Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 121 for “"micro-CT imaging"”

  1. Development, Assessment, and Applications of Novel Micro-CT Imaging Devices

    <p>Preclinical imaging plays an essential role in biomedical research. Among availablemodalities, micro-computed tomography (micro-CT) offers high spatial resolution with relatively high throughput making it valuable for structural and functional imaging in small animals. However, traditional …

    duke Repository record for Development, Assessment, and Applications of Novel Micro-CT Imaging Devices (opens in a new tab)

  2. Three-dimensional quantitative analysis of bone microvasculature in synchrotron micro-CT imaging

    … du sein provoquent non seulement des destructions osseuses, mais entrainent également la formation d'une vascularisation indésirable. L'angiogenèse tumorale est une prolifération nécessaire d'un réseau de vaisseaux sanguins qui fournit des nutriments et de l'oxygène et élimine les déchets. …

    star-france Repository record for Three-dimensional quantitative analysis of bone microvasculature in synchrotron micro-CT imaging (opens in a new tab)

  3. Translation of micro-CT imaging into a 3D bio printable bone model

    … ex-vivo murine bones imaged by high resolution micro-computed tomography into a three-dimensional bio printable in-vitro bone model to reflect ex-vivo morphometry. Including, the associated characterisation of the model compared to native in-vivo murine bone and traditional monolayer culture …

    sheffield-hallam Repository record for Translation of micro-CT imaging into a 3D bio printable bone model (opens in a new tab)

  4. Dynamic Loading Of Anatomically Shaped Meniscal Constructs Generated Via Mri And micro-Ct Imaging

    … media and dynamic compression enhances the production of extracellular matrix (ECM) and mechanical properties of tissue-engineered (TE) constructs seeded with articular chondrocytes. Very few studies have attempted to engineer a whole meniscus and none have attempted to dynamically stimulate this …

    cornell Repository record for Dynamic Loading Of Anatomically Shaped Meniscal Constructs Generated Via Mri And micro-Ct Imaging (opens in a new tab)

  5. Structure-property relations of porcine trabecular bone and micro-CT imaging of various materials

    This thesis addresses the characterization of materials with a focus on trabecular bone. In the first part, we aim to find relations between morphological measures of trabecular bone and its Young’s modulus and ultimate compressive strength. Previous research has showed that apparent density and …

    uiuc Repository record for Structure-property relations of porcine trabecular bone and micro-CT imaging of various materials (opens in a new tab)

  6. An Investigation of Rat Vertebra Failure Behaviour Under Uniaxial Compression Through Time-Lapsed Micro-CT Imaging

    Osteoporosis is a bone degenerative disease characterized by reduced bone mass, quality and strength, along with changes in microarchitecture and increased incidence of fracture. The significant economic and social costs associated with osteoporotic fractures of the hip and spine have resulted in …

    queens Repository record for An Investigation of Rat Vertebra Failure Behaviour Under Uniaxial Compression Through Time-Lapsed Micro-CT Imaging (opens in a new tab)

  7. Utility of the Visible Heart® and Micro-CT Imaging to Optimize the Treatments of Bifurcation Stenting

    … This allows for novel uses of multimodal imaging for assessing/testing previous, current and future clinical recommendations for bifurcation techniques, without risking a living patient. After performing such procedures, high resolution 3D models were obtained via micro-CT imaging, which …

    umn Repository record for Utility of the Visible Heart® and Micro-CT Imaging to Optimize the Treatments of Bifurcation Stenting (opens in a new tab)

  8. Radiomics of Bone Analysis in Micro-CT Imaging with FDK Reconstruction and Modified Simultaneous Algebraic Reconstruction Technique

    Micro-CT provides high resolution image of small objects that can be used in various applications. One of the significant advantages of micro-CT lies in high sensitivity to bone structure. With micro-CT images, the degradation of bone structure induced by chronic kidney disease (CKD) being …

    buffalo Repository record for Radiomics of Bone Analysis in Micro-CT Imaging with FDK Reconstruction and Modified Simultaneous Algebraic Reconstruction Technique (opens in a new tab)

  9. A Novel In Vivo Synchrotron Radiation Micro-CT Imaging Platform For The Direct Tracking Of Remodeling Events In Cortical Bone

    … life, bone tissue continuously alters its microarchitecture in response to microdamage and other stimuli through remodeling. Specialized cellular groupings, Basic Multicellular Units (BMUs), conduct remodeling through ‘coupling’ bone resorption to formation. Osteoclasts within a BMU’s …

    sask Repository record for A Novel In Vivo Synchrotron Radiation Micro-CT Imaging Platform For The Direct Tracking Of Remodeling Events In Cortical Bone (opens in a new tab)

