Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"metal roof"”.

  1. Response of pierced fixed metal roof cladding to fluctuating wind loads

    The roof of a low rise building (e.g., house, industrial shed) is subjected to intense fluctuating wind pressures during a tropical cyclone. A failure of the building’s roof is not only a life safety issue but also impacts greatly on the community’s resilience during and after wind storms. Low …

    jamescook Download PDF for Response of pierced fixed metal roof cladding to fluctuating wind loads (opens in a new tab)

  2. Probabilistic damage and loss modeling for metal roof using artificial neural network

    Metal roofs are highly susceptible to hurricane wind damage. The damage to the roof is extremely significant in estimation of losses. Minor damage to the roof can augment the total loss because of the entrance of rain into the building, and subsequent interior and content loss. A probabilistic …

    ttu Repository record for Probabilistic damage and loss modeling for metal roof using artificial neural network (opens in a new tab)

  3. REDUCING SOLAR HEAT GAIN THROUGH METAL ROOF SYSTEMS: POTENTIAL OF REFLECTIVE COATING

    Effect of reflective coating on metal roof was studied with the help of three identical model houses constructed at the rooftop of Block Two of the Faculty of Architecture, Building and Real Estate of the National University of Singapore. Temperature recordings were made through thermocouples …

    nus Repository record for REDUCING SOLAR HEAT GAIN THROUGH METAL ROOF SYSTEMS: POTENTIAL OF REFLECTIVE COATING (opens in a new tab) Download file for REDUCING SOLAR HEAT GAIN THROUGH METAL ROOF SYSTEMS: POTENTIAL OF REFLECTIVE COATING (opens in a new tab)

  4. Experimental Determination of Required Lateral Restraint Forces for Z-Purlin Supported, Sloped Metal Roof Systems

    … restraint forces in Z-purlin supported, sloped metal roof systems under gravity loads. A proposed prediction equation, relying heavily on engineering principles, has been developed because the current provisions in the specification are empirical and based on statistical analysis. The provisions …

    vt Repository record for Experimental Determination of Required Lateral Restraint Forces for Z-Purlin Supported, Sloped Metal Roof Systems (opens in a new tab)

  5. THERMAL PERFORMANCE OF METAL ROOFING PAINT

    … ceramic coatings and porcelain enamel coating metal roof were studied with the use of thermocouples to measure temperatures on three identical models of each brick wall and timber wall constructed at the rooftop of the Faculty of Architecture, Building and Real Estate, National University of …

    nus Repository record for THERMAL PERFORMANCE OF METAL ROOFING PAINT (opens in a new tab) Download file for THERMAL PERFORMANCE OF METAL ROOFING PAINT (opens in a new tab)

  6. In-Situ Measurement of Wind Loads for Roof Edge Metal Configurations

    The role of a roof on any building is to separate the interior environment of the building from the exterior environment, thereby making it a crucial component of the building design. Metal roof edges are the first line of defense against wind-induced loads on the roof system; however, data on the …

    ottawa-retro Repository record for In-Situ Measurement of Wind Loads for Roof Edge Metal Configurations (opens in a new tab)

  7. Cold-Formed Steel Behavior: Elastic Buckling Simplified Methods for Structural Members with Edge-Stiffened Holes and Purlin Distortional Buckling Strength Under Gravity Loading

    … top flange beyond the resistance of the steel roofing panel. This research describes an experimental study to explore and quantify the difference in distortional buckling flexural capacity of metal building Z-purlins treated as isolated components and Z-purlins loaded with a constant pressure …

    vt Repository record for Cold-Formed Steel Behavior: Elastic Buckling Simplified Methods for Structural Members with Edge-Stiffened Holes and Purlin Distortional Buckling Strength Under Gravity Loading (opens in a new tab)

  8. Analysis Of The Florida's Showcase Green Envirohome Water/wastewater Systems And Development Of A Cost-benefit Green Roof Optimization Model

    … captures its stormwater runoff from the green roof, metal roof and wood decking area and routes it to the sustainable water cistern. Graywater from the home (after being disinfected using ozone) is also routed to the sustainable water cistern. This water stored in the sustainable water cistern …

    ucf Repository record for Analysis Of The Florida's Showcase Green Envirohome Water/wastewater Systems And Development Of A Cost-benefit Green Roof Optimization Model (opens in a new tab)

  9. Finite Element Analysis of the Wind - Uplift Resistance of Roof Edge Components

    Wind-induced damages on low-slope roofs are a major and common problem that many buildings located in high wind areas suffer from. Most of these damages are initiated when the metal roof edge fails first, leading to overall roof failure. This is because peak wind pressures occur at the edges and …

    ottawa-retro Repository record for Finite Element Analysis of the Wind - Uplift Resistance of Roof Edge Components (opens in a new tab)

  10. Further Study of the Gravity Loading Base Test Method

    … moment strength of gravity loaded standing seam metal roof systems is the "Base Test Method". The Base Test Method provides a means for determining the positive moment strength of a multiple span, multiple purlin line standing seam roof system using the results from a set of six single span, …

    vt Repository record for Further Study of the Gravity Loading Base Test Method (opens in a new tab)

