed anticoagulant medication to reduce the high risk of thromboembolic complications. Although MHVs are considered as a long-term …
-
Numerical simulations of the micro flow field in the hinge region of bileaflet mechanical heart valves
Native heart valves with limited functionality are commonly replaced by a bileaflet mechanical heart valve (BMHV). However, despite their widespread use, BMHVs still cause major complications, including hemolysis, platelet activation, and thromboembolic events. These complications are believed to …
-
Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves
Native heart valves that have limited functionality due to cardiovascular disease or congenital birth defects are commonly replaced by prosthetic heart valves. Bileaflet mechanical heart valves (BMHV) are the most commonly implanted valve design due to their long-term durability. However, their …
-
Haemorrhage and Other Complications in Pregnant Women on Anticoagulation for Mechanical Heart Valves; a Prospective Observational Cohort Study
… in anticoagulated, pregnant patients with mechanical heart valves until 42 days postpartum. Methods: In a tertiary single-centre, prospective cohort, 178 consecutive patients at the cardiac-obstetric clinic were screened for warfarin use between 1 July 2010 and 31 December 2015. Of 33 …
-
A novel design for the housing of bileaflet mechanical heart valves (St. Jude medical model) : a computational approach
The St. Jude Medical (SJM) bileaflet mechanical heart valve (MHV) was approved by the Food and Drug Administration in the late 70’s. The basic idea for the design of the valve is simply two semicircular flat plates pivoting on recessed hinges. The SJM valve provides improved hemodynamics compared …
-
Simulations of pulsatile flow through bileaflet mechanical heart valves using a suspension flow model: to assess blood damage
Defective or diseased native valves have been replaced by bileaflet mechanical heart valves (BMHVs) for many years. However, severe complications still exist, and thus blood damage that occurs in BMHV flows must be well understood. The aim of this research is to numerically study platelet damage …
-
Application of passive flow control to mitigate the thromboembolic potential of bileaflet mechanical heart valves: an in-vitro study
Implantation of a bileaflet mechanical heart valve (BMHV) continues to be associated with risk of thromboembolic complications despite anti-coagulation therapy. Mechanical heart valves have been the gold standard in valve heart replacement since the 1950s with BMHVs currently still being the valve …
-
3-DIMENSIONAL NUMERICAL AND EXPERIMENTAL STUDIES TO MODEL ARTIFICIAL HEART VALVES HEMODYNAMICS
The characterization of the artificial heart valves flow fields is a crucial step to evaluate the performances on improving heart valve engineering. With the advancement of Computational Fluid Dynamics, we are able to study the complex hemodynamics in details such as stagnation, recirculation zones …
-
Hemocompatibility of hyaluronan enhanced linear low-density polyethylene for heart valve leaflet applications
Heart valve disease is a major concern in both developed countries with advanced ageing populations and undeveloped countries which experience a high incidence of rheumatism leading to valvular disease. To reduce mortality and improve quality of life, heart valve implantations have been widely used …
-
In vitro micro particle image velocimetry measurements in the hinge region of a bileaflet mechanical heart valve
… for thromboembolic complications in bileaflet mechanical heart valves (BMHV), primarily due to the complex and unsteady flows in the valve hinges. These studies have focused on quantitative and qualitative parameters such as velocity magnitude, turbulent shear stresses, vortex formation and …
-
Hemocompatibility of titania nanotube arrays under static and dynamic conditions
… medical devices such as vascular stents, mechanical heart valves, etc. However, the material is not always hemocompatible, often resulting in thrombosis and eventual rejection of the medical device. To overcome this, medical practitioners have used anti coagulating methods which have had …
-
IN VITRO VISUALIZATION OF PEDIATRIC SIZED MECHANICAL HEART VALVE PERFORMANCE USING AORTIC ROOT MODEL IN MOCK CIRCULATORY LOOP
Congenital heart valve disease is one of the most common abnormalities in children, with common valve defects being aortic stenosis, mitral stenosis, and valvular regurgitation. Although adult sized mechanical heart valve (MHV) replacements are widely studied and utilized, there are currently no …
-
A computational framework for simulating cardiovascular flows in patient-specific anatomies
… between the blood flow and implanted bi-leaflet mechanical heart valves (BMHV). The ability of the method to resolve and illuminate the physics of dynamically rich vortex phenomena is demonstrated by carrying out simulations of impulsively driven flow through inclined nozzles and comparing the …
-
Frequency of monitoring INR measurements and intensity of anticoagulation
… or between 3.0 and 4.0 for patients with mechanical heart valves in accordance with old suggestions. According to the new findings about the relationship between INR and different complications (including death), there has been a trend towards lower target intervals [7] [8]. However, …
-
Signal processing of heart signals for the quantification of non-deterministic events
The issue of cavitation in mechanical heart valve (MHV) patients was first recognized when damaged mechanical heart valves were observed. Cavitation bubble implosion can cause mechanical damage to the valve structure and blood elements, when it occurs near the surface of the MHV. Some methods have …
-
Computational Modeling of Cardiovascular Flows using Smoothed Particle Hydrodynamics
… simulating pulsatile flow inside a model of the heart’s left ventricle and through normal and dysfunctional prosthetic mechanical heart valves. The SPH simulations result in the realistic calculation of the shear stress loading on the blood components and illustrate the important role played by …
-
Restarting Oral Anticoagulant in Patients with Mechanical Heart Valve(s) and Intracranial Haemorrhage
Patients with mechanical heart valves who present with intracranial haemorrhage are initially treated by reversing their coagulopathy. However, these patients will ultimately require that their oral anticoagulant be restarted. The time at which oral anticoagulants are restarted is critical since …
Page 1 of 3