  10. Experimental investigation of two-phase flow properties of small core samples

    … samples having different scales ranging from micro-CT imaging to conventional core plug scales. Advances in micro-CT imaging of porous materials provide the opportunity to extract representative networks from the images. This improves the predictive capability of porescale network models to …

    unsw Repository record for Experimental investigation of two-phase flow properties of small core samples (opens in a new tab)

  11. Cost-effective non-destructive testing of biomedical components fabricated using additive manufacturing

    … medical components using additive manufacturing (AM). These novel components have the potential to improve clinical outcomes in various medical scenarios. However, AM introduces stability and repeatability concerns, which are potential roadblocks for its widespread use in the medical …

    uwo Repository record for Cost-effective non-destructive testing of biomedical components fabricated using additive manufacturing (opens in a new tab)

  12. Image-based characterization of low-plastic silt matrix for fabric quantification using x-ray micro computed tomography

    … from laboratory element testing research conducted at the University of British Columbia has shown the significant effect of particle structure (fabric) on the monotonic and cyclic shear behavior of silty soils, alongside the well-known impacts from factors such as void ratio and confining …

    ubc Repository record for Image-based characterization of low-plastic silt matrix for fabric quantification using x-ray micro computed tomography (opens in a new tab)

  13. Development and Assessment of a Micro-CT Based System for Quantifying Loaded Knee Joint Kinematics and Tissue Mechanics

    … anterior cruciate ligament (ACL) reconstruction is a highly developed surgical procedure, sub-optimal treatment outcomes persist. This can be partially attributed to an incomplete understanding of knee joint kinematics and regional tissue mechanic properties. A system for minimally-invasive …

    uwo Repository record for Development and Assessment of a Micro-CT Based System for Quantifying Loaded Knee Joint Kinematics and Tissue Mechanics (opens in a new tab)

  14. Development of micro-computed tomography for human fetal post-mortem imaging

    … loss during pregnancy. However, parents are reluctant to consent to an invasive autopsy. Modern imaging techniques can offer a non-invasive solution, but most current clinical techniques are unable to offer adequate image resolution for early gestation miscarriages, typically below 20weeks …

    ucl Repository record for Development of micro-computed tomography for human fetal post-mortem imaging (opens in a new tab)

  15. Using in vivo respiratory-gated micro-computed tomography imaging to monitor pulmonary side effects in 10 MV FLASH and conventional radiotherapy

    This study demonstrated a method that can characterize the development of FLASH and conventional radiotherapy-induced pulmonary complications with in vivo respiratory-gated micro-CT imaging methods in free-breathing mice. Thirty C57BL/6 mice were selected for this research project. Baseline …

    ubc Repository record for Using in vivo respiratory-gated micro-computed tomography imaging to monitor pulmonary side effects in 10 MV FLASH and conventional radiotherapy (opens in a new tab)

  16. High Temporal and Spatial Resolution - Combined Positron Emission Tomography and Micro-Computed Tomography Imaging in Core Analysis

    … process in porous systems, being a complex function of multiple physical properties of associated solids, fluids and flow conditions, is of vital importance. This thesis employs imaging techniques enabling detection of the process in 3D and with fine time resolution to provide key benefits in …

    unsw Repository record for High Temporal and Spatial Resolution - Combined Positron Emission Tomography and Micro-Computed Tomography Imaging in Core Analysis (opens in a new tab)

  17. Time course study of novel contrast agents MVivo AuNH₂ and Fenestra HDVC and their ability to monitor liver tumor growth

    Micro-computed tomography (micro-CT) imaging has been used to study anatomical features in experimental subjects, including small animals. To improve the visibility of organs and soft tissues, contrast agents (CAs) were developed. This created opportunities for studying disease progression through …

    ubc Repository record for Time course study of novel contrast agents MVivo AuNH₂ and Fenestra HDVC and their ability to monitor liver tumor growth (opens in a new tab)

  18. The Role of Osteopontin in Postnatal Vascular Growth: Functional Effects in Ischemic Limb Collateral Vessel Formation and Long Bone Fracture Healing

    … process involving multiple cells types whose functionality is orchestrated by a variety of soluble extracellular growth factors, mechanical stimuli, and matrix derived cues. The central goal for this dissertation project was to elucidate the role of osteopontin, a non-collagenous extracellular …

    gatech Repository record for The Role of Osteopontin in Postnatal Vascular Growth: Functional Effects in Ischemic Limb Collateral Vessel Formation and Long Bone Fracture Healing (opens in a new tab)

  19. Investigation of Rock-Fluid Interactions in Carbonate Reservoirs with the Use of Digital Rock Physics

    … into the mechanisms governing the interactions between water, oil and carbonate rocks using a series of core-flood experiments coupled with micro-CT imaging. Firstly, rock-fluid interactions leading to wettability alteration by seawater (injected in the secondary mode) and modified …

    unsw Repository record for Investigation of Rock-Fluid Interactions in Carbonate Reservoirs with the Use of Digital Rock Physics (opens in a new tab)

Page 1 of 7