Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 41 for “"metallic biomaterials"”
-
A Rubric for Electrochemical Testing of Metallic Biomaterials
Corrosion is a major factor for the failure of metallic medical implants. Testing a metal’s suseptability to corrosion prior to implantation is key to a successful implantation. Electrochemical processes were used in this study to evaluate the characteristics of corrosion of both AISI 316 stainless …
-
Additive manufacturing of 3D architectured metallic biomaterials by robocasting
Au-delà de l'aspect de personnalisation qu'elle peut apporter au domaine médical, la fabrication additive donne aussi accès à l'élaboration de structures cellulaires. Ces structures, de porosité maîtrisée, permettent à la fois de moduler les propriétés mécaniques de l'objet, mais aussi de favoriser …
-
Surface Engineering and Characterization of Laser Deposited Metallic Biomaterials
Novel net shaping technique Laser Engineered Net shaping (LENS) laser based manufacturing solution (Sandia Corp., Albuquerque, NM); Laser can be used to deposit orthopedic implant alloys. Ti-35Nb-7Zr-5Ta (TNZT) alloy system was deposited using LENS. The corrosion resistance being an important …
-
The Fundamentals of Fretting Crevice Corrosion of Metallic Biomaterials for Orthopedic Implants
Metallic medical devices have been widely used in clinical applications, especially for joint arthroplasty or joint replacement surgery. Fretting corrosion, one of the most common forms of mechanically-assisted corrosion (MAC), has become a major concern associated with orthopedic medical devices. …
-
The effect of bleaching agents on mineralised tooth tissues and metallic biomaterials
… to cause adverse changes to dental tissues and biomaterials. The aim of this research was to assess the effect of varying concentrations of bleaching agents on (i) tooth demineralisation and microhardness, and (ii) metal ion release from dental amalgams and casting alloys. Freshly extracted …
-
Corrosion behavior and mechanism of metallic biomaterials produced by laser powder bed fusion
… foundation for the application of L-PBF-produced metallic biomaterials in biomedical applications.
-
Surface Topographies and Mechanical Properties of Metallic Biomaterials Processed by Ultrasonic Nanocrystal Surface Modification (UNSM)
… kinds of materials for biomedical implantation, metallic biomedical implants account for a large market share due to their good mechanical properties. Successful metallic implants need to have high wear/corrosion resistance, good biocompatibility, and favorable surface topography for cells to …
-
Single Asperity Fretting Corrosion of Traditional and Additively Manufactured Metallic Biomaterials: Quantitative Analysis from Acetabular Tapers to Micron and Nanometer Scale Tribocorrosion
Mechanically assisted crevice corrosion (MACC) of metallic biomaterials continues to be a significant degradation mode. This is, in part, due to a lack of understanding of fundamental micron- and sub-micron scale mechanisms of metal degradation in biological environments. Metal-metal (or …
-
Electrochemical Assessment of Alumina-TiC Composite: A Potential Biomaterial
… composites are gaining popularity over their metallic counterparts for orthopedic applications. Metallic biomaterials, like titanium alloys and CoCrMo alloy, exhibit good performance under concentrated loads but there have been plenty cases of implant failure due to release of metallic debris …
-
In Vitro Polarization Evaluation of Carbon-Metal Galvanic Couples.
… been recognized as a problem with synthetic, metallic materials for applications in biological environments. This is one of the main reasons type 316L stainless steel and Ti-6Al-4V ELI-grade alloy have emerged as two of the more widely used metallic biomaterials. In recent years with more and …
-
Corrosion behavior of metallic bio-implant alloys
The most common metallic biomaterials are 316L, Co-28Cr-6Mo, and Ti-6Al-4V alloys used as prostheses and fixation devices. These materials are biocompatible and have high corrosion resistance. However, metallic biomaterials are not completely inert in the body. The presence of dissolved oxygen, …
-
Análise comparativa do desempenho mecânico de ligas β-Ti em implantes ortopédicos como alternativas aos biomateriais metálicos comerciais
… body. In this context, some of the commercial metallic biomaterials currently used for this type of application, such as commercially pure titanium, the Ti-6Al-4V alloy, Co-Cr-Mo alloys and Stainless Steels, have a Modulus of Elasticity value higher than the value of human bone. In addition, …
-
Ajuste das propriedades de superfície do titânio via μPPEO para melhorar a osseointegração e a adesão celular
… with direct applications in dental implants and biomaterials. μPPEO is a promising approach for surface modification of metallic biomaterials aimed at bone regeneration and drug delivery systems.
-
Surface modification of ASTM F-1537 Co-Cr alloy by low temperature plasma surface alloying
… (Co-Cr) alloys are one of the most suitable metallic biomaterials especially for high load body implants. However, recently, there are concerns over the wear of metal-on- metal artificial hip joints made from Co-Cr alloys due to the formation of numerical nano- sized wear debris from the …
-
Growth and Characterization of Magnesium Single Crystal for Biodegradable Implant Material Application
… Engineering Research Center for Revolutionizing Metallic Biomaterials (ERC-RMB) participant collaborators. They were tested for their biological behavior and compatibility.
-
The response of ASTM F1537 Co-28Cr-6Mo alloy with different phase constituents to low-temperature plasma carburising
Co-Cr alloys are the most widely used metallic biomaterials for metal-on-metal joint prostheses. However, concerns about increased revision rate associated with metal-on-metal replacements have been raised recently. This research was aimed at studying the response of medical grade ASTM Fl537 …
-
ADDITIVELY MANUFACTURED BETA–TI ALLOY FOR BIOMEDICAL APPLICATIONS
Metallic biomaterials have an essential portion of uses in biomedical applications. Their properties can be tuned by many factors resulting in their process tuneability. Among metallic biomaterials for biomedical and specifically orthopedic applications, titanium and its alloys exhibit the most …
-
COPPER-BASED SURFACE-ENGINEERED MATERIALS FOR BIOMEDICAL AND CATALYTIC APPLICATIONS
… design principles for optimizing engineered metallic biomaterials and oxide catalysts for demanding environments.</p>
-
Tin-Silver as a Novel Biodegradable Metallic Biomaterial
… tissue, documenting signs of degradation and metallic degradation products, then to characterize the electrochemical behavior of Sn-Ag in biologically representative environments and finally, to assess the biological interaction of Sn-Ag. Retrieval analyses developed successful methods, …
Page 1 of 3