Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"micro finite element"”
-
Development of a GPU Accelerated and Memory Efficient Finite Element Solv Element Solver for Micr er for Microstructur ostructural Analysis of Bone and P al Analysis of Bone and Porous Materials
Bone biomechanics can be simulated with micro finite element analysis in order to determine the mechanical response of bone to an applied load. However, the porous and heterogeneous nature of bone makes simulating it very difficult, as the high-resolution models required to accurately capture the …
-
Longitudinal assessment of mechanical strength of trabecular bone underlying bone marrow lesions following acute anterior cruciate ligament injuries.
… explores the strength of bone within BMLs using micro-finite element modeling based on MRI and HR-pQCT images throughout an 8- month period following an ACL tear. In the BML region in the injured knee, the bone strength decreased by 20.1% (P<0.001) at ~175 days post injury relative to the …
-
Trabecular Bone Adaptation: An Experimental And Computational Investigation
… properties are influenced by its complex microstructure which when disrupted, compromises bone function and increases fracture risk. This thesis explored trabecular bone adaptation to mechanical loading using ex vivo experimental and computational approaches. The effects of mesh density, …
-
Multi-scale models for the prediction of bone remodelling due to musculoskeletal interventions
… bone. The current research demonstrated that the micro-finite element (micro-FE) models used to calculate the strain distribution and, hence, predict the bone properties usually only investigate one loading condition. It is assumed that any load applied is axial to the bone, and hence, they ignore …
-
Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method
… quantitative computed tomography (HR-pQCT) and micro-finite element (FE) analysis provides important insight into bone health. Longitudinal analyses of bone morphology maximize precision by using 2D slice-matching registration (SM) or 3D rigid-body registration (3DR) to account for repositioning …
-
Short and Long Term Capacities of Slender Concrete Block Walls
… to eccentric axial loads were investigated. A finite element model was developed to include both the geometric and the material nonlinearities. To analyze large members, a combined macro-micro finite element model for the masonry assemblage was also developed by which the advantages of the …
-
Non-invasive prediction of bone mechanical properties of the mouse tibia in longitudinal preclinical studies
… preclinically. It can be monitored using in vivo micro-Computed Tomography (microCT) imaging in order to track longitudinal changes in its morphometric and densitometric properties. Additionally, microCT images can be converted into micro-Finite Element (microFE) models for the non-invasive …
-
Mapping Trabecular Bone Fabric Tensor by in Vivo Magnetic Resonance Imaging
… and internal (e.g. hormonal changes) stimuli. Micro magnetic resonance imaging (µMRI) has emerged as a non-invasive and non-ionizing method well-suited for the repeated measurements necessary for monitoring changes in bone integrity. However, in vivo image-based directional dependence of …
-
Multiscale methods for Stokes flow in heterogeneous media
… of a computation, depends strongly on the porous micro structure. Resolving the micro structure in the whole porous medium can, however, be prohibitive. Novel numerical methods that efficiently approximate the effective flow but resolve only a carefully selected reduced portion of the porous …
-
Characterization of Cortical Bone in Osteogenesis Imperfecta
… a paucity of data on macroscopic properties and microstructural metrics as well as limited correlation analyses performed between them within OI and healthy pediatric populations. Further, a micro-finite element (FE) model of human OI cortical bone has not been reported in the literature. This …
-
The Ability of Bone Mineral Density and Microstructural Indices to Reflect Mechanical Properties of Trabecular Bone
… to (1) apply high-resolution imaging techniques (micro-CT imaging) in combination with new computer modeling techniques (FEA) to quantify 3D microstructural and biomechanical properties of trabecular bone in the intertrochanteric region (2) investigate contribution of bone mineral density (BMD) …
-
Relating cortical bone mechanics to intracortical pore morphology, distribution and remodeling history within the fibula diaphysis
… and sectioned for histology. Three-dimensional micro-finite element models of each specimen were tested in compression using a linearly elastic analysis, and the SED of the bone immediately surrounding the pores was calculated within a plane of interest corresponding to the histological …
-
Stress Transmission in a Granular System
… stresses in each individual grain, termed micro Finite Element (μFE) model. The fabric of a natural sand obtained from the micro computed tomography (μCT) is virtualised to simulate the mechanical response of the material. The grain-to-grain interactions under loading are modelled in a …
-
Modelling the mechanical behaviour of the interface between prosthesis and bone
… have been developed for evaluation of the microstructural behaviour of the cement-bone interface. The first technique used a unit cell as a simplification of the morphology of cancellous bone. Using this method, variations in volume fraction resulting from changes in trabecular thickness …
-
Validation of an in vivo model for monitoring trabecular bone quality changes using finite element analysis.
… of three techniques – high resolution micro computed tomography (micro CT) scanning, Archimedes-based volume fraction measurement and serial sectioning or milling – were used to determine the volume fraction, trabecular thickness, trabecular separation, trabecular number and micro …
-
A patient-specific numerical musculoskeletal knee model : application to patellar resurfacing in Total Knee Arthroplasty
… The identification/validation was achieved by micro finite element (µFE) mechanical testing on fresh-frozen cadaveric patellar samples. As expected, anisotropy hypothesis provided more accurate stiffness, strain and stress predictions than isotropy one. After TKA, the patella model revealed a …
-
Development of a Bisphosphonate Delivering Hydrogel for the Augmentation of Impaired Peri-Implant Bone
… is characterized by a deterioration of the bone microarchitecture and a significant loss of bone mass, is affecting a rising number of mostly elderly patients. The main clinical consequences are typical fragility fractures resulting in severe pain, morbidity, and mortality for affected patients. …
-
Quality factors at the material and structural level that affect the toughness of human cancellous bone
… first is an investigation into the ability of micro-Computed Tomography (µCT) to assess the structural and density properties of bone tissue. This is achieved by imaging samples from the full spectrum of bone porosities, made possible by excision of an elephant femur, to assess the best methods …
-
Biomechanical Aspects of Osteogenesis in Load-Bearing Tissue Engineering Scaffolds
… rats. in vivo data are obtained by longitudinal micro-CT scanning of the animals. Having identified the three parameters, the model is validated by predicting the course of bone formation in two previously published in vivo studies. We find the predicted values to be consistent with the …