Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 37 for “"microchannel plate"”.
-
Study on the Mechanism of Gain Drop in a Microchannel Plate
… Spatial Extent of the Transient Gain Drop in a Microchannel Plate. Mass Spectrometry 12, A0134 (2023); https://doi.org/10.5702/massspectrometry.A0134.
-
NUMERICAL MODELING AND OPTIMIZATION OF SINGLE PHASE MANIFOLD-MICROCHANNEL PLATE HEAT EXCHANGER
In recent years manifold-microchannel technology has received considerable attention from the research community as it has demonstrated clear advantage over state of the art heat exchangers. It has the potential to improve heat transfer performance by an order of magnitude while reducing pressure …
-
The use of a microchannel plate in the development of a chemical sensor
The use of a microchannel plate as an optical encoding device has many advantages. These include large surface area and large-scale signal averaging. This instrument was designed to obtain and interpret the information generated by the optical transform of a microchannel plate. It will be shown …
-
The search for tensor interactions in the beta-decay of polarized ⁸⁰Rb
… the ions towards a position sensitive microchannel plate and the electrons to another microchannel plate. The direction of polarization is parallel to the plates surface, so an asymmetry manifests itself as a difference in the distribution of ion impacts when the polarization is …
-
A detector upgrade for phase-imaging ion cyclotron resonance measurements at the CPT
A position-sensitive microchannel plate (MCP) detector has been installed at the Canadian Penning Trap (CPT) mass spectrometer located at the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne National Laboratory in order to carry out Phase-Imaging Ion Cyclotron Resonance …
-
A time-of-flight spectrometer for fission fragment identification
… shown improved efficiency (68%-70%) and sharper microchannel plate vs. surface barrier coincidence event time-resolution (6.38 ns) than previous, similar experiments.
-
Extreme Ultraviolet Polarimetry with Laser-Generated High-Order Harmonics
… positioning system that places harmonics on the microchannel plate detector with an accuracy of 0.3 mm, which allows a spectral resolution of about 180. We have demonstrated that reflectance as low as 0.2% can be measured at EUV wavelengths and that this data is repeatable to within the error of …
-
A measurement of the $e$-$\bar{\nu_e}$ angular correlation coefficient in the decay of $^6$He
… a multi-wire proportional chamber, and microchannel plate detectors. The analysis of the data and systematic uncertainties is conducted using a Monte-Carlo simulation. This dissertation describes the developments and calibrations for the electric field, the chamber and trap geometries, …
-
Data Processing Electronics for an Ultra-Fast Single-Photon Counting Camera
… computational platform built on an FPGA for a microchannel plate (MCP)-photomultiplier tube (PMT) based single-photon counting camera. Each photon is converted by the MCP-PMT into an electron cloud that generates current pulses across a 50×50 cross-strip anode. The Data Processing FPGA executes …
-
On the detection of two electrons in low-lying continuum states of a single projectile ion resulting from the collision of a 10.7 MeV AG4+ ion with an AR gas target
… the feasibility of using a large 30° parallel plate electrostatic analyzer to detect two electrons in low lying continuum states of a projectile ion. The two electrons are excited just above the double ionization threshold of a Ag<sup>q+</sup> projectile ion in a collision of a 0.1 MeV/u …
-
Design, optimisation and experimental validation of a soft X-ray Compton backscattering experiment at the AWAKE run 2 test injector
… an interaction chamber equipped with a movable microchannel plate Xray detector were installed. A measurement campaign was conducted to achieve precise temporal and spatial overlap of the electron and laser beams. Successful alignment resulted in the detection of a CBS signal, enabling …
-
A Low-Noise Lower-Power Charge Sensitive Amplifier for High-Rate Single-Photon Detection
… which are subsequently amplified through a microchannel plate (MCP) stack. The resulting charge is then deposited upon an anode and converted into a voltage by the CSA for digitization. The resolution of such a detector is linearly proportional to the noise of the CSA. The noise of the CSA …
-
Study of Electron-Impact Induced Fragmentation of Thymine
… time-of-flight mass spectrometer with a microchannel plate detector is used to detect and mass resolve the positively charged fragments. LabVIEW based data acquisition techniques are used to accumulate the time-of-flight data as a function of electron impact energy. The work described in …
-
Construction and calibration of a custom time-of-flight mass spectrometer and its use in measuring the reaction kinetics of transition metal ion-organic interactions.
… The revelatory hardware for our instrument is a microchannel plate detector (MCP). The MCP is mounted on the exit of a custom designed and built hemispherical energy analyzer (sector), which acts as an energy filter. This filtering characteristic of the sector permits study of selected ionized …
-
Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere
… mass range. However, due to its dependence on microchannel plate (MCP) detectors and high acceleration voltages, this technique has rarely been applied in the MLT. A new TOF-MS for making composition measurements of both charged and neutral particles in the upper atmosphere has been developed …
-
Resonance Enhanced Multiphoton Ionization Studies of Dichlorotoluenses, Dichloroanilines, and Dichlorophenols
… process and the sensitivity of a TOF-MF with a microchannel plate detector. A pulsed valve inlet system was tested to determine its effectiveness in “cooling” molecules but it was not used for the bulk of the studies performed. The instrument was tested using molecular and atomic bromine, atomic …
-
Enhancement of a Time-Of-Flight Mass Spectrometer Using a Bipolar Pulsed Electrostatic Particle Guide and a Novel MS-MS Correlation Technique
… a novel two-dimensional correlation technique. Microchannel plate detectors that are used with TOF-MS have been shown to be susceptible to saturation due to high ion influxes. Matrix assisted laser desorption ionization (MALDI), as used for this research, produces a large number of low molecular …
-
Low-Energy Electron Impact Fragmentations of the Polycyclic Aromatic Hydrocarbon Anthracene
… time-of-flight mass spectrometer with a microchannel plate detector is used to mass-resolve and detect the fragment ions. A multichannel scaler card is used for acquiring single mass spectra. Data acquisition is controlled by LabVIEW code, which ramps the electron impact energy from 0 to …
-
Developments for a measurement of the beta-nu correlation and determination of the recoil charge state distribution in 6He beta decay
… chamber, and the recoil ion is detected by a microchannel plate with delay-line anodes for position readouts. a_{beta-nu} is extracted by fitting the measured time-of-flight spectrum of the recoil ions to templates generated by Monte Carlo simulations. This dissertation describes the …
-
Design of control electronics for the Ram Energy Distribution Detector
… through the grid stack and detected by the microchannel plate, generating a function of current vs. voltage called an I-V curve. Traditionally, the size and power requirements of ram wind sensors has limited their use to larger satellites. In this thesis, the electrical design and basic …
Page 1 of 2