Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 36 for “"micro total analysis system"”
-
Development of micro total analysis system for detection of water pathogens
… method for detection of water pathogen using micro-total analysis system. Our system consisted of a micro-polymerase chain reaction (PCR) chip integrated with a continuous-flow microarray. Both of our micro-PCR chip and microarray were silicon/glass hybrid biochip fabricated based on …
-
Development of a PDMS Based Micro Total Analysis System for Rapid Biomolecule Detection
The emerging field of micro total analysis system powered by microfluidics is expected to revolutionize miniaturization and automation for point-of-care-testing systems which require quick, efficient and reproducible results. In the present study, a PDMS based micro total analysis system has been …
-
Contribution au développement d'un microsystème d'analyse, intégrant pré-concentration ionique par micro-électrodialyse et détection électrochimique sur diamant dopé au bore.
… d'un système portatif et intégré de type µTAS (micro-Total Analysis System) pour le traitement (préconcentration et simplification) de solution aqueuses contenant des métaux lourds et leur analyse en ligne. Pour la préconcentration amont, l'étude a porté sur la réalisation d'un …
-
A BIOPARTICLE SEPARATION TECHNIQUE THROUGH MICROCHANNELS USING SEQUENTIAL PRESSURE PULSES
… characterized in separating magnetic microspheres of 4.1 µm diameter from a suspension solution in DI water. µTAS (Micro Total Analysis System) frequently need to deal with bioparticle suspensions in solution. Separation of certain bioparticles is often desirable. Traditionally, …
-
Mems based bead size selection method for the electronic taste chip
A micromachined biological and chemical sensor array has been developed for the rapid characterization of multiple analytes in solution. Various biochemical and chemical sensors are loaded in small micromachined structure together to analyze the ingredients in the fluid. Each sensors give unique …
-
BIOPARTICLE SEPARATION IN NON-NEWTONIAN FLUID USING PULSED FLOW IN MICRO-CHANNELS
Micro Total Analysis System (µTAS) devices frequently need to deal with bio-particle suspensions in solution and separation of certain bio-particles is often desirable. Separation of plasma from the whole blood has become increasingly popular in clinical diagnostics. Using a finite volume method, …
-
An Integrated Polymer Based Polymerase Chain Reaction And Capillary Electrophoresis System For Genetic Diagnosis
Micro-Total-Analysis-Systems (µTAS) for genetic diagnosis have a great potential to revolutionize the future of health care. However the lack of µTAS, which is fully integrated, mass-producible and application oriented, has delayed µTAS development in real life application. In this work, I …
-
Development of a Composite ion-exchange membrane for PDMS-based microfluidic devices
… into a polydimethylsiloxane Lab-on-a-Chip or Micro-Total-Analysis-System. The majority of microfluidic membranes are based on creating microporous structures, because it allows flexibility in the choice of material such that it can match the material of the microfluidic chip. This cohesion …
-
Modeling, simulation, and fabrication of a PZT valveless micropump
<p>A micropump is one of the most important elements in a micro-total analysis system used for rapid chemical and biological analysis. To date, different kinds of micropumps have been designed, fabricated, tested, and implemented. Among them, a PZT valveless micropump is receiving increasing …
-
Two-Dimensional and High-Throughput Electrophoretic Separation of Proteins Using Polymeric Microchips
… digestion of the proteins. For 2-D separations, microfluidic devices are superior to bench top and capillary-based systems since they potentially provide higher separation efficiencies due to the minimal dead volumes produced during peak transfer between the two separation dimensions. In …
-
Development of Integrated Dielectric Elastomer Actuators (IDEAS): trending towards smarter and smaller soft microfluidic systems
During the last five years, great advancements in microfluidics have been achieved with the development of “sample-in-answer-out” systems. Such systems have begun to realize the true potential of analytical miniaturization since the concept of the “micro-Total Analysis System” was first envisioned. …
-
Development of Fluorous Solid-Phase Extraction (FSPE) on a Microchip and its Application to Proteomics
… phase was transplanted from the capillary to a microchip format. This microchip exhibits the merits of both selective fluorous interaction and micro total analysis system (µTAS).
-
Derivatization at Ultratrace Levels on Solid Phase Sorbents
… applied to a 2.1 × 10.0 mm guard column and on a microchip format in conjunction with analysis by HPLC. Both techniques provide an improvement in the reaction efficiency and mass detection limit. The analytes of interest are primary amines and they are derivatized with 5-fluorescein isothiocyanate …
-
Microfabrication and Evaluation of Planar Thin-Film Microfluidic Devices
Over the past 15 years, research in the field of microfluidics has rapidly gained popularity. By seeking to miniaturize and automate separation-based analysis, microfluidic research seeks to improve current methods through decreased cost, analysis time, and sources of contamination. My work has …
-
Manipulation and extraction of genomic DNA using functionalized magnetic particles for applications in microchip based bioanalysis
… known to be a bottle-neck step in an integrated micro-Total-Analysis-System (μTAS). Furthermore, the ability to manipulate and transport magnetic beads linked DNA materials by external magnetic force enable the movement of DNAs to different microreaction chambers for various …
-
A Customer Programmable Microfluidic System
Microfluidics is both a science and a technology offering great and perhaps even revolutionary capabilities to impact the society in the future. However, due to the scaling effects there are unknown phenomena and technology barriers about fluidics in microchannel, material properties in microscale …
-
Integrating Micro-Scale Separations to Matrix Assisted Laser Desorption and Ioniation Time of Flight Mass Spectrometry (MALDI-TOF-MS) for Protein Analysis
This dissertation describes the integration of micro-scale separations to matrix assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI TOF MS) for protein analysis. MALDI MS provides unsurpassed accurate mass measurements of intact bio-molecules, for example peptides and …
-
Integrated motor protein based nanodevices for biomolecular transport
… at nanoscale, which is pursued in fields of Micro total analysis system (&mgr;-TAS) or lab-on-a-chip. Due to unique mechanical functions performing micro/nano transport with high efficiency of the chemo-mechanical energy conversion in cells, motor proteins have been emphasized to perform …
-
Development Of A Miniaturized Electrochemical Pathogen Detection Platform For Micro-Total Analysis Systems
… but can also be integrated into a complete micro-total analysis system. The design incorporated a microfabricated liposome-amplified biosensor, a potentiostat for electrochemical tests, a liquid crystal display, a pushbutton interface for user input, memory for data storage and a serial …
Page 1 of 2