  11. Investigation of Single Span Z-Section Purlins Supporting Standing Seam Roof Systems Considering Distortional Buckling

    … cold-formed purlins supporting a standing seam metal roof system is the 1996 AISI Specification for the Design of Cold-Formed Steel Structural Members, which contains provisions for local and lateral buckling. Previous research has determined that the AISI provisions for local buckling strength …

    vt Repository record for Investigation of Single Span Z-Section Purlins Supporting Standing Seam Roof Systems Considering Distortional Buckling (opens in a new tab)

  12. Roof Material Suitability for IT Mission-Critical Facilities

    … market research is available to determine what roof types are best suited to meet the unique demands of these buildings. The purpose of this research was to evaluate different roof materials and to observe trends relative to their lifecycle costs and roof professional’s assessment in use with …

    byu Repository record for Roof Material Suitability for IT Mission-Critical Facilities (opens in a new tab) Download PDF for Roof Material Suitability for IT Mission-Critical Facilities (opens in a new tab)

  13. Displacement-based design of concrete tilt-up walls

    … accounting for the influence of a flexible metal roof. The tilt-up panel with openings is modeled as a static frame simply supported at the ground and the roof is modeled as a simply-supported beam at the tilt-up walls. The first mode of the wall is assumed to be dominant over all other …

    ubc Repository record for Displacement-based design of concrete tilt-up walls (opens in a new tab) Download PDF for Displacement-based design of concrete tilt-up walls (opens in a new tab)

  14. THEORETICAL AND EXPERIMENTAL INVESTIGATION OF THE DYNAMIC THERMAL PERFORMANCE AND ROOF APPLICATIONS OF PHASE CHANGE MATERIAL-ENHANCED RADIATIVE COOLERS

    … gas emissions. Conventional low reflective roofs absorb a substantial amount of solar radiation, resulting in significantly elevated roof temperatures and consequently increased building cooling loads and energy consumption. Meanwhile, roofs account for approximately 25% of urban surfaces …

    unsw Repository record for THEORETICAL AND EXPERIMENTAL INVESTIGATION OF THE DYNAMIC THERMAL PERFORMANCE AND ROOF APPLICATIONS OF PHASE CHANGE MATERIAL-ENHANCED RADIATIVE COOLERS (opens in a new tab)

  15. Estimation of Required Restraint Forces in Z-Purlin Supported, Sloped Roofs Under Gravity Loads

    … lateral restraint forces in Z-purlin supported roof systems under gravity loads are in Section D3.1 of the 1996 AISI Cold-Formed Specification. The design equations contained in these provisions are empirical and based on statistical analysis. They were developed using elastic stiffness models …

    vt Repository record for Estimation of Required Restraint Forces in Z-Purlin Supported, Sloped Roofs Under Gravity Loads (opens in a new tab)

  16. Penzion pro seniory

    Tato práce má za cíl vypracovat projektovou dokumentaci pro provedení stavby. Projekt je řešen jako studie pro budoucí reálnou novostavbu Následné lůžkové péče řazené do kategorie ubytování pro seniory v lokalitě Ostrava – Vratimov. Novostavba je určena pro krátkodobý pobyt (max 3 týdny). V budově …

    brno-tech Repository record for Penzion pro seniory (opens in a new tab)

  17. Sportcentrum

    Obsahem diplomové práce je návrh projektové dokumentace občanské stavby, sportcentra, ve stupni dokumentace pro provádění stavby. Objekt je navržen jako multifunkční, kde se nachází sportovní centrum, sportbar a kavárna. Stavba je umístěna v zářezu ve svažitém terénu v oblasti občanské vybavenosti …

    brno-tech Repository record for Sportcentrum (opens in a new tab)

  18. Novostavba autoservisu se zázemím

    Diplomová práce s názvem Novostavba autoservisu se zázemím se věnuje návrhu autodílny s administrativní zázemím. Práce je rozdělena na 3 části (A – Architektonicko-stavební řešení, B – Koncepční řešení systémů TZB, C – Porovnání variant využití dešťové vody). Všechny části tvoří neoddělitelný …

    brno-tech Repository record for Novostavba autoservisu se zázemím (opens in a new tab)

  19. Vinařství Plchut

    Bakalářská práce se zabývá návrhem novostavby rodinného vinařství Plchut v Mutěnicích. Návrh vychází z projektu vypracovaného v rámci předmětu Ateliér architektonické tvorby 2 (AG032). Samotný pozemek se nachází na severozápadním svahu Zadní hory v nadmořské výšce 183 m n. m., asi 2 km od centra. …

    brno-tech Repository record for Vinařství Plchut (opens in a new tab)

  20. Construction Systems for Detached, Single-story Concrete Block Houses in Florida: Current Practices, Costs and Potential Innovations

    … are examine, it is found that two systems, roof and exterior walls, have the greatest need for changes in the immediate future; and one system, thermal insulation, needs an empirical study. The roof is of materials which are in short supply and rapidly increasing in cost. The study concludes …

    ucf Repository record for Construction Systems for Detached, Single-story Concrete Block Houses in Florida: Current Practices, Costs and Potential Innovations (opens in a new tab)

Page 1 of 2