Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"micro-coil"”

  1. Development of New Micro-coil Technologies for Environmental NMR Research

    … method is to decrease the size of the detection coil to a size similar to the mass-limited sample. These miniaturized detectors (commonly referred to as “microcoil technology”) have been demonstrated to enhance the mass-sensitivity of NMR spectroscopy, allowing for the analysis of a single …

    toronto-retro Repository record for Development of New Micro-coil Technologies for Environmental NMR Research (opens in a new tab)

  2. Design of CMOS Neural Probes Utilizing Micro-coil Magnetic Neurostimulation

    … of neural activity. Latest developments in micro-magnetic technology have shown that magnetic stimulation from micro-coil-based neural probes is capable of modulating neural behavior while circumventing the limitations of implantable electrodes. This is due to the induced electric fields …

    cornell Repository record for Design of CMOS Neural Probes Utilizing Micro-coil Magnetic Neurostimulation (opens in a new tab)

  3. Mini/micro coil design and optimization for wearable and implantable magnetic stimulation

    … urgent need of development. As new specialized coils are considered to be key factors for the future development of the next-generation magnetic stimulation methods. Novel coil design and efficient manufacturing will significantly accelerate the development of this field. For invasive magnetic …

    glasgow Repository record for Mini/micro coil design and optimization for wearable and implantable magnetic stimulation (opens in a new tab)

  4. Nonlinear vibration energy harvesters for powering the internet of things

    … silicon spring structure and double-layer planar micro-coils. A magnetic repulsion induced frequency tuning mechanism was incorporated in the prototype, and it was demonstrated that both linear and nonlinear hysteretic frequency responses could be tuned (by upto 18.6%) to match various ambient …

    cork Repository record for Nonlinear vibration energy harvesters for powering the internet of things (opens in a new tab)

  5. Magnetization reversal dynamics in magnetically coupled trilayer systems

    … circular dichroism and photoelectron emission microscopy was used to investigate the magnetic domain structure with element selectivity. In addition, a micro-coil, which can supply ns-short magnetic field pulses, was employed to study either the magnetic domain evolution induced by single …

    fu-berlin Repository record for Magnetization reversal dynamics in magnetically coupled trilayer systems (opens in a new tab)

  6. Deep brain stimulation through engineered micro-coils

    … explored the feasibility of employing spiral micro-coils for magnetic neurostimulation, utilising both computational methods, employing the finite element method in COMSOL Multiphysics and Sim4Life software platforms, and experimental micro-coils fabrication studies. Simulations were run at a …

    glasgow Repository record for Deep brain stimulation through engineered micro-coils (opens in a new tab)

  7. A 2-D micro-magnetic neuro-stimulation platform

    … in-vitro neuro-stimulation tool based on the micro-scale implementation of the transcranial magnetic stimulation (TMS) principle. The project involves the design, fabrication and testing of single coil geometries and a two dimensional array of micro-coils for establishing spatio-temporal …

    soton Repository record for A 2-D micro-magnetic neuro-stimulation platform (opens in a new tab)

  8. Η επίδραση της θρομβίνης στην αγγειογένεση σε πειραματικό μοντέλο εμφράγματος μυοκαρδίου σε κονίκλους

    … heart and distal coronary embolization with a micro-coil. This model of percutaneous transauricular myocardial ischemia in the rabbit wascompared with the gold standard of experimental myocardial infarction as induced by coronary ligation with a plain suture. The presented model avoids major …

    greece Repository record for Η επίδραση της θρομβίνης στην αγγειογένεση σε πειραματικό μοντέλο εμφράγματος μυοκαρδίου σε κονίκλους (opens in a new tab)

  9. Telemetric smart orthodontic brackets

    … field effect transistors (piezo-FETs), a microcoil for the real- ization of an inductive link and a reader unit for the telemetric readout. The piezo-FETs on the CMOS chip produce a voltage signal proportional to the applied mechanical in-plane normal stress, which is amplified and …

    freiburg-diss Repository record for Telemetric smart orthodontic brackets (opens in a new tab)

  10. Micro-capteurs implantables : étude des critères de performance en vue de l'optimisation des acquisitions par spectroscopie RMN in vivo

    … thèse est d’évaluer les performances des micro-antennes, en cas d’emploi en spectroscopie in vivo et de prévoir les éventuelles améliorations, tout en respectant les contraintes en termes d’encombrement et de biocompatibilité imposées par des applications cérébrales sur modèle animal. Par …

    star-france Repository record for Micro-capteurs implantables : étude des critères de performance en vue de l'optimisation des acquisitions par spectroscopie RMN in vivo (opens in a new tab) Restricted access

  11. Large Hybrid High Precision MEMS Mirrors

    This thesis presents the design and microfabrication technology of a tip-tilt, 2 degree of freedom "mirror system" made out of Silicon On Insulator (SOI) wafers with two movable mirrors that have diameter of 10 mm. The system was intended for precise beam steering applications and tracking for …

    epfl Repository record for Large Hybrid High Precision MEMS Mirrors (opens in a new tab)