Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 60 for “"microbolometer"”.

  1. Silicon based uncooled microbolometer

    During the last decade, uncooled microbolometer infrared detectors have attracted the attention of military and civilian infrared detection and imaging industry due to their significant advantages. In actuality, infrared imaging systems play a critical role in sectors such as thermography …

    njit Repository record for Silicon based uncooled microbolometer (opens in a new tab)

  2. Uncooled Microbolometer Imaging Systems for Machine Vision

    Over the last 20 years, the cost of uncooled microbolometer-based imaging systems has drastically decreased while performance has increased. In the simplest terms, the figure of merit for these types of thermal detectors is given in terms of the τ-NETD product, the combination of the thermal time …

    ucf Repository record for Uncooled Microbolometer Imaging Systems for Machine Vision (opens in a new tab)

  3. Readout electronics for microbolometer infrared focal plane array

    Uncooled microbolometers suffer from the severe self-heating effect that will greatly affect the readout circuits. This project looks into a new self-heating cancellation technique and applies it to the readout integrated circuits (ROIC) for the microbolometer IR FPA. Such a cancellation scheme …

    nus Repository record for Readout electronics for microbolometer infrared focal plane array (opens in a new tab) Download file for Readout electronics for microbolometer infrared focal plane array (opens in a new tab)

  4. Electro-Thermal Mechanical Modeling of Microbolometer for Reliability Analysis

    … reliability. The electro-thermal analysis of a microbolometer pixel is critical to determine both device performance and reliability. To date, most microbolometer analysis research has focused on performance optimization and computation of thermal conductance directly from the geometry. However, …

    waterloo Repository record for Electro-Thermal Mechanical Modeling of Microbolometer for Reliability Analysis (opens in a new tab)

  5. Noise optimization of amorphous SixGeyO1-x-y uncooled microbolometer

    … oxide (SixGeyO1-x-y) uncooled infrared (IR) microbolometers has been performed. The experimental methods used to conduct the research are presented. The noise reduction was achieved by passivating SixGeyO1-x-y with Si3N4 layers and by annealing the devices in vacuum at 200 �C, 250 �C, or 300 …

    missouri Repository record for Noise optimization of amorphous SixGeyO1-x-y uncooled microbolometer (opens in a new tab)

  6. Enhancing microbolometer performance at terahertz frequencies with metamaterial absorbers

    … yet sensitive detectors such as uncooled microbolometers will be required. Metamaterials can improve THz absorption without significantly increasing the thermal mass or using exotic materials because their absorption is primarily dependent on the geometry of the materials and not their …

    nps Repository record for Enhancing microbolometer performance at terahertz frequencies with metamaterial absorbers (opens in a new tab)

  7. PSICE modelling and parametric study of microbolometer thermal detectors

    The operation of a bolometer thermal sensor is analogous to that of a charging capacitor in a generic RC circuit. As such, circuits containing bolometers can be analyzed with standard circuit simulation programs such as PSPICE. This thesis deals with the development of a bolometer model by using …

    nps Repository record for PSICE modelling and parametric study of microbolometer thermal detectors (opens in a new tab)

  8. Metasurface based uncooled Sixgeyo1-x-y microbolometer for infrared detection

    … metasurface integrated uncooled SixGeyO1-x-y microbolometers. Two device architecture were fabricated and characterized. The first design presents the implementation of metasurface integrated uncooled infrared (IR) silicon germanium oxide (Si-Ge-O) microbolometers for Long Wavelength Infrared …

    missouri Repository record for Metasurface based uncooled Sixgeyo1-x-y microbolometer for infrared detection (opens in a new tab)

  9. Spectroscopic imaging with uncooled microbolometer camera and step-scan FTIR

    … the feasibility of spectral imaging using a microbolometer infrared camera and a step-scan Fourier transform infrared spectrometer (FTIR). Spectral imaging is usually carried out using cryogenically cooled semiconductor based focal plane arrays (FPAs) which provide higher sensitivity compared …

    nps Repository record for Spectroscopic imaging with uncooled microbolometer camera and step-scan FTIR (opens in a new tab)

  10. Use of Ion Implantation in the Construction of an Uncooled Microbolometer

    Uncooled infrared (IR) bolometers have been constructed using a sensor bridge made of an electrically conductive polymer attached to a quartz substrate. The bridge is mounted on two sides and crosses an etched trough in the underlying substrate. Current is supplied to the bridge by means of two …

    mo-state Repository record for Use of Ion Implantation in the Construction of an Uncooled Microbolometer (opens in a new tab)

