  1. A Novel Metrology Standard for Synchrotron Produced Monochromatic X-ray Beams

    … and the characterization of radiation detectors. To facilitate the use of synchrotron-produced photons in such investigations, this project aims to determine the absorbed dose to water at depth for synchrotron-produced monochromatic x-ray beams with a standard uncertainty less than 1 %, …

    carleton Repository record for A Novel Metrology Standard for Synchrotron Produced Monochromatic X-ray Beams (opens in a new tab)

  2. Dosimetric Validation of an Electron Monte Carlo (eMC) Algorithm for Small Cutouts and Extended SSD’s: Assessing eMC in Small Field Dosimetry

    … Systematic measurements were performed using a microDiamond detector across various electron energies and field sizes. The study examines the discrepancies between measured and calculated (eMC) dose distributions, validating challenges due to lateral scatter disequilibrium and extended air gaps. …

    vcu Repository record for Dosimetric Validation of an Electron Monte Carlo (eMC) Algorithm for Small Cutouts and Extended SSD’s: Assessing eMC in Small Field Dosimetry (opens in a new tab)

  3. COMMISSIONING AND EVALUATION OF W2 PLASTIC SCINTILLATION DETECTORS FOR CLINICAL APPLICATIONS

    … receives the correct dose. Plastic scintillation detectors were introduced to address the shortcomings of older detectors for small field dosimetry. This study aims to determine the effects of varying dose rates on CLR values, commission the W2 PSD for clinical application, and investigate the …

    nus Repository record for COMMISSIONING AND EVALUATION OF W2 PLASTIC SCINTILLATION DETECTORS FOR CLINICAL APPLICATIONS (opens in a new tab) Download file for COMMISSIONING AND EVALUATION OF W2 PLASTIC SCINTILLATION DETECTORS FOR CLINICAL APPLICATIONS (opens in a new tab)

  4. Dosimetry at extreme non-charged particle equilibrium conditions using Monte Carlo and specialized dosimeters

    … can be measured indirectly by means of radiation detectors or dosimeters. The dose deposited in a detector can be related to dose deposited in a point within the patient. In theory, however, this is only possible under charged particle equilibrium (CPE). The motivation behind the dissertation was …

    uvic Repository record for Dosimetry at extreme non-charged particle equilibrium conditions using Monte Carlo and specialized dosimeters (opens in a new tab)

  5. Ανάπτυξη Monte Carlo προσομοιώσεων και δοσιμετρικών υπολογισμών σε σύγχρονα συστήματα γραμμικών επιταχυντών με ενσωματωμένο μαγνητικό τομογράφο (MR-Linacs)

    … y-axis, using four ionization chambers and the microDiamond detector. Regarding the x-axis profiles, a deviation of approximately 1.55mm from the central beam axis was observed for an ideal water detector, due to the Lorentz force. Positioning the ionization chamber parallel to the magnetic …

    greece Repository record for Ανάπτυξη Monte Carlo προσομοιώσεων και δοσιμετρικών υπολογισμών σε σύγχρονα συστήματα γραμμικών επιταχυντών με ενσωματωμένο μαγνητικό τομογράφο (MR-Linacs) (opens in a new tab)

  6. Dosimetric properties of a prototype high field parallel MRI-Linac

    … equipment and expertise. A method using a microDiamond detector to cross-calibrate an ion chamber between a conventional linac and MRI-linac was investigated in Chapter 6. Correction factors were measured on both a 1 T parallel MRI-linac and a 1.5 T perpendicular MRI-linac and showed good …

    unsw Repository record for Dosimetric properties of a prototype high field parallel MRI-Linac (opens in a new tab)

  7. Ανάπτυξη διαδικασιών και μεθόδων για τη ραδιοβιολογική μελέτη και τον ποιοτικό έλεγχο σύγχρονων τεχνικών ακτινοθεραπείας

    … of ionization chambers and dosimetry diodes, a microDiamond detector, TLDs, and alanine pellets using a comprehensive MC model of the GK Perfexion unit. Calculations were performed for the Solid Water (SW) and Acrylonitrile Butadiene Styrene (ABS) plastic phantoms, as well as for a water phantom …

    greece Repository record for Ανάπτυξη διαδικασιών και μεθόδων για τη ραδιοβιολογική μελέτη και τον ποιοτικό έλεγχο σύγχρονων τεχνικών ακτινοθεραπείας (opens in a new tab)