  11. Imaging of 3.4 THz quantum cascade laser beam using uncooled microbolometer camera

    … beam was imaged in real time using an uncooled microbolometer infrared camera typically used in far-infrared wavelength band (8-12 mm). The preliminary findings offer potential for development of a compact THz imaging system for applications involving concealed object detection.

    nps Repository record for Imaging of 3.4 THz quantum cascade laser beam using uncooled microbolometer camera (opens in a new tab)

  12. Terahertz imaging via a microbolometer camera under illumination of a quantum cascade laser

    … THz imaging using a 160x120 pixel FLIR A20M microbolometer camera designed to operate in long wave infrared range. The FTIR spectroscopy of the QCL beam revealed that lasing could be achieved at 2.85 and 2.91 THz frequencies depending on the bias current. This behavior was analyzed using the …

    nps Repository record for Terahertz imaging via a microbolometer camera under illumination of a quantum cascade laser (opens in a new tab)

  13. STUDY OF SELF-HEATING EFFECT OF MICROBOLOMETER INFRARED DETECTOR AND ITS COMPENSATION TECHNIQUE

    Microbolometer's self-heating effect during readout results in a degradation of the performance by requiring a large dynamic range of the preamplifier to be allocated for the signal due to self-heating. In this work, we have studied self-heating during the readout of microbolometer IR detectors and …

    nus Download file for STUDY OF SELF-HEATING EFFECT OF MICROBOLOMETER INFRARED DETECTOR AND ITS COMPENSATION TECHNIQUE (opens in a new tab)

  14. Patterned resistive sheets for potential use in 3D stacked multispectral reduced thermal mass microbolometer

    … further advantages to the functionality of the microbolometer. This study examines the potential of both single- and double-layer designs to achieve spectral selectivity in both broadband and narrowband absorption in the microbolometer's application. First, important design parameters, including …

    texas Repository record for Patterned resistive sheets for potential use in 3D stacked multispectral reduced thermal mass microbolometer (opens in a new tab)

  15. Analysis of 320X240 uncooled microbolometer focal plane array and design of thermoelectric cooler controller

    Uncooled microbolometer focal plane array is one of the promising method used in uncooled infrared imaging projects. The array's advantages over the conventional cooled imagers are its ability to operate without cryogenic cooler or dewar and its low cost. For the past several years, the ULTRA …

    njit Repository record for Analysis of 320X240 uncooled microbolometer focal plane array and design of thermoelectric cooler controller (opens in a new tab)

  16. Real-time terahertz imaging using a quantum cascade laser and uncooled microbolometer focal plane array

    … using an uncooled, 160x120 pixel infrared microbolometer camera and a milliwatt-scale quantum cascade laser (QCL). By replacing the camera's original focusing optics with a Tsurupica-based lens and minimizing diffraction effects incurred by the QCL output beam, an imaging scheme was …

    nps Repository record for Real-time terahertz imaging using a quantum cascade laser and uncooled microbolometer focal plane array (opens in a new tab)

  17. Real time imaging analysis using a terahertz quantum cascade laser and a microbolometer focal plane array

    … an uncooled vanadium oxide/silicon nitride based microbolometer. This thesis introduces an amorphous silicon based microbolometer with improved NETD in the 8-12 micrometer infrared spectral range. The QCL is usually operated in pulsed mode with rate in the hundreds of kHz which is much higher than …

    nps Repository record for Real time imaging analysis using a terahertz quantum cascade laser and a microbolometer focal plane array (opens in a new tab)

  18. Amorphous silicon germanium oxide (Si[sub]xGe[sub]yO[sub]1-x-y) thin films for uncooled infrared microbolometer

    … (Si-Ge-O) thin films for uncooled infrared (IR) microbolometers. Every object, whose temperature is more than absolute zero, radiates IR radiation. Uncooled infrared microbolometer can detect that IR radiation and can be used for thermal imaging. Such IR imaging cameras detect variations in heat …

    missouri Repository record for Amorphous silicon germanium oxide (Si[sub]xGe[sub]yO[sub]1-x-y) thin films for uncooled infrared microbolometer (opens in a new tab)

  19. Analysis and Modeling of Uncooled Microbolometers with Tunable Thermal Conductance

    Uncooled microbolometers have attracted significant interest due to their small size, low cost and low power consumption. As the application range of microbolometers broadens, increasing the dynamic range becomes one of the main objectives of microbolometer research. Targeting this objective, …

    waterloo Repository record for Analysis and Modeling of Uncooled Microbolometers with Tunable Thermal Conductance (opens in a new tab)

Page 1 